Optimizing Viscous Damper Placement for Stochastic Performance of Buildings with Plan Asymmetry

被引:3
|
作者
Chan, Peng-Tai [1 ]
Ma, Quincy Tsun Ming [2 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Marine Environm & Engn, 70,Lienhai Rd, Kaohsiung 804, Taiwan
[2] Univ Auckland, Dept Civil & Environm Engn, 314-390 Khyber Pass Rd, Auckland 1023, New Zealand
关键词
Damper placement optimization; viscous dampers; transfer function; buildings with the asymmetric plan; moment-resisting frame; FRAMED STRUCTURES;
D O I
10.1142/S0219455425501378
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Optimized viscous dampers mitigate the dynamic response of building with plan asymmetry. Previous research efforts limit the optimization method to time domain requiring time history analyses to optimize damper placement for plan eccentricity-induced torsional response combined with translational response. This can consume high computational effort and lead to the variability in the ground motion selection. To expedite the optimization process while taking ground motion variability into account, this study will offer a novel criterion based on stochastic performance. This technique will skip the traditional approach of employing time history analyses and will take frequency domain variability into account. Through given distance between the center of mass (CM) and the target frame, the study establishes the stochastic criterion for the response at the perimeter of the building where the maximum torsional-translational response occurs. This allows the optimization methods to generate high quality solution with less computational efforts compared to traditional approach (i.e. time domain-based optimization). It is noteworthy that the proposed criterion is applicable to extensive kinds of responses (e.g. peak floor acceleration, story shear and etc.) once the geometric relationship is given. The proposed criterion as the objective function is compared against their counterpart in time domain through a case study. The case study is based on a reinforced concrete (RC) moment-resisting-frame (MRF) building with two-way asymmetric plan and adopts Element Exchange Method (EEM) to optimize the damper placement. The effectiveness of optimized design based in frequency domain and time domain is evaluated for their total running time and maximum peak interstory drift against a suite of ground motions. The result showed that the proposed criterion can offer the improvement against the traditional approach in terms of solution quality (i.e. performance in time domain and frequency domain) and computational efforts (i.e. total running time for optimization).
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Seismic performance evaluation of a spring viscous damper cable system
    Naeem, Asad
    Kim, Jinkoo
    ENGINEERING STRUCTURES, 2018, 176 : 455 - 467
  • [32] A new reduced model of damped moment frame for rapid optimization of viscous damper placement
    Akehashi, Hiroki
    Takewaki, Izuru
    JAPAN ARCHITECTURAL REVIEW, 2022, 5 (04) : 432 - 444
  • [33] Effect of viscous heating in fluid damper on the vibration isolation performance
    He, L.
    Zheng, G. T.
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2007, 21 (08) : 3060 - 3071
  • [34] A New Approach to the Optimal Placement of the Viscous Damper Based on the Static Force Distribution Pattern
    Hashemi, Mohammad Reza
    Vahdani, Reza
    Gerami, Mohsen
    Kheyroddin, Ali
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2022, 66 (03): : 866 - 875
  • [35] PERFORMANCE OF A VISCOUS-FRICTION TORSIONAL-VIBRATION DAMPER
    PERVYSHI.VG
    NAUMOV, PI
    RUSSIAN ENGINEERING JOURNAL-USSR, 1970, 50 (11): : 19 - &
  • [36] Performance and application of novel self-centering viscous damper
    Bu Z.-Y.
    He J.
    Yu B.-W.
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2023, 53 (11): : 3141 - 3150
  • [37] Optimal design and assessment of tuned mass damper inerter with nonlinear viscous damper in seismically excited multi-storey buildings
    Komal Rajana
    Zixiao Wang
    Agathoklis Giaralis
    Bulletin of Earthquake Engineering, 2023, 21 : 1509 - 1539
  • [38] Performance enhancement of FPS-isolated buildings using an inerter-based damper: Stochastic seismic analysis and optimization
    Wang, Heng
    Shen, Wenai
    Zhu, Hongping
    Wei, Wei
    Kong, Fan
    Zhu, Songye
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2022, 177
  • [39] Optimal design and assessment of tuned mass damper inerter with nonlinear viscous damper in seismically excited multi-storey buildings
    Rajana, Komal
    Wang, Zixiao
    Giaralis, Agathoklis
    BULLETIN OF EARTHQUAKE ENGINEERING, 2023, 21 (03) : 1509 - 1539
  • [40] Application of torsional tuned liquid column gas damper for plan-asymmetric buildings
    Fu, Chuan
    STRUCTURAL CONTROL & HEALTH MONITORING, 2011, 18 (05): : 492 - 509