Pilot scale removal of organic micropollutants by combining ozonation with powdered activated carbon
被引:1
|
作者:
Lind, Petter
论文数: 0引用数: 0
h-index: 0
机构:
Envidan AB, Hans Michelsensgatan 2A, S-21120 Malmo, SwedenEnvidan AB, Hans Michelsensgatan 2A, S-21120 Malmo, Sweden
Lind, Petter
[1
]
Sauvignet, Philippe
论文数: 0引用数: 0
h-index: 0
机构:
Veolia, 30 Rue Madeleine Vionnet, Aubervilliers F- 933000, FranceEnvidan AB, Hans Michelsensgatan 2A, S-21120 Malmo, Sweden
Sauvignet, Philippe
[2
]
Flodin, Jonatan
论文数: 0引用数: 0
h-index: 0
机构:
Storgatan 37, S-43481 Kungsbacka, SwedenEnvidan AB, Hans Michelsensgatan 2A, S-21120 Malmo, Sweden
Flodin, Jonatan
[3
]
Bourghardt, Charlotte
论文数: 0引用数: 0
h-index: 0
机构:
Storgatan 37, S-43481 Kungsbacka, SwedenEnvidan AB, Hans Michelsensgatan 2A, S-21120 Malmo, Sweden
Bourghardt, Charlotte
[3
]
Bengtsson, Simon
论文数: 0引用数: 0
h-index: 0
机构:
VA SYD, Box 191, S-20121 Malmo, Sweden
Sweden Water Res, Scheelevagen 15, S-22370 Lund, SwedenEnvidan AB, Hans Michelsensgatan 2A, S-21120 Malmo, Sweden
Bengtsson, Simon
[4
,5
]
机构:
[1] Envidan AB, Hans Michelsensgatan 2A, S-21120 Malmo, Sweden
[2] Veolia, 30 Rue Madeleine Vionnet, Aubervilliers F- 933000, France
[3] Storgatan 37, S-43481 Kungsbacka, Sweden
[4] VA SYD, Box 191, S-20121 Malmo, Sweden
[5] Sweden Water Res, Scheelevagen 15, S-22370 Lund, Sweden
Pilot experiments were conducted to assess the removal of organic micropollutants from biologically treated wastewater at a municipal wastewater treatment plant in Sweden. Powdered activated carbon (PAC) was combined with a low dose of ozone and added directly before the PAC contact tank, enabling ozone to react simultaneously with the PAC and the wastewater contaminants. This combination of ozone and PAC was compared to PAC or ozone alone. The process, which included coagulation/flocculation and ballasted high-rate lamella sedimentation, proved to be both robust and efficient for the removal of micropollutants. The addition of 1.3 mg PAC/mg DOC resulted in a 73% average reduction of micropollutants. With the addition of 0.13 mg O-3/mg DOC, the reduction increased to 83%, which was similar to the outcome with the addition of 30 mg/L PAC without ozone. The process configuration and operating conditions did not lead to any detectable bromate formation despite relatively high influent bromide levels. The estimated operating costs for combining PAC with a low dose of ozone were significantly lower than for applying a higher PAC dose. Thus, this way of combining PAC with ozone seems to have several advantages with respect to treatment efficiency and operation.
机构:
Ewha Womans Univ, Dept Environm Sci & Engn, Seoul 120750, South KoreaEwha Womans Univ, Dept Environm Sci & Engn, Seoul 120750, South Korea
Kim, Eunseon
Jung, Chanil
论文数: 0引用数: 0
h-index: 0
机构:
Montclair State Univ, Dept Earth & Environm Studies, Montclair, NJ 07043 USAEwha Womans Univ, Dept Environm Sci & Engn, Seoul 120750, South Korea
Jung, Chanil
Han, Jonghun
论文数: 0引用数: 0
h-index: 0
机构:
Korea Army Acad Young Cheon, Dept Civil & Environm Engn, Young Cheon 770849, Gyeongbuk, South KoreaEwha Womans Univ, Dept Environm Sci & Engn, Seoul 120750, South Korea
Han, Jonghun
Her, Namguk
论文数: 0引用数: 0
h-index: 0
机构:
Korea Army Acad Young Cheon, Dept Civil & Environm Engn, Young Cheon 770849, Gyeongbuk, South KoreaEwha Womans Univ, Dept Environm Sci & Engn, Seoul 120750, South Korea
Her, Namguk
Park, Chang Min
论文数: 0引用数: 0
h-index: 0
机构:
Univ South Carolina, Dept Civil & Environm Engn, Columbia, SC 29208 USAEwha Womans Univ, Dept Environm Sci & Engn, Seoul 120750, South Korea
机构:
Univ Duisburg Essen, Fac Engn Sci, Inst Energy & Environm Engn Water Technol, D-47057 Duisburg, GermanyUniv Novi Sad, Fac Sci, Novi Sad 21000, Serbia