Wide-field swept-source optical coherence tomography angiography (SS-OCTA) in the assessment of retinal vessel density and thickness in 4-to 16-year-old myopic children

被引:0
|
作者
Mu, Jingyu [1 ,2 ,4 ,5 ]
Wei, Jing [1 ,2 ,4 ]
Geng, Haoming [1 ,2 ,4 ,5 ]
Yi, Wenhua [1 ,2 ,4 ,5 ]
Kang, Xingzi [1 ,2 ,4 ,5 ]
Wen, Juan [1 ,2 ,3 ,4 ,5 ]
Duan, Junguo [1 ,2 ,3 ,4 ,5 ]
机构
[1] Chengdu Univ TCM, Chengdu, Sichuan, Peoples R China
[2] Chengdu Univ TCM, Eye Coll, Chengdu, Sichuan, Peoples R China
[3] Chengdu Univ TCM, Ineye Hosp, 8 Xinghui West Rd, Chengdu 610000, Peoples R China
[4] Key Lab Sichuan Prov Ophthalmopathy Prevent & Cure, Chengdu, Sichuan, Peoples R China
[5] Retinal Image Technol & Chron Vasc Dis Prevent & C, Chengdu, Sichuan, Peoples R China
关键词
Myopia; Refractive error; SS-OCTA; Retinal thickness; Retinal vessel density; AXIAL LENGTH; REGIONAL-VARIATIONS; BLOOD-FLOW; MICROVASCULATURE; EYES; ASSOCIATION; OUTER;
D O I
10.1016/j.pdpdt.2024.104240
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To analyze the characteristics of macular retinal vessel density and thickness in children with myopia. Methods: A cross-sectional study was conducted. A total of 228 children aged 4 -16 years who visited the Ineye Hospital of Chengdu University of Traditional Chinese Medicine from September 2022 to November 2023 were included. Those with -0.5D < spherical equivalent (SE) < +2.0D were included in the non -myopia group (150 eyes), those with - 3.0D < SE < -0.5D were included in the low myopia group (246 eyes), and those with SE < - 3.0D were included in the moderate -to -high myopia group (60 eyes). All subjects underwent cycloplegic refraction, IOLmaster500, and Wide -field SS-OCTA (to exclude some peripheral retinal degeneration). Multiple linear regression analysis was used to analyze the correlation between macular ETDRS subfield of full retinal thickness (FRT), outer, inner retinal thickness (ORT, IRT), retinal vessel density (VD), deep and superficial retinal vessel density (DVD, SVD), and SE, axial length (AL). Results: There were statistically significant differences ( P < 0.05) in FRT in the central fovea (1 mm diameter)and perifovea (Diameter 3 to 6 mm) among the non -myopia group, low myopia group, and moderate -to -high myopia group. The three groups also showed statistically significant differences ( P < 0.05) in VD in the central fovea and parafovea with a diameter of 1 to 3 mm (except the lower part). In multiple linear regression analysis adjusted for gender and age, SE and AL were found to be correlated with FRT in all ETDRS regions (except the central fovea) ( P < 0.01), and SE and AL were correlated with IRT in the central fovea and perifovea, respectively ( beta range - 2.302 to 1.652; P < 0.05). SE and AL were also correlated with ORT in the parafovea and perifovea, respectively ( beta range -4.371 to -2.344; P < 0.05). AL was negatively correlated with VD in the central fovea and parafovea (except the inferior region) ( P < 0.05), as well as with DVD in all ETDRS regions ( beta range -1.314 to - 1.031; P < 0.05). AL was only negatively correlated with SVD in the parafoveal nasal region ( beta = -0.633, P < 0.05). Additionally, the correlation between AL and DVD, ORT was higher than that with SVD, IRT. Conclusion: The more severe the myopia, the longer the AL, the thinner the FRT in the perifovea, and the lower the VD in both the fovea and parafovea in children. In addition, DVD and ORT were more significantly correlated with AL, suggesting that they may be more closely related to the growth of AL.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Diurnal Variation in Choroidal Parameters Among Healthy Subjects Using Wide-Field Swept-Source Optical Coherence Tomography Angiography
    He, Guiqin
    Zhang, Xiongze
    Zhuang, Xuenan
    Zeng, Yunkao
    Chen, Xuelin
    Gan, Yuhong
    Su, Yongyue
    Zhang, Yining
    Wen, Feng
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (05):
  • [42] A normative database of wide-field swept-source optical coherence tomography angiography quantitative metrics in a large cohort of healthy adults
    Munsell, Mary K.
