Background MICRA implantation is not commonly done as a day-case procedure. Elective leadless pacemakers are implanted routinely in our centre. Objective To assess whether the day-case MICRA procedure is safe. Methods We retrospectively collected data from all patients undergoing elective MICRA implantation at our centre between May 2014 and Nov 2022 (n = 81). Two patient groups were stratified: those planned to be discharged on the same day (SD, n = 52) and those planned to be observed overnight after the procedure (ON, n = 29). Patient demographics, size of the sheath used, type of MICRA device, and rate of complications were recorded. In patients with successful implants (n = 80), device function at discharge and first routine follow-up were evaluated. Results There were 58% males in the SD group and 45% in the ON group. Median age was 49 years in the SD and 67 years in the ON. Among patients who were planned as a day case, 8 patients had to stay in the hospital but for < 48 h: 2 due to minor groin bleeding, 1 due to patient's request despite fit to discharge, 4 due to the procedure carried out later in the day, and 1 for observation due to procedural complexity. MICRA implantation was successful in 80 patients. The rate of the major complications was 2% in the SD group and 7% in the ON group (p = 0.223), and none of the co-morbidities assessed showed an association with any complications. Device parameters at the follow-up were available in 76 patients. The rate of patients with low and stable PCT at follow-up was also 98% in the SD group and 96% in the ON group. Conclusions Day case MICRA procedure can be performed safely in an appropriately selected patient population.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 50 条
  • [21] RENAL BIOPSY - A SAFE AND EASY DAY-CASE PROCEDURE
    JASSAL, V
    MUCSI, I
    MUSTATA, S
    ULDALL, PR
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1995, 6 (03): : 392 - 392
  • [22] Micra leadless pacemaker retrieval for broken tines: a case report
    Hu, Qingyun
    Chen, Keping
    Dai, Yan
    Zhang, Shu
    CLINICAL RESEARCH IN CARDIOLOGY, 2022, 111 (11) : 1295 - 1298
  • [23] A Rare Case of Persistent Bacteremia: Leadless Micra Pacemaker Endocarditis
    Patel, Himax
    Harrell, Sean
    Hreibe, Haitham
    Sharkawi, Musa
    AlJaroudi, Wael
    CASE REPORTS IN CARDIOLOGY, 2023, 2023
  • [24] Micra leadless pacemaker retrieval for broken tines: a case report
    Qingyun Hu
    Keping Chen
    Yan Dai
    Shu Zhang
    Clinical Research in Cardiology, 2022, 111 : 1295 - 1298
  • [25] DAY CASE PACEMAKER IMPLANTATION FEASIBLE ACCEPTABLE AND SAFE
    Brahmbhatt, D. H.
    Chari, A.
    Prasad, R.
    Nayar, V.
    Cantelon, P.
    Belham, M. R. D.
    Pugh, P. J.
    HEART, 2013, 99
  • [26] Day-case permanent pacemaker implantation is safe and cost effective: experience from a large UK tertiary centre
    Krishnamoorthy, S.
    Nadir, A.
    Mullin, P.
    Morley-Davies, A.
    Creamer, J.
    Osman, F.
    EUROPEAN HEART JOURNAL, 2008, 29 : 22 - 22
  • [27] Implantation of a leadless pacemaker in a patient after the Senning procedure-a case report
    Kowalska, Wiktoria
    Jedrzejczyk-Patej, Ewa
    Jagosz, Marta
    Kalarus, Zbigniew
    Sredniawa, Beata
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2021, 25 (04): : 278 - 279
  • [28] Percutaneous extraction of a leadless Micra pacemaker after dislocation: a case report
    Fichtner, Stephanie
    Estner, Heidi L.
    Naebauer, Michael
    Hausleiter, Jorg
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2019, 3 (03)
  • [29] Prevalence of new-onset tricuspid regurgitation after leadless Micra pacemaker implantation
    La Fazia, V.
    Gianni, C.
    Pierucci, N.
    Della Rocca, D. G.
    Mohanty, S.
    Torlapati, G.
    Al-Ahmad, A.
    Bassiouny, M.
    Gallinghouse, G. J.
    Horton, R.
    Burkhardt, J. D.
    Lakkireddy, D.
    Forleo, G. B.
    Di Biase, L.
    Natale, A.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [30] A simultaneous occurrence of pulmonary embolism and cerebral infarction following Micra™ leadless pacemaker implantation
    Li, Song-Hua
    Dong, Shao-Hua
    Kan, Tong
    Yue, Sun
    Li, Bo
    Lu, Yang
    Li, Pan
    Guo, Zhi-Fu
    JOURNAL OF GERIATRIC CARDIOLOGY, 2023, 20 (10) : 756 - 759