Characterization of Electrochemical and Biocompatibility of Zinc Oxide Coating Electrodeposited on Commercial Pure Titanium Alloy

被引:0
|
作者
Torabianfard, Seyed Reza [1 ]
Jamaati, Roohollah [1 ]
Aval, Hamed Jamshidi [1 ]
机构
[1] Babol Noshirvani Univ Technol, Dept Mat Engn, Shariati Ave, Babol 4714871167, Iran
关键词
biomaterials; corrosion behavior; electrodeposition; pure titanium; zinc oxide; SPRAYED HA/ZNO COATINGS; CORROSION-RESISTANCE; SURFACE-PROPERTIES; ZNO; FILMS; ANTIBACTERIAL; NANOPARTICLES; MORPHOLOGY; SUBSTRATE; BEHAVIOR;
D O I
10.1002/adem.202302261
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study examines how the duration of electrodeposition affects the morphology and electrochemical characteristics of zinc oxide coatings applied to a pure titanium substrate. The morphology of the coating and the phases present within it are analyzed using a scanning electron microscope and the X-ray diffraction technique. The coating's resistance to corrosion in a phosphate-buffered saline solution is evaluated using two electrochemical methods: impedance spectroscopy and potentiodynamic polarization tests. The surface roughness of the coated samples is assessed using interferometry. The results demonstrate that an increase in electrodeposition time, ranging from 150 to 1200 s, leads to an enhanced texture intensity in the (0002) and (011<overline>$\bar{1}$0) planes of the ZnO coating. Furthermore, the thickness of the ZnO crystals and surface roughness increases by factors of 3.25 and 2.79, respectively, as the deposition time is extended. This extended duration results in the formation of larger needle-shaped and flower-like ZnO crystals, leading to a significantly nonuniform structure. Correspondingly, the corrosion rate also increases as the electrodeposition time is extended from 150 to 1200 s, rising from 0.001951 to 9.117 mu m year-1. The lowest corrosion rate (1.654 mu m year-1) is achieved in coatings deposited for 300 s using a potential of 3 V. Herein, the application of zinc oxide coatings for bone implant purposes is attracting significant interest. An examination is being conducted on how the electrodeposition time influences the electrochemical characteristics of zinc oxide coatings. A corrosion rate of 1.654 mu m year-1 is observed in coatings that are electrodeposited for 5 min using a potential of 3 V.image (c) 2024 WILEY-VCH GmbH
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Morphological and electrochemical characterization of electrodeposited calcium phosphate coating
    Rondelli, G.
    Testa, C.
    METALLURGIA ITALIANA, 2019, 111 (11-12): : 64 - 68
  • [12] Cyclic oxidation behavior and oxide scale adhesion of Al/NiCrAlY coating on pure titanium alloy
    Gong, Xue
    Chen, Ruirun
    Wang, Qi
    Wang, You
    Zhang, Nannan
    Zhang, Zhongli
    Fu, Hengzhi
    JOURNAL OF ALLOYS AND COMPOUNDS, 2017, 729 : 679 - 687
  • [13] Biocompatibility of a titanium-aluminum nitride film coating on a dental alloy
    Chung, KH
    Liu, GT
    Duh, JG
    Wang, JH
    SURFACE & COATINGS TECHNOLOGY, 2004, 188 (1-3 SPEC.ISS.): : 745 - 749
  • [14] ZINC OXIDE AND TITANIUM OXIDE IN A PROTEIN-LATEX COATING
    TAUTH, GG
    JONES, HC
    PAPIER, 1968, 22 (11): : 829 - &
  • [15] Electrophoretic coating of magnesium oxide on microarc-oxidized titanium and characterization of in vitro antibacterial activity and biocompatibility
    Du, Jiaheng
    Fan, Xinli
    Xiao, Dongqin
    Wang, Wuxiang
    Yin, Yiran
    Li, Zhong
    He, Kui
    Tan, Yanfei
    Yan, Jiyuan
    Liu, Gangli
    Duan, Ke
    SURFACE & COATINGS TECHNOLOGY, 2024, 476
  • [16] Biocompatibility of surface treated pure titanium and titanium alloy byin vivo andin vitro test
    Min -Ho Lee
    Dong -Joo Yoon
    Dae -Hee Won
    Tae -Sung Bae
    Fumio Watari
    Metals and Materials International, 2003, 9 : 35 - 42
  • [17] Electrochemical fabrication and biocompatibility of the hydroxyapatite coating on magnesium alloy for implanted applications
    Guan, Shaokang
    Peng, Li
    Wen, Cuilian
    Luo, Qun
    MAGNESIUM TECHNOLOGY 2008, 2008, : 367 - 371
  • [18] Coating of Ti-6Al-4V alloy with pure titanium film by sputter-deposition for improving biocompatibility
    Sonoda, T
    Saito, T
    Watazu, A
    Katou, K
    Asahina, T
    SURFACE AND INTERFACE ANALYSIS, 2006, 38 (04) : 797 - 800
  • [19] The relation between electrochemical tests and in vitro evaluation of titanium alloy biocompatibility
    Popa, M. V.
    Demetrescu, I.
    Iordachescu, D.
    Cimpean, A.
    Vasilescu, E.
    Drob, P.
    Vasilescu, C.
    Istratescu, M.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2007, 58 (09): : 667 - 675
  • [20] Preparation and Characterization of Titanium Alloy Protective Coating
    Liu Hao
    Chen Guangchao
    Du Lingzhong
    Lan Hao
    Huang Chuanbing
    Wang Binli
    Zhang Huiying
    Zhang Weigang
    RARE METAL MATERIALS AND ENGINEERING, 2018, 47 (02) : 647 - 651