A two-stage deep-learning framework for CT denoising based on a clinically structure-unaligned paired data set

被引:2
|
作者
Hu, Ruibao [1 ,2 ]
Luo, Honghong [3 ,4 ]
Zhang, Lulu [1 ]
Liu, Lijian [3 ,4 ]
Liu, Honghong [3 ,4 ]
Wu, Ruodai [5 ]
Luo, Dehong [3 ,4 ]
Liu, Zhou [3 ,4 ]
Hu, Zhanli [1 ]
机构
[1] Chinese Acad Sci, Lauterbur Res Ctr Biomed Imaging, Shenzhen Inst Adv Technol, 1068 Xueyuan Ave,Shenzhen Univ Town, Shenzhen 518055, Peoples R China
[2] Anhui Normal Univ, Sch Comp & Informat, Wuhu, Peoples R China
[3] Chinese Acad Med Sci & Peking Union Med Coll, Dept Radiol, Natl Canc Ctr, Natl Clin Res Ctr Canc,Canc Hosp, 113 Baohe Ave, Shenzhen 518116, Peoples R China
[4] Chinese Acad Med Sci & Peking Union Med Coll, Shenzhen Hosp, 113 Baohe Ave, Shenzhen 518116, Peoples R China
[5] Shenzhen Univ, Shenzhen Univ Gen Hosp, Clin Med Acad, Dept Radiol, Shenzhen, Peoples R China
基金
中国国家自然科学基金;
关键词
Computed tomography (CT); structure-unaligned image; Wasserstein generative adversarial network (WGAN); attention mechanism; LOW-DOSE CT; GENERATIVE ADVERSARIAL NETWORK; IMAGE-RECONSTRUCTION; NOISE-REDUCTION; CANCER; MORTALITY;
D O I
10.21037/qims-23-403
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In low-dose computed tomography (LDCT) lung cancer screening, soft tissue is hardly appreciable due to high noise levels. While deep learning-based LDCT denoising methods have shown promise, they typically rely on structurally aligned synthesized paired data, which lack consideration of the clinical reality that there are no aligned LDCT and normal-dose CT (NDCT) images available. This study introduces an LDCT denoising method using clinically structure-unaligned but paired data sets (LDCT and NDCT scans from the same patients) to improve lesion detection during LDCT lung cancer screening. Methods: A cohort of 64 patients undergoing both LDCT and NDCT was randomly divided into training (n=46) and testing (n=18) sets. A two-stage training approach was adopted. First, Gaussian noise was added to NDCT data to create simulated LDCT data for generator training. Then, the model was trained on a clinically structure-unaligned paired data set using a Wasserstein generative adversarial network (WGAN) framework with the initial generator weights obtained during the first stage of training. An attention mechanism was also incorporated into the network. Results: Validated on a clinical CT data set, our proposed method outperformed other available methods [CycleGAN, Pixel2Pixel, block-matching and three-dimensional filtering (BM3D)] in noise removal and detail retention tasks in terms of the peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), and root mean square error (RMSE) metrics. Compared with the results produced by BM3D, our method yielded an average improvement of approximately 7% in terms of the three evaluation indicators. The probability density profile of the denoised CT output produced using our method best fit the reference NDCT scan. Additionally, our two-stage model outperformed the one-stage WGAN-based model in both objective and subjective evaluations, further demonstrating the higher effectiveness of our two-stage training approach. Conclusions: The proposed method performed the best in removing noise from LDCT scans and exhibited good detail retention, which could potentially enhance the lesion detection and characterization effects obtained for soft tissues in the scanning scope of LDCT lung cancer screening.
引用
收藏
页码:335 / 351
页数:18
相关论文
共 50 条
  • [41] A two-stage network framework for topology optimization incorporating deep learning and physical information
    Wang, Dalei
    Ning, Yun
    Xiang, Cheng
    Chen, Airong
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2024, 133
  • [42] A two-stage deep learning framework for counterfeit luxury handbag detection in logo images
    Jianbiao Peng
    Beiji Zou
    Chengzhang Zhu
    Signal, Image and Video Processing, 2023, 17 : 1439 - 1448
  • [43] A Novel Two-Stage Deep Learning Structure for Network Flow Anomaly Detection
    Kao, Ming-Tsung
    Sung, Dian-Ye
    Kao, Shang-Juh
    Chang, Fu-Min
    ELECTRONICS, 2022, 11 (10)
  • [44] TSDLPP: A Novel Two-Stage Deep Learning Framework For Prognosis Prediction Based on Whole Slide Histopathological Images
    Liu, Yu
    Li, Ao
    Liu, Jiangshu
    Meng, Gang
    Wang, Minghui
    IEEE-ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2022, 19 (04) : 2523 - 2532
  • [45] A two-stage deep-learning model for determination of the contact of mandibular third molars with the mandibular canal on panoramic radiographs
    Soltani, Parisa
    Sohrabniya, Fatemeh
    Mohammad-Rahimi, Hossein
    Mehdizadeh, Mojdeh
    Mousavi, Seyed Mohammadreza
    Moaddabi, Amirhossein
    Mousavi, Seyed Mohammadmahdi
    Spagnuolo, Gianrico
    Yavari, Amirmohammad
    Schwendicke, Falk
    BMC ORAL HEALTH, 2024, 24 (01):
  • [46] MARNet: An Efficient Two-Stage Intrusion Detection Model Based on Deep Learning
    Wu, Jiang
    Fu, Qiang
    Wang, Liang
    IEEE ACCESS, 2025, 13 : 2377 - 2388
  • [47] Fabric Defect Detection Algorithm Based on Two-stage Deep Transfer Learning
    Zhao S.
    Zhang J.
    Wang J.
    Xu C.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2021, 57 (17): : 86 - 97
  • [48] Two-Stage Unsupervised Hyperspectral Band Selection Based on Deep Reinforcement Learning
    Guo, Yi
    Wang, Qianqian
    Hu, Bingliang
    Qian, Xueming
    Ye, Haibo
    REMOTE SENSING, 2025, 17 (04)
  • [49] A two-stage deep learning-based system for patent citation recommendation
    Jaewoong Choi
    Jiho Lee
    Janghyeok Yoon
    Sion Jang
    Jaeyoung Kim
    Sungchul Choi
    Scientometrics, 2022, 127 : 6615 - 6636
  • [50] A two-stage deep-learning-based balancing method for rotating machinery
    Zhong, Shun
    Han, Hong-Xiang
    Hou, Lei
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (04)