Design and Biocompatibility of a Novel, Flexible Artificial Cornea

被引:2
|
作者
Li, Gavin [1 ,2 ]
Aldave, Anthony J. [3 ]
Amescua, Guillermo [4 ]
Colby, Kathryn A. [5 ]
Cortina, Maria S. [6 ]
de la Cruz, Jose [6 ]
Parel, Jean-Marie A. [4 ]
Schmiedel, Thomas B. [7 ]
Akpek, Esen Karamursel [1 ]
机构
[1] Johns Hopkins Univ, Wilmer Eye Inst, Sch Med, Ocular Surface Dis Clin, 1800 Orleans St,Woods 372, Baltimore, MD 21287 USA
[2] Icahn Sch Med Mt Sinai, New York, NY USA
[3] Stein Eye Inst, David Geffen Sch Med, UCLA, Los Angeles, CA USA
[4] Univ Miami, Bascom Palmer Eye Inst, Miller Sch Med, Miami, FL USA
[5] New York Univ, Grossman Sch Med, Dept Ophthalmol, New York, NY USA
[6] Univ Illinois, Illinois Eye & Ear Infirm, Chicago, IL USA
[7] W L Gore & Associates Inc, Innovat Ctr Excellence, Newark, DE USA
来源
关键词
corneal transplantation; keratoprosthesis; biocompatibility; LIGHT TRANSMISSION; TRANSPLANTATION; OUTCOMES; TRENDS; DEVICE; EYE; KERATOPROSTHESES; COMPLICATIONS; KERATOPLASTY;
D O I
10.1167/tvst.13.5.19
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We sought to introduce the materials, design, and biocompatibility of a flexible and suturable artificial corneal device. Methods: Single-piece, fully synthetic, optic-skirt design devices were made from compact perfluoroalkoxy alkane. The skirt and the optic wall surfaces were lined with a porous tissue ingrowth material using expanded polytetrafluoroethylene. Full-thickness macroapertures around the skirt perimeter were placed to facilitate nutrition of the recipient cornea. Material properties including the skirt's modulus of elasticity and bending stiffness, optic light transmission, wetting behavior, topical drug penetrance, and degradation profile were evaluated. Results: The final prototype suitable for human use has a transparent optic with a diameter of 4.60 mm anteriorly, 4.28 mm posteriorly, and a skirt outer diameter of 6.8 mm. The biomechanical and optical properties of the device closely align with the native human cornea with an average normalized device skirt-bending stiffness of 4.7 kPa<middle dot>mm4 and light transmission in the visible spectrum ranging between 92% and 96%. No optical damage was seen in the 36 devices tested in fouling experiments. No significant difference was observed in topical drug penetrance into the anterior chamber of the device implanted eye compared with the na & iuml;ve rabbit eye. Conclusions: The flexibility and biocompatibility of our artificial cornea device may offer enhanced tissue integration and decreased inflammation, leading to improved retention compared with rigid keratoprosthesis designs.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Biocompatibility of biomaterials - Lessons learned and considerations for the design of novel materials
    Schmalz, Gottfried
    Galler, Kerstin M.
    DENTAL MATERIALS, 2017, 33 (04) : 382 - 393
  • [32] Artificial cornea: Myth or reality?
    Lagali, Neil
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [33] Development of an artificial corneal button for penetrating keratoplasty: Design, biocompatibility and results in animals
    Hicks, CR
    Chirila, TV
    Dalton, PD
    Clayton, AB
    Fitton, JH
    Ziegelaar, BW
    Vijayasekaran, S
    Crawford, GJ
    Constable, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 2524 - 2524
  • [34] Design and in Vitro Biocompatibility of a Novel Ocular Drug Delivery Device
    Gooch, Nathan
    Burr, Randon Michael
    Holt, Dolly J.
    Gale, Bruce
    Ambati, Balamurali
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2013, 4 (01): : 14 - 26
  • [35] In vivo study of the biocompatibility of a novel compressed collagen hydrogel scaffold for artificial corneas
    Xiao, Xianghua
    Pan, Shiyin
    Liu, Xianning
    Zhu, Xiuping
    Connon, Che John
    Wu, Jie
    Mi, Shengli
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2014, 102 (06) : 1782 - 1787
  • [36] Design of novel three-finger flexible microgripper based on artificial muscle-IPMC materials
    Peng, Hanmin
    Li, Huafeng
    Hui, Yao
    Ding, Qingjun
    Zhao, Chunsheng
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2010, 30 (04): : 347 - 352
  • [37] A Novel Flexible Experiment Design Method
    Zhai, Gang
    Ma, Yaofei
    Song, Xiao
    Wu, Yulin
    MODEL DESIGN AND SIMULATION ANALYSIS, 2016, 603 : 28 - 39
  • [38] DESIGN OF A NOVEL FLEXIBLE ENDOSCOPE - CARDIOSCOPE
    Li, Zheng
    Oo, Min Zin
    Nalam, Varun
    Vu Duc Thang
    Yu, Haoyong
    Ren, Hongliang
    Kofidis, Theodoros
    INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2015, VOL 5B, 2016,
  • [39] A novel method to design flexible URAs
    Lang, Haitao
    Liu, Liren
    Yang, Qingguo
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2007, 9 (05): : 502 - 505
  • [40] ARTIFICIAL-HEART - BIOCOMPATIBILITY
    HARASAKI, H
    GOLDING, L
    CURRENT OPINION IN CARDIOLOGY, 1988, 3 (05) : 770 - 775