Use of an implantable loop recorder in different age groups to identify the cause of unexplained syncope

被引:0
|
作者
Ignataviciute, Egle [1 ,2 ]
Dzindzeletaite, Gabriele [1 ,3 ]
Puodziukynas, Aras [1 ,2 ]
Rinkuniene, Diana [1 ,2 ]
机构
[1] Lithuanian Univ Hlth Sci, Med Acad, Kaunas, Lithuania
[2] Hosp Lithuanian Univ Hlth Sci, Kaunas Clin, Dept Cardiol, Kaunas, Lithuania
[3] Hosp Lithuanian Univ Hlth Sci, Dept Family Med, Kaunas Clin, Kaunas, Lithuania
来源
FAMILY MEDICINE AND PRIMARY CARE REVIEW | 2024年 / 26卷 / 02期
关键词
cardiac arrhythmias; syncope; cardiovascular diagnostic techniques;
D O I
10.5114/fmpcr.2024.139027
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background. An implantable loop recorder (ILR) is a small subcutaneous electrocardiogram monitoring device that may be useful in the diagnosis of patients with recurrent syncope or palpitations, while initial examination is not diagnostic. Objectives. To analyze the use of an ILR in different age groups and identify its effectiveness in determining the cause of syncope. Material and methods. This single -center retrospective study included 51 patients who underwent ILR implantation at the Hospital of the Lithuanian University of Health Sciences Kaunas Clinics due to unexplained syncope between January 2015 and July 2022. Patients were divided into two groups according to age: younger (< 50 years, n = 26) and older (>= 50 years, n = 25). Results. The mean duration to diagnosis of arrhythmia -related syncope was 219 [105-995] days in the younger patients and 141 [30-452] days in the older patients ( p = 0.28). In younger patients, the diagnoses were sinus node dysfunction (SND) ( n = 3), complete atrioventricular (AV) block ( n = 1), and ventricular tachycardia (VT) ( n = 1), while in older patients - SND ( n = 4), complete AV block ( n = 2), fast supraventricular tachycardia (SVT) ( n = 1), and VT ( n = 1). In younger patients, 4 (80%) were offered a pacemaker and 1 (20%) an implantable cardioverter-defibrillator implantation, while in older patients, the recommendations were more heterogeneous: 6 (75%) were offered a pacemaker, 1 (12.5%) an catheter ablation, and 1 (12.5%) an electrophysiological study. The documented incidence of arrhythmia -related syncope was not statistically significant different between the groups (19.2% vs 32.0%, p = 0.30). Conclusions. An ILR is a useful instrument in determining the causes of recurrent unexplained syncope in different age groups.
引用
收藏
页码:188 / 192
页数:5
相关论文
共 50 条
  • [21] Usefulness of an Implantable Loop Recorder in Diagnosing Unexplained Syncope and Predictors for Pacemaker Implantation
    Lee, Sung Ho
    Kim, Tae-Hoon
    Oh, Yong-Seog
    Oh, Seil
    Choi, Jong-Il
    Kim, Jin-Bae
    Nah, Jong-Chun
    Im, Sung Il
    Kang, Ki-Woon
    Han, Seongwook
    Kim, June Soo
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2020, 35 (02)
  • [22] Diagnostic assessment of recurrent unexplained syncope with a new subcutaneously implantable loop recorder
    Seidl, K
    Rameken, M
    Breunung, S
    Senges, J
    Jung, W
    Andresen, D
    van Toor, A
    Krahn, AD
    Klein, GJ
    EUROPACE, 2000, 2 (03): : 256 - 262
  • [23] The Implantable Loop Recorder-An Important Addition to the Armentarium in the Management of Unexplained Syncope
    Shanmugam, Nesan
    Liew, Reginald
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2012, 41 (03) : 115 - 124
  • [24] High incidence of tachyarrhythmias detected by an implantable loop recorder in patients with unexplained syncope
    Schernthaner, Christiana
    Danmayr, Franz
    Altenberger, Johann
    Pichler, Maximilian
    Strohmer, Bernhard
    KARDIOLOGIA POLSKA, 2008, 66 (01) : 37 - 46
  • [25] Implantable loop recorder versus conventional diagnostic workup for unexplained recurrent syncope
    Solbiati, Monica
    Costantino, Giorgio
    Casazza, Giovanni
    Dipaola, Franca
    Galli, Andrea
    Furlan, Raffaello
    Montano, Nicola
    Sheldon, Robert
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (04):
  • [26] Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry
    Edvardsson, Nils
    Frykman, Viveka
    van Mechelen, Rob
    Mitro, Peter
    Mohii-Oskarsson, Afsaneh
    Pasquie, Jean-Luc
    Ramanna, Hemanth
    Schwertfeger, Frank
    Ventura, Rodolfo
    Voulgaraki, Despina
    Garutti, Claudio
    Stolt, Pelle
    Linker, Nicholas J.
    EUROPACE, 2011, 13 (02): : 262 - 269
  • [27] Diagnosis of a rare cause of arrhythmogenic syncope by means of an implantable loop recorder
    Berger, T
    Roithinger, FX
    Hintringer, F
    HEART, 2002, 88 (01) : 10 - 10
  • [28] Cochrane corner: implantable loop recorder versus conventional workup for unexplained recurrent syncope
    Solbiati, Monica
    Casazza, Giovanni
    Dipaola, Franca
    Sheldon, Robert S.
    Costantino, Giorgio
    HEART, 2016, 102 (23) : 1862 - 1863
  • [29] BUDGET IMPACT ANALYSIS OF DIAGNOSTIC OF UNEXPLAINED AND/OR RECURRENT SYNCOPE WITH APPLICATION OF IMPLANTABLE LOOP RECORDER
    Gwiosda, B.
    Palka, I
    Karas, D.
    Wladysiuk, M.
    Szmurlo, D.
    Rutkowski, J.
    Plisko, R.
    Rys, P.
    VALUE IN HEALTH, 2009, 12 (07) : A322 - A322
  • [30] Clinical Utility of a Novel Wireless Implantable Loop Recorder in the Evaluation of Patients with Unexplained Syncope
    Paruchuri, Vijayapraveena
    Adhaduk, Mehul
    Garikipati, Naga V.
    Steinberg, Jonathan S.
    Mittal, Suneet
    CIRCULATION, 2010, 122 (21)