Fracture of Extended Stiffened End-Plate Moment Connections with Built-Up Beams

被引:0
|
作者
Eatherton, Matthew R. [1 ]
Murray, Thomas M. [1 ]
机构
[1] Virginia Tech, Blacksburg, VA 24061 USA
关键词
Moment Resisting Frame; End-Plate Moment Connection; Fracture;
D O I
10.1007/978-3-031-62884-9_38
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the United States, there are three configurations of end-plate moment connection that are allowed for use in seismic special moment frames, two of which have stiffened end-plates extended beyond the beam flanges. Currently, built-up beam and column shapes are permitted for use with all three connection configurations. A series of nine experiments was conducted on extended end-plate moment connections to understand how the use of built-up beam shapes affected their fracture resistance and applicability for use in seismic applications. The beams, which were between 24 in. And 44 in. Deep, were either hot rolled beam shapes (four specimens), or built-up using plate and bar stock typical of-metal buildings (five specimens). Bolt patterns were varied from four bolts at each flange up to 12 bolts at each flange. The typical failure mode was fracture of the beam flange initiating at the toe of the end-plate stiffener, but a significant difference in deformation capacity was observed between specimens with hot-rolled and built-up beam shapes. When subjected to the AISC 341 SMF qualification displacement protocol, specimens with built-up beams failed at story drift ratios between 1.3% to 2.9% while specimens with hot-rolled beams survived through multiple cycles at 4% to 5% story drift ratio. Possible sources of the difference were investigated. Based on the findings, it is recommended that built-up beam sections not be used in extended stiffened end-plate moment connections for high seismic applications.
引用
收藏
页码:434 / 445
页数:12
相关论文
共 50 条
  • [1] Demand on Stiffeners in Stiffened Extended End-plate Connections
    Zhao, W.
    Tong, G. S.
    ADVANCES IN STRUCTURAL ENGINEERING, 2012, 15 (08) : 1455 - 1469
  • [2] Seismic design of sixteen-bolt extended stiffened moment end-plate connections
    Mays, TW
    Sumner, EA
    Plaut, RH
    Murray, TM
    BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2000, : 727 - 733
  • [3] Cyclic Behavior of Bolted Extended End-Plate Moment Connections with Different Sizes of End Plate and Bolt Stiffened by a Rib Plate
    Haghollahi, Abbas
    Jannesar, Reza
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2018, 4 (01): : 200 - 211
  • [4] Experimental and theoretical analysis of the moment-rotation behaviour of stiffened extended end-plate connections
    Shi, Yongjiu
    Shi, Gang
    Wang, Yuanqing
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (09) : 1279 - 1293
  • [5] Moment-rotation relationship for extended end-plate connections
    Osman, A.
    Ghobarah, A.
    Korol, R.M.
    Proceedings - Annual Conference and 1st Biennial Environmental Speciality Conference, 1990, 4 pt 2
  • [6] Cyclic Response of Sloped Extended End-Plate Moment Connections
    Sun, Guohua
    Li, Zhiqin
    Fang, Youzhen
    Lin, Jun
    Gong, Futao
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (03)
  • [7] Progressive Collapse Resistance of Bolted Extended End-Plate Moment Connections
    Samad Barmaki
    Mohammad R. Sheidaii
    Omid Azizpour
    International Journal of Steel Structures, 2020, 20 : 1165 - 1179
  • [8] Behavior of extended end-plate moment connections subject to cyclic loading
    Sumner, EA
    Murray, TM
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2002, 128 (04): : 501 - 508
  • [9] Progressive Collapse Resistance of Bolted Extended End-Plate Moment Connections
    Barmaki, Samad
    Sheidaii, Mohammad R.
    Azizpour, Omid
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2020, 20 (04) : 1165 - 1179
  • [10] An experimental study on end-plate moment connections
    Yorgun, C
    Bayramoglu, G
    Arda, TS
    Yardimci, N
    Büyüktaskin, HA
    Karaman, SG
    Vatansever, C
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON STEEL STRUCTURES OF THE 2000'S, 2000, : 89 - 94