Simultaneous extraction of polycyclic aromatic hydrocarbons and tetracycline antibiotics from honey samples using dispersive solid phase extraction combined with dispersive liquid-liquid microextraction before their determination with HPLC-DAD

被引:1
|
作者
Khatami, Arman [1 ]
Moghaddam, Arasb Dabbagh [1 ,2 ]
Talatappeh, Hossein Dini [2 ]
Mohammadimehr, Mojgan [3 ]
机构
[1] Aja Univ Med Sci, Infect Dis Res Ctr, Tehran, Iran
[2] Aja Univ Med Sci, Fac Med, Dept Publ Hlth & Nutr, Tehran, Iran
[3] Aja Univ Med Sci, Fac Paramed, Infect Dis Res Ctr, Dept Lab Sci, Tehran, Iran
关键词
Dispersive solid phase extraction; Magnetic deep eutectic solvent; High-performance liquid chromatography; Polycyclic aromatic hydrocarbons; Honey; HEALTH; RESIDUES; ESTERS; PAHS;
D O I
10.1016/j.jfca.2024.106179
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A dispersive solid-phase extraction method combined with dispersive liquid-liquid microextraction was offered for the extraction of four polycyclic aromatic hydrocarbons (anthracene, fluorene, phenanthrene, and pyrene) and tetracycline antibiotics (tetracycline, oxytetracycline, and chlortetracycline) from honey samples, simultaneously. In this work, cobalt-gallic acid bio-metal organic framework was synthesized and 20 mg of it was added into of 10 mL the diluted honey solution to efficiently adsorb the analytes. After vortexing (3 min) and centrifuging, the sorbent particles were eluted with 0.75 mL acetonitrile under vortexing for 3 min. In the following, this phase was mixed with 55 mu L [Ch: 4-chlorophenol] + [FeCl 4 ] - magnetic deep eutectic solvent and rapidly injected into deionized water. After separating the extractant phase in the presence of an external magnet and diluting it with the mobile phase, it was injected into a high -performance liquid chromatography-diode array detector. Under optimum extraction conditions, extraction recoveries were in the range of 63 -84%. The limits of detection of the opted polycyclic aromatic hydrocarbons and tetracyclines were in the ranges of 0.18 -0.26 and 0.25 -0.29 ng g -1 , respectively. Also, good repeatability (relative standard deviations <= 7.5 and 8.3% for intra - (n=6) and inter -day (n=4) precisions, respectively) was obtained. In summary, the validated method was successfully recommended for the determination of polycyclic aromatic hydrocarbons and tetracyclines in various honey samples and pyrene was found in two samples at 5.5 and 12.9 ng g -1 . The used bio-metal organic framework has sufficient ability in extraction of different classes of compounds (polycyclic aromatic hydrocarbons and antibiotics) from honey. Performing the microextraction step has direct effect in analysis of the analytes in low concentrations and the use of magnetic solvents, eliminate the use of centrifugation in this step.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A three phase dispersive liquid-liquid microextraction technique for the extraction of antibiotics in milk
    Adlnasab, Laleh
    Ebrahimzadeh, Homeira
    Yamini, Yadollah
    MICROCHIMICA ACTA, 2012, 179 (1-2) : 179 - 184
  • [32] Dispersive liquid-liquid microextraction of parabens from pharmaceuticals and personal care products prior to their determination using HPLC-DAD
    Hassan, Malek
    Alshana, Usama
    Ertas, Nusret
    TURKISH JOURNAL OF CHEMISTRY, 2019, 43 (06) : 1634 - 1645
  • [33] Simultaneous Determination of Permethrin and Deltamethrin in Water Samples by Magnetic Solid-phase Extraction coupled with Dispersive Liquid-Liquid Microextraction combined with Gas Chromatography
    Noori, Arezoo Hassan
    Rezaee, Mohammad
    Kazemipour, Maryam
    Mashayekhi, Hossein Ali
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 2017, 70 : 200 - 208
  • [34] Combination of dispersive solid phase extraction and dispersive liquid-liquid microextraction for extraction of some aryloxy pesticides prior to their determination by gas chromatography
    Farajzadeh, Mir Ali
    Yadeghari, Adeleh
    Khoshmaram, Leila
    MICROCHEMICAL JOURNAL, 2017, 131 : 182 - 191
  • [35] Determination of sulfonamide residues in animal foodstuffs by magnetic dispersive solid-phase extraction using magnetic carbon nanocomposites coupled with ion pair-dispersive liquid-liquid micro-extraction combined with HPLC-DAD
    Yazdanfar, Najmeh
    Shamsipur, Mojtaba
    Ghambarian, Mahnaz
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2021, 18 (06) : 1433 - 1442
  • [36] Determination of Triazoles in Tea Samples Using Dispersive Solid Phase Extraction Combined with Dispersive Liquid–Liquid Microextraction Followed by Liquid Chromatography–Tandem Mass Spectrometry
    Yu Zhang
    Hui Xu
    Food Analytical Methods, 2014, 7 : 189 - 196
  • [37] Dispersive solid phase extraction-dispersive liquid-liquid microextraction of mycotoxins from milk samples and investigating their decontamination using microwave irradiations
    Badali, Akbar
    Javadi, Afshin
    Mogaddam, Mohammad Reza Afshar
    Mashak, Zohreh
    MICROCHEMICAL JOURNAL, 2023, 190
  • [38] Development of a dispersive liquid-liquid microextraction coupled with magnetic dispersive microsolid phase extraction for determination of triazines in wastewater samples
    Aguilar-Arteaga, Karina
    Hernandez-Mera, Cynthia
    Diaz-Batalla, Luis
    Castaneda-Ovando, Araceli
    Cruz-Perez, Alida Elizabeth
    Barrado-Esteban, Enrique
    Carrillo-Cardenas, Manuel
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (05) : 1203 - 1213
  • [39] Enhancement of sensitivity for the spectrophotometric determination of carbaryl using dispersive liquid microextraction combined with dispersive μ-solid phase extraction
    Mukdasai, Siriboon
    Thomas, Chunpen
    Srijaranai, Supalax
    ANALYTICAL METHODS, 2013, 5 (03) : 789 - 796
  • [40] Determination of 16 Polycyclic Aromatic Hydrocarbons in Tea by Simultaneous Dispersive Solid-Phase Extraction and Liquid-Liquid Extraction Coupled with gas Chromatography-Tandem Mass Spectrometry
    Chen, Hongping
    Gao, Guanwei
    Liu, Pingxiang
    Pan, Rong
    Liu, Xin
    Lu, Chengyin
    FOOD ANALYTICAL METHODS, 2016, 9 (08) : 2374 - 2384