Characterization of Electrochemical and Biocompatibility of Zinc Oxide Coating Electrodeposited on Commercial Pure Titanium Alloy

被引:0
|
作者
Torabianfard, Seyed Reza [1 ]
Jamaati, Roohollah [1 ]
Aval, Hamed Jamshidi [1 ]
机构
[1] Babol Noshirvani Univ Technol, Dept Mat Engn, Shariati Ave, Babol 4714871167, Iran
关键词
biomaterials; corrosion behavior; electrodeposition; pure titanium; zinc oxide; SPRAYED HA/ZNO COATINGS; CORROSION-RESISTANCE; SURFACE-PROPERTIES; ZNO; FILMS; ANTIBACTERIAL; NANOPARTICLES; MORPHOLOGY; SUBSTRATE; BEHAVIOR;
D O I
10.1002/adem.202302261
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study examines how the duration of electrodeposition affects the morphology and electrochemical characteristics of zinc oxide coatings applied to a pure titanium substrate. The morphology of the coating and the phases present within it are analyzed using a scanning electron microscope and the X-ray diffraction technique. The coating's resistance to corrosion in a phosphate-buffered saline solution is evaluated using two electrochemical methods: impedance spectroscopy and potentiodynamic polarization tests. The surface roughness of the coated samples is assessed using interferometry. The results demonstrate that an increase in electrodeposition time, ranging from 150 to 1200 s, leads to an enhanced texture intensity in the (0002) and (011<overline>$\bar{1}$0) planes of the ZnO coating. Furthermore, the thickness of the ZnO crystals and surface roughness increases by factors of 3.25 and 2.79, respectively, as the deposition time is extended. This extended duration results in the formation of larger needle-shaped and flower-like ZnO crystals, leading to a significantly nonuniform structure. Correspondingly, the corrosion rate also increases as the electrodeposition time is extended from 150 to 1200 s, rising from 0.001951 to 9.117 mu m year-1. The lowest corrosion rate (1.654 mu m year-1) is achieved in coatings deposited for 300 s using a potential of 3 V. Herein, the application of zinc oxide coatings for bone implant purposes is attracting significant interest. An examination is being conducted on how the electrodeposition time influences the electrochemical characteristics of zinc oxide coatings. A corrosion rate of 1.654 mu m year-1 is observed in coatings that are electrodeposited for 5 min using a potential of 3 V.image (c) 2024 WILEY-VCH GmbH
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Characterization and biocompatibility study of hydroxyapatite coating on the surface of titanium alloy
    Jiang, Jiawei
    Han, Gui
    Zheng, Xuesong
    Chen, Gang
    Zhu, Peizhi
    SURFACE & COATINGS TECHNOLOGY, 2019, 375 : 645 - 651
  • [2] Surface Characterization and Biocompatibility of Selenium-Doped Hydroxyapatite Coating on Titanium Alloy
    Yilmaz, Bengi
    Evis, Zafer
    Tezcaner, Aysen
    Banerjee, Sreeparna
    INTERNATIONAL JOURNAL OF APPLIED CERAMIC TECHNOLOGY, 2016, 13 (06) : 1059 - 1068
  • [3] Enhancing Antibacterial Performance and Biocompatibility of Pure Titanium by a Two-Step Electrochemical Surface Coating
    Yu, Sen
    Guo, Dagang
    Han, Jianye
    Sun, Lijuan
    Zhu, Hui
    Yu, Zhentao
    Dargusch, Matthew
    Wang, Gui
    ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (40) : 44433 - 44446
  • [4] Characterization of black chromate conversion coating on the electrodeposited zinc-iron alloy
    Long, ZL
    Zhou, YC
    Xiao, L
    APPLIED SURFACE SCIENCE, 2003, 218 (1-4) : 123 - 136
  • [5] Characterization of native and anodic oxide films formed on commercial pure titanium using electrochemical properties and morphology techniques
    Fadl-allah, Sahar A.
    Mohsen, Q.
    APPLIED SURFACE SCIENCE, 2010, 256 (20) : 5849 - 5855
  • [6] Investigation of porous pure titanium/titanium alloy coating brazed on titanium alloy surface
    Liang, Fang-Hui
    Li, Tong
    Chen, Bo
    Mao, Wei
    Huang, Yong-Ling
    Zhou, Xue-Yu
    Cailiao Gongcheng/Journal of Materials Engineering, 2010, (06): : 68 - 72
  • [7] Biocompatibility of surface treated pure titanium and titanium alloy by in vivo and in vitro test
    Lee, MH
    Yoon, DJ
    Won, DH
    Bae, TS
    Watari, F
    METALS AND MATERIALS INTERNATIONAL, 2003, 9 (01): : 35 - 42
  • [8] Improvement in corrosion resistance of commercial pure titanium for the enhancement of its biocompatibility
    Mohsen, Q.
    Fadl-Allah, S. A.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2011, 62 (04): : 310 - 319
  • [9] Biocompatibility Research of Medicine Titanium Alloy Coating by Microarc Oxidation
    Wang, Fengbiao
    Di, Shichun
    Yu, Jie
    MANUFACTURING PROCESS TECHNOLOGY, PTS 1-5, 2011, 189-193 : 222 - +
  • [10] ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY OF COMPLEX TITANIUM NITRIDE COATING WITH THIN SURFACE OXIDE FILM DEPOSITED ON PURE TITANIUM
    Nikolova, Maria P.
    Valkov, Stefan
    Iosub, Rodica
    Yankov, Emil
    Petrov, Peter
    REVISTA ROMANA DE MATERIALE-ROMANIAN JOURNAL OF MATERIALS, 2019, 49 (01): : 42 - 50