Simultaneous electrochemical detection of ascorbic acid, dopamine and uric acid using Au decorated carbon nanofibers modified screen printed electrode

被引:4
|
作者
Sakthivel, P. [1 ]
Ramachandran, K. [1 ]
Maheshvaran, K. [2 ]
Senthil, T. S. [3 ]
Manivel, P. [3 ]
机构
[1] Builders Engn Coll, Dept Chem, Tirupur 638108, Tamil Nadu, India
[2] Kongu Engn Coll, Dept Phys, Erode 638060, Tamil Nadu, India
[3] Erode Sengunthar Engn Coll, Ctr Nanotechnol, Erode 638057, Tamil Nadu, India
关键词
Gold nanoparticles; Carbon nanofibers; Screen printed electrode; Ascorbic acid; Dopamine; Uric acid; SIMULTANEOUS VOLTAMMETRIC DETERMINATION; SELECTIVE DETECTION; NANOPARTICLES; ACETAMINOPHEN; NANOCOMPOSITE; FABRICATION; NANOSHEETS; BIOSENSOR; PLATFORM;
D O I
10.1007/s42823-024-00759-5
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Gold nanoparticles (Au NPs) decorated carbon nanofibers (CNFs) have been prepared by an electrospinning approach and then carbonized. The prepared Au-CNFs were employed to modifying a screen printed electrode (SPE) for simultaneous determination of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Au NPs are uniformly dispersed on carbon nanofibers were confirmed by the structure and morphological studies. The modified electrodes were tested in cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CA) to characterize their electrochemical responses. Compared to bare SPE, the Au-CNFs/SPE had a better sensing response to AA, DA, and UA. The electrochemical oxidation signal of AA, DA and UA are well separated into three distinct peaks with peak potential separation of 280 mV, 159 mV and 439 mV between AA-DA, DA-UA and AA-UA respectively in CV studies and the corresponding peak potential separation in DPV studies are 290 mV, 166 mV and 456 mV. The Au-CNFs/SPE has a wide linear response of AA, DA and UA in DPV analysis over the range of 5-40 mu M (R2 = 0.9984), 2-16 mu M (R2 = 0.9962) and 2-16 mu M (R2 = 0.9983) with corresponding detection limits of 0.9 mu M, 0.4 mu M and 0.3 mu M at S/N = 3, respectively. The developed modified SPE based sensor exhibits excellent reproducibility, stability, and repeatability. The excellent sensing response of Au-CNFs could reveal to a promising approach in electrochemical sensor.
引用
收藏
页码:2325 / 2341
页数:17
相关论文
共 50 条
  • [21] Simultaneous electrochemical determination of uric acid, dopamine, and ascorbic acid at single-walled carbon nanohorn modified glassy carbon electrode
    Zhu, Shuyun
    Li, Haijuan
    Niu, Wenxin
    Xu, Guobao
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (04): : 940 - 943
  • [22] Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Nitrogen Doped Carbon Sphere Modified Glassy Carbon Electrode
    Ye, Fucheng
    Wen, Zubiao
    Wu, Hongfu
    Wang, Chunyan
    Qian, Yong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1136 - 1143
  • [23] Simultaneous electrochemical detection of uric acid and ascorbic acid at a silver doped poly(glutamic acid) modified glassy carbon electrode
    Sun, D. M.
    Hu, W. N.
    Ma, W.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (03) : 310 - 316
  • [24] Simultaneous electrochemical detection of uric acid and ascorbic acid at a silver doped poly(glutamic acid) modified glassy carbon electrode
    D. M. Sun
    W. N. Hu
    W. Ma
    Journal of Analytical Chemistry, 2011, 66 : 310 - 316
  • [25] Simultaneous determination of dopamine, ascorbic acid, and uric acid using carbon ionic liquid electrode
    Safavi, Afsaneh
    Maleki, Norouz
    Moradlou, Omran
    Tajabadi, Fariba
    ANALYTICAL BIOCHEMISTRY, 2006, 359 (02) : 224 - 229
  • [26] Poly(thionine)-modified GC Electrode for Simultaneous Detection of Dopamine and Uric Acid in the Presence of Ascorbic Acid
    Yuan, Yong
    Ahammad, A. J. Saleh
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2008, 29 (10) : 1883 - 1884
  • [27] Poly(thionine)-modified GC electrode for simultaneous detection of dopamine and uric acid in the presence of ascorbic acid
    Yuan, Yong
    Ahammad, A. J. Saleh
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    1883, Korean Chemical Society, Seoul, 135-703, South Korea (29)
  • [28] Simultaneous Detection of Ascorbic Acid, Dopamine, Uric Acid and Tryptophan on the PEI-graphene Modified Electrode
    Li Chong
    Jia Liping
    Ma Rongna
    Jia Wenli
    Wang Huaisheng
    Yang Haitao
    Guo Aixiang
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2015, 36 (07): : 1282 - 1290
  • [29] Simultaneous determination of dopamine, uric acid and ascorbic acid using a glassy carbon electrode modified with reduced graphene oxide
    Wang, Huiwen
    Ren, Fangfang
    Wang, Caiqin
    Yang, Beibei
    Bin, Duan
    Zhang, Ke
    Du, Yukou
    RSC ADVANCES, 2014, 4 (51) : 26895 - 26901
  • [30] Electrodeposition of platinum nanosheets on C60 decorated glassy carbon electrode as a stable electrochemical biosensor for simultaneous detection of ascorbic acid, dopamine and uric acid
    Zhang, Xuan
    Ma, Li-Xia
    Zhang, Yi-Chi
    ELECTROCHIMICA ACTA, 2015, 177 : 118 - 127