Fracture of Extended Stiffened End-Plate Moment Connections with Built-Up Beams

被引:0
|
作者
Eatherton, Matthew R. [1 ]
Murray, Thomas M. [1 ]
机构
[1] Virginia Tech, Blacksburg, VA 24061 USA
来源
PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, STESSA 2024 - VOL 1 | 2024年 / 519卷
关键词
Moment Resisting Frame; End-Plate Moment Connection; Fracture;
D O I
10.1007/978-3-031-62884-9_38
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the United States, there are three configurations of end-plate moment connection that are allowed for use in seismic special moment frames, two of which have stiffened end-plates extended beyond the beam flanges. Currently, built-up beam and column shapes are permitted for use with all three connection configurations. A series of nine experiments was conducted on extended end-plate moment connections to understand how the use of built-up beam shapes affected their fracture resistance and applicability for use in seismic applications. The beams, which were between 24 in. And 44 in. Deep, were either hot rolled beam shapes (four specimens), or built-up using plate and bar stock typical of-metal buildings (five specimens). Bolt patterns were varied from four bolts at each flange up to 12 bolts at each flange. The typical failure mode was fracture of the beam flange initiating at the toe of the end-plate stiffener, but a significant difference in deformation capacity was observed between specimens with hot-rolled and built-up beam shapes. When subjected to the AISC 341 SMF qualification displacement protocol, specimens with built-up beams failed at story drift ratios between 1.3% to 2.9% while specimens with hot-rolled beams survived through multiple cycles at 4% to 5% story drift ratio. Possible sources of the difference were investigated. Based on the findings, it is recommended that built-up beam sections not be used in extended stiffened end-plate moment connections for high seismic applications.
引用
收藏
页码:434 / 445
页数:12
相关论文
共 50 条
  • [21] END-PLATE MOMENT CONNECTIONS - THEIR USE AND MISUSE.
    Griffiths, John D.
    1600, (21):
  • [22] Structural behavior of end-plate bolted connections to stiffened columns
    Univ of Waterloo, Canada
    J Struct Eng, 8 (926-935):
  • [23] CYCLIC BEHAVIOR OF END-PLATE MOMENT CONNECTIONS - CLOSURE
    TSAI, KC
    POPOV, EP
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (03): : 877 - 877
  • [24] Effects of end-plate stiffener on behavior of extended end-plate beam-to-column connections
    Tong, Gen-Shu
    Zhao, Wei
    Sichuan Daxue Xuebao (Gongcheng Kexue Ban)/Journal of Sichuan University (Engineering Science Edition), 2006, 38 (04): : 39 - 43
  • [25] Behavior of steel beam to built-up box column moment connections with vertically stiffened panel zone
    Peykari K.
    Najafgholipour M.A.
    Journal of Building Pathology and Rehabilitation, 2023, 8 (1)
  • [26] Experimental investigation of sinus beams with end-plate connections
    Aydin, Abdulkadir Cuneyt
    Maali, Mahyar
    Kilic, Mahmut
    Sagiroglu, Merve
    THIN-WALLED STRUCTURES, 2015, 97 : 35 - 43
  • [27] Extended end-plate connections for replaceable shear links
    Ozkilic, Yasin Onuralp
    Topkaya, Cem
    ENGINEERING STRUCTURES, 2021, 240 (240)
  • [28] Calculation of end-plate strength in end-plate connections
    Design Institute, Hunan Univ., Changsha 410082, China
    不详
    Hunan Daxue Xuebao, 2008, 2 (13-16): : 13 - 16
  • [29] Modeling for moment-rotation characteristics for end-plate connections
    Shi, YJ
    Chan, SL
    Wong, YL
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (11): : 1300 - 1306
  • [30] Modeling for moment-rotation characteristics for end-plate connections
    Shi, Y.J.
    Chan, S.L.
    Wong, Y.L.
    Journal of structural engineering New York, N.Y., 1996, 122 (11): : 1300 - 1306