    Garg, Itika
    Duich, Margaret
    Zeng, Rebecca
    Baldwin, Grace
    Wescott, Hannah E.
    Koch, Thomas
    Wang, Kira L.
    Patel, Nimesh A.
    Miller, John B.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (07) : 1835 - 1859
  • [43] A normative database of wide-field swept-source optical coherence tomography angiography quantitative metrics in a large cohort of healthy adults
    Mary K. Munsell
    Itika Garg
    Margaret Duich
    Rebecca Zeng
    Grace Baldwin
    Hannah E. Wescott
    Thomas Koch
    Kira L. Wang
    Nimesh A. Patel
    John B. Miller
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 1835 - 1859
  • [44] Comparison of indocyanine green angiography and swept-source wide-field optical coherence tomography angiography in posterior uveitis (vol 9, 853315, 2022)
    Tian, Meng
    Zeng, Guodong
    Tappeiner, Christoph
    Zinkernagel, Martin S.
    Wolf, Sebastian
    Munk, Marion R.
    FRONTIERS IN MEDICINE, 2024, 11
  • [45] Changes in Retinal Vessel and Retinal Layer Thickness after Vitrectomy in Macula-off Retinal Detachment Using Swept-source Optical Coherence Tomography Angiography
    Shin, Yong Un
    Cho, Heeyoon
    Seong, Mincheol
    Hong, Eun Hee
    Kim, Doo Roo
    Kang, Min Ho
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [46] Different Scan Protocols Affect the Detection Rates of Diabetic Retinopathy Lesions by Wide-Field Swept-Source Optical Coherence Tomography Angiography
    Zhu, Ying
    Cui, Ying
    Wang, Jay C.
    Lu, Yifan
    Zeng, Rebecca
    Katz, Raviv
    Wu, David M.
    Eliott, Dean
    Vavvas, Demetrios G.
    Husain, Deeba
    Miller, Joan W.
    Kim, Leo A.
    Miller, John B.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 215 : 72 - 80
  • [47] Diagnostic Accuracy of Wide-Field Map from Swept-Source Optical Coherence Tomography for Primary Open-Angle Glaucoma in Myopic Eyes
    Kim, Yong Woo
    Lee, Jinho
    Kim, Jin-Soo
    Park, Ki Ho
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 218 : 182 - 191
  • [48] Compare Wide-field Swept-Source Optical Coherence Tomography Angiography with Ultra-wide Field Color Fundus Photo and Fluorescein Angiography for Detecting Diabetic Retinopathy Lesions
    Cui, Ying
    Zhu, Ying
    Wang, Jay
    Lu, Yifan
    Zeng, Rebecca
    Katz, Raviv
    Wu, David M.
    Vavvas, Demetrios G.
    Husain, Deeba
    Miller, Joan W.
    Kim, Leo A.
    Miller, John B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [49] Predicting Visual Outcomes in Central Retinal Vein Occlusion (CRVO) with Vascular Metrics and Non-Perfusion Area (NPA) Measured by Wide-Field Swept-Source OCT-Angiography (WF SS-OCTA)
    Martinez-Velazquez, Luis Antonio
    Baldwin, Grace
    Garg, Itika
    Cui, Ying
    Katz, Raviv
    Zeng, Rebecca
    Duich, Margaret
    Moon, Jade Yunkyung
    Vingopoulos, Filippos
    Wescott, Hannah
    Koch, Thomas
    Patel, Nimesh A.
    Wu, David M.
    Miller, John B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [50] Retinal Pigment Epithelial Changes on Wide-Field Fundus Autofluorescence and Swept-Source Optical Coherence Tomography Imaging After Successful Retinal Detachment Surgery
    Yau, Kenneth
    Martinez, Maria Gil
    Pastor, Salvador
    Antoniou, Yianna
    Ivanova, Tsveta
    Jalil, Assad
    Vallejo-Garcia, Jose Luis
    Charles, Stephen
    Mclaughlan, Rita
    Stanga, Paulo E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)