Marginal bone loss in ball versus locator attachments in implant-retained overdentures: systematic review and meta-analysis

被引:0
|
作者
Mahmoud, Mohamed R. [1 ]
Rashwan, Noha [1 ]
Marzouk, Tamer [2 ]
Porcello, Lorraine [3 ]
Becker, Rachel W. [4 ]
Barmak, Abdul Basir [5 ]
Malmstrom, Hans [1 ]
机构
[1] Univ Rochester, Gen Dent Dept, Eastman Inst Oral Hlth, 625 Elmwood Ave, Rochester, NY 14621 USA
[2] Univ Rochester, Eastman Inst Oral Hlth, Rochester, NY USA
[3] Univ Rochester, Rochester, NY USA
[4] Univ Rochester, Eastman Inst Oral Hlth, Rochester, NY USA
[5] Univ Rochester, Eastman Inst Oral Hlth, Clin Res & Biostat, New York, NY USA
来源
QUINTESSENCE INTERNATIONAL | 2024年 / 55卷 / 06期
关键词
ball attachment; dental implantation; dental prosthesis; denture attachment; edentulous; implant-supported; loca- tor attachment; marginal bone loss; overlay; prosthesis retention; SUPPORTED MANDIBULAR OVERDENTURES; DIFFERENT LOADING PROTOCOLS; FOLLOW-UP; IN-VITRO; SUCCESS; CRITERIA; FAILURE; MAGNET;
D O I
10.3290/j.qi.b5213685
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This systematic review compares the impact of ball and locator attachments on marginal bone loss in implant -retained overdentures in completely edentulous patients. Method and materials: Following PRISMA guidelines, health science librarians completed literature searches from inception to 17 March 2023 in seven databases. There were 15,686 items exported to End Note from Embase.com, CINAHL (EBSCO), Cochrane Library, Ovid MEDLINE-ALL, PubMed, Scopus, and Web of Science. Hand -searching added four more articles. After deduplication, 6,756 items were screened for eligibility. Twenty-nine studies were assessed by full text, of which ten studies, involving 424 subjects, were included in the review. Risk of bias assessment was conducted using the Cochrane risk -of -bias tool and the Newcastle -Ottawa scale. A meta -analysis was performed to synthesize and analyze the collective data from the selected studies. Results: The included studies used diverse methodologies, implant systems, and loading protocols. Most studies reported no significant difference in marginal bone loss between ball and locator attachments. The meta -analysis revealed high heterogeneity. Conclusion: The results of this systematic review suggest that ball and locator attachments exhibit similar performance in terms of marginal bone loss in implant -retained overdentures. However, the limited number, risk of bias, and heterogeneity of studies high light the need for standardized research designs and larger sample sizes in future investigations to draw more definitive conclusions. (Quintessence Int2024;55:442-458; d o i:10.3290/j. q i. b5213685)
引用
收藏
页码:442 / 458
页数:17
相关论文
共 50 条
  • [31] Mini-Implant-Retained Overdentures for the Rehabilitation of Completely Edentulous Maxillae: A Systematic Review and Meta-Analysis
    Vi, Serena
    Pham, Damon
    Du, Yu Yian Marina
    Arora, Himanshu
    Tadakamadla, Santosh Kumar
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (08)
  • [32] Influence of abutment height on peri-implant marginal bone loss: A systematic review and meta-analysis
    Chen, Zhaozhao
    Lin, Cho-Ying
    Li, Junying
    Wang, Hom-Lay
    Yu, Haiyang
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (01): : 14 - +
  • [33] Does the implant-abutment interface interfere on marginal bone loss? A systematic review and meta-analysis
    Rosa, Eneias Carpejani
    Deliberador, Tatiana Miranda
    de Lima do Nascimento, Tuanny Carvalho
    de Almeida Kintopp, Cibele Candida
    Rocha Orsi, Juliana Shaia
    Wambier, Leticia Maira
    Khajotia, Sharukh Soli
    Esteban Florez, Fernando Luis
    Mueller Storrer, Carmen Lucia
    BRAZILIAN ORAL RESEARCH, 2019, 33
  • [34] Risk of Implant Failure and Marginal Bone Loss in Subjects with a History of Periodontitis: A Systematic Review and Meta-Analysis
    Safii, Syarida H.
    Palmer, Richard M.
    Wilson, Ron F.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2010, 12 (03) : 165 - 174
  • [35] Effect of Platelet Concentrates on Marginal Bone Loss of Immediate Implant Procedures: A Systematic Review and Meta-Analysis
    Gonzalez-Serrano, Jose
    Vallina, Carmen
    Gonzalez-Serrano, Carlos
    Sanchez-Monescillo, Andres
    Torres, Jesus
    Hernandez, Gonzalo
    Maria Lopez-Pintor, Rosa
    MATERIALS, 2021, 14 (16)
  • [37] Assessment of the Effect of Clinical Independent Risk Factors on Marginal Bone Loss in 2-Implant-Supported Locator-Retained Mandibular Overdentures
    Mumcu, Emre
    Dereci, Omur
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (03) : 207 - 212
  • [38] Evaluation of volumetric wear of abutments on the retention loss of ball attachment systems in implant-retained overdentures: An in vitro study
    Yabul, Ali
    Dayan, Cagatay
    Geckili, Onur
    Bilhan, Hakan
    Tuncer, Necat
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (05) : 778 - 784
  • [39] A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: Three-year results
    MacEntee, MI
    Walton, JN
    Glick, N
    JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (01): : 28 - 37
  • [40] Clinical and radiographic outcomes of mini-implant-retained maxillary and mandibular overdentures: a systematic review and meta-analysis
    Mohammadi, Morteza
    Baker, Emad
    Chrcanovic, Bruno Ramos
    CLINICAL ORAL INVESTIGATIONS, 2025, 29 (03)