Comparison of simplified bone-screw interface models in materially nonlinear μFE simulations

被引:0
|
作者
Stefanek, Pia [1 ]
Pahr, Dieter H. [1 ,2 ]
Synek, Alexander [1 ]
机构
[1] TU Wien, Inst Lightweight Design & Struct Biomech, Vienna, Austria
[2] Karl Landsteiner Univ Hlth Sci, Div Biomech, Krems An Der Donau, Austria
关键词
Micro finite element modelling; Materially-nonlinear explicit simulation; Bone-screw system; Bone-screw interface modelling; FINITE-ELEMENT-ANALYSIS; IMPLANT; STABILITY;
D O I
10.1016/j.jmbbm.2024.106634
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Micro finite-element (mu FE) simulations serve as a crucial research tool to assist laboratory experiments in the biomechanical assessment of screw anchorage in bone. However, accurately modelling the interface between bone and screw threads at the microscale poses a significant challenge. Currently, the gold-standard approach involves employing computationally intensive physical contact models to simulate this interface. This study compared nonlinear mu FE predictions of deformations, whole-construct stiffness, maximum force and damage patterns of three different computationally efficient simplified interface approaches to the general contact interface in Abaqus Explicit, which was defined as gold-standard and reference model. The mu CT images (resolution: 32.8 mu m) of two human radii with varying bone volume fractions were utilized and a screw was virtually inserted up to 50% and 100% of the volar-dorsal cortex distance. Materially nonlinear mu FE models were generated and loaded in tension, compression and shear. In a first step, the common simplification of using a fully-bonded interface was compared to the general contact interface, revealing overestimations of wholeconstruct stiffness (19% on average) and maximum force (26% on average), along with inaccurate damage pattern replications. To enhance predictions, two additional simplified interface models were compared: tensionally strained element deletion (TED) and a novel modification of TED (TED-M). TED deletes interface elements strained in tension based on a linear-elastic simulation before the actual simulation. TED-M extends the remaining contact interface of TED by incorporating neighboring elements to the contact area. Both TED and TED-M reduced the errors in whole-construct stiffness and maximum force and improved the replication of the damage distributions in comparison to the fully-bonded approach. TED was better in predicting whole-construct stiffness (average error of 1%), while TED-M showed lowest errors in maximum force (1% on average). In conclusion, both TED and TED-M offer computationally efficient alternatives to physical contact modelling, although the fully-bonded interface may deliver sufficiently accurate predictions for many applications.
引用
收藏
页数:13
相关论文
共 42 条
  • [21] Histological and histomorphometric analysis of the bone-screw interface in the mandibular body after using a 2.0-mm miniplate system: An experimental study in dogs
    dos Santos, Thiago Iafelice
    de Oliveira, Paulo Tambasco
    Rosa, Adalberto Luiz
    Barros, Valdemar Mallet da Rocha
    Papalexiou, Vula
    Sverzut, Cassio Edvard
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (11) : 2169 - 2175
  • [22] On the anatomical definition of arterial networks in blood flow simulations: comparison of detailed and simplified models
    Blanco, Pablo J.
    Mueller, Lucas O.
    Watanabe, Sansuke M.
    Feijoo, Raul A.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2020, 19 (05) : 1663 - 1678
  • [23] On the anatomical definition of arterial networks in blood flow simulations: comparison of detailed and simplified models
    Pablo J. Blanco
    Lucas O. Müller
    Sansuke M. Watanabe
    Raúl A. Feijóo
    Biomechanics and Modeling in Mechanobiology, 2020, 19 : 1663 - 1678
  • [24] Comparison of simplified heat transfer models and CFD simulations for molten salt external receiver
    Reyes Rodriguez-Sanchez, Maria
    Marugan-Cruz, Carolina
    Acosta-Iborra, Antonio
    Santana, Domingo
    APPLIED THERMAL ENGINEERING, 2014, 73 (01) : 993 - 1005
  • [25] Stress analysis in pedicle screw and bone interface by various contact models in scoliotic spine fixation
    Rusli, M.
    Dahlan, H.
    Sahputra, R. E.
    Bur, M.
    INTERNATIONAL CONFERENCE ON INNOVATION IN ENGINEERING AND VOCATIONAL EDUCATION 2019 (ICIEVE 2019), PTS 1-4, 2020, 830
  • [26] MICROSTRUCTURAL MODELS OF TRABECULAR BONE - COMPARISON OF CT-BASED FE MODELS
    Jirousek, O.
    Zlamal, P.
    ENGINEERING MECHANICS 2011, 2011, : 247 - 250
  • [27] Quantitative comparison of Taylor flow simulations based on sharp-interface and diffuse-interface models
    Aland, S.
    Boden, S.
    Hahn, A.
    Klingbeil, F.
    Weismann, M.
    Weller, S.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2013, 73 (04) : 344 - 361
  • [28] Critical comparison of collisionless fluid models: Nonlinear simulations of parallel firehose instability
    Jikei, Taiki
    Amano, Takanobu
    PHYSICS OF PLASMAS, 2022, 29 (02)
  • [29] Interface and model reduction for efficient explicit simulations - a case study with nonlinear vehicle crash models
    Fehr, Joerg
    Holzwarth, Philip
    Eberhard, Peter
    MATHEMATICAL AND COMPUTER MODELLING OF DYNAMICAL SYSTEMS, 2016, 22 (04) : 380 - 396
  • [30] Accuracy of osseointegrated screw-bone construct stiffness and peri-implant loading predicted by homogenized FE models relative to micro-FE models
    Synek, Alexander
    Ortner, Lukas
    Pahr, Dieter H.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 140