Development of a highly sensitive method based on QuEChERS and GC-MS/MS for the determination of polycyclic aromatic hydrocarbons in infant foods

被引:1
|
作者
Ingegno, Mariateresa [1 ]
Zianni, Rosalia [1 ]
Della Rovere, Ines [1 ]
Chiappinelli, Andrea [1 ]
Nardelli, Valeria [1 ]
Casamassima, Francesco [1 ]
Calitri, Anna [1 ]
Quinto, Maurizio [2 ]
Nardiello, Donatella [2 ]
Iammarino, Marco [1 ]
机构
[1] Ist Zooprofilatt Sperimentale Puglia & Basilicata, Struttura Complessa Chim, Foggia, Italy
[2] Univ Foggia, Dept Agr Food Nat Resources & Engn DAFNE, Foggia, Italy
来源
FRONTIERS IN NUTRITION | 2024年 / 11卷
关键词
food safety; GC-MS/MS; infant foods; polycyclic aromatic hydrocarbons (PAHs); QuEChERS; validation; PESTICIDE-RESIDUES; PAHS; EXTRACTION; MUTAGENICITY; LEGISLATION; RISK;
D O I
10.3389/fnut.2024.1403541
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Polycyclic aromatic hydrocarbons (PAHs) are environmental contaminants that can be found in various food products, including those intended for infants. Due to their potential health risks, it is crucial to develop sensitive analytical methods for the accurate determination of PAHs in infant foods. This study describes the development and validation of a highly sensitive method for the quantification of European PAH markers, namely benzo[a]pyrene, benzo[a]anthracene, chrysene, and benzo[b]fluoranthene, using gas chromatography-tandem mass spectrometry (GC-MS/MS), in baby food samples. The first step was the optimization of the sample preparation procedure, performed using different methods based on the QuEChERS approach, also testing different extraction solvents. Several factors such as extraction efficiency, selectivity, and recovery were evaluated to choose the most effective procedure for sample preparation. Furthermore, the GC-MS/MS method was optimized, evaluating parameters such as linearity, sensitivity, accuracy, and robustness using spiked infant food samples. The method demonstrated excellent linearities with a correlation coefficient higher than 0.999 over a wide concentration range, and limits of detection and limits of quantification in the range 0.019-0.036 mu g/kg and 0.06-0.11 mu g/kg, respectively. Extraction recoveries were between 73.1 and 110.7%, with relative standard deviations always lower than 8%. These findings are compliant with the indications of the European Commission (Reg. 836/2011). To assess the applicability of the method to official control activities, a survey was conducted on commercially available infant food products. Four markers were determined in commercial samples belonging to different food categories for infants and young children. The outcome of this monitoring showed that PAH contamination, in all samples, was below the quantification limits. In conclusion, the developed GC-MS/MS method provides a highly sensitive and reliable approach for the determination of PAHs in baby foods. The optimized sample preparation, instrumental parameters, and validation results ensure accurate quantification of 4 PAHs even at trace levels. This method could contribute to the assessment of PAH exposure in infants and it could support regulatory efforts to ensure the safety and quality of infant food products with regular monitoring.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Determination of n-alkanes, polycyclic aromatic hydrocarbons and hopanes in atmospheric aerosol: evaluation and comparison of thermal desorption GC-MS and solvent extraction GC-MS approaches
    Wang, Meng
    Huang, Ru-Jin
    Cao, Junji
    Dai, Wenting
    Zhou, Jiamao
    Lin, Chunshui
    Ni, Haiyan
    Duan, Jing
    Wang, Ting
    Chen, Yang
    Li, Yongjie
    Chen, Qi
    El Haddad, Imad
    Hoffmann, Thorsten
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (09) : 4779 - 4789
  • [42] Study on four metal organic frameworks as cleanup adsorbents for polycyclic aromatic hydrocarbons determined by GC-MS/MS
    Yu-Han Fan
    Xiao-Xuan Mou
    Shi-Bin Qin
    Xiao-Shui Li
    Shi-Hua Qi
    Microchimica Acta, 2019, 186
  • [43] Study on four metal organic frameworks as cleanup adsorbents for polycyclic aromatic hydrocarbons determined by GC-MS/MS
    Fan, Yu-Han
    Mou, Xiao-Xuan
    Qin, Shi-Bin
    Li, Xiao-Shui
    Qi, Shi-Hua
    MICROCHIMICA ACTA, 2019, 186 (03)
  • [44] Monofluorinated analogues of polycyclic aromatic hydrocarbons as internal standards for GC-MS in environmental analysis
    G. Luthe
    L. Ramos
    J. Dallüge
    U. A. Th. Brinkman
    Chromatographia, 2003, 57 : 379 - 383
  • [45] ANALYSIS OF POLYCYCLIC AROMATIC-HYDROCARBONS IN URBAN RUNOFF BY FLUORESCENCE SPECTROMETRY AND GC-MS
    NGABE, B
    SCOTT, GI
    BIDLEMAN, TF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 17 - GEOC
  • [46] GC-MS analysis of polycyclic aromatic hydrocarbons in bottled olive oil marketed in Lebanon
    Elaridi, Jomana
    Fakhro, Maysa
    Yamani, Osama
    Dimassi, Hani
    Othman, Hiba
    Attieh, Zouhair
    TOXICOLOGICAL RESEARCH, 2020, 36 (03) : 211 - 220
  • [47] Monofluorinated analogues of polycyclic aromatic hydrocarbons as internal standards for GC-MS in environmental analysis
    Luthe, G
    Ramos, L
    Dallüge, J
    Brinkman, UAT
    CHROMATOGRAPHIA, 2003, 57 (5-6) : 379 - 383
  • [48] Simultaneous determination of PAHs and pesticides in milk based on improved QuEChERS combined with GC-MS/MS
    Qin, Jingyin
    Tong, Kaixuan
    Chang, Qiaoying
    Xie, Yujie
    Wu, Xingqiang
    Fan, Chunlin
    Zhang, Hongyi
    Shi, Zhihong
    Chen, Hui
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2025, 141
  • [49] Development and validation of GC/MS method for simultaneous determination of 16 polycyclic aromatic hydrocarbons (PAHs) in pork meat matrix
    Givechev, Ivan
    Tanev, Dimitar
    Danalev, Dancho
    ACTA CHROMATOGRAPHICA, 2021, 33 (01) : 57 - 63
  • [50] Quantitative determination of polychlorinated biphenyls in chicken based on QuEChERS extraction and GC-MS/MS detection
    Zhang, Yuan
    Zhao, Jianwei
    Jin, Zhengyu
    Gao, Yahui
    Chen, Long
    FOOD CONTROL, 2023, 147