Experimental Research on Pressure Pulsation and Flow Structures of the Low Specific Speed Centrifugal Pump

被引:0
|
作者
Lv, Weiling [1 ]
Zhang, Yang [1 ]
Zhang, Wenbin [1 ]
Ni, Ping [1 ]
Li, Changjiang [1 ]
Chen, Jiaqing [2 ]
Gao, Bo [2 ]
机构
[1] Shanghai Marine Equipment Res Inst SMERI, Shanghai 200031, Peoples R China
[2] Jiangsu Univ, Sch Energy & Power Engn, Zhenjiang 212013, Peoples R China
关键词
low specific speed centrifugal pump; transient pressure pulsation; pressure spectrum analysis; PIV measurement; DIFFUSER; BLADE;
D O I
10.3390/en17184730
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The low specific speed centrifugal pump plays a crucial role in industrial applications, and ensuring its efficient and stable operation is extremely important for the safety of the whole system. The pump must operate with an extremely high head, an extremely low flow rate, and a very fast speed. The internal flow structure is complex and there is a strong interaction between dynamic and static components; consequently, the hydraulic excitation force produced becomes a significant factor that triggers abnormal vibrations in the pump. Therefore, this study focuses on a low specific speed centrifugal pump and uses a single-stage model pump to conduct PIV and pressure pulsation tests. The findings reveal that the PIV tests successfully captured the typical jet-wake structure at the outlet of the impeller, as well as the flow separation structure at the leading edge of the guide vanes and the suction surface. On the left side of the discharge pipe, large-scale flow separation and reverse flow happen as a result of the flow-through effect, producing a strong vortex zone. The flow field on the left side of the pressure chamber is relatively uniform, and the low-speed region on the suction surface of the guide vanes is reduced due to the reverse flow. The results of the pressure pulsation test showed that the energy of pressure pulsation in the flow passage of the guide vane occurs at the fBPF and its harmonics, and the interaction between the rotor and stator is significant. Under the same operating condition, the RMS value distribution and amplitude at fBPF of each measurement point are asymmetric in the circumferential direction. The amplitude of fBPF near the discharge pipe is lower, while the RMS value is higher. A complex flow structure is shown by the larger amplitude and RMS value of the fBPF on the left side of the pressure chamber. With the flow rate increasing, the energy at fBPF of each measurement point increases first and then decreases, while the RMS value decreases, indicating a more uniform flow field inside the pump.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Evaluation of the front leakage flow in a low-specific-speed centrifugal pump
    Pelegri, Marc
    Armengol, Jordi
    Ramon Gonzalez, Josep
    Pujol, Toni
    Montoro, Lino
    Tubert, Pere
    ENVIRONMENTAL HYDRAULICS: THEORETICAL, EXPERIMENTAL AND COMPUTATIONAL SOLUTIONS, 2010, : 273 - +
  • [32] Computational study of pressure pulsation in a medium specific speed pump
    Timouchev, Serguei
    Proceedings of the ASME Fluids Engineering Division Summer Conference - 2005, Vol 1, Pts A and B, 2005, : 1417 - 1424
  • [33] Experimental and Numerical Investigation of Pressure Fluctuation in a Low-Specific-Speed Centrifugal Pump with a Gap Drainage Impeller
    Zhang, Li
    Li, Hui
    Xu, Hong
    Shi, Weidong
    Yang, Yang
    Wang, Wanhong
    Zhou, Ling
    SHOCK AND VIBRATION, 2021, 2021
  • [34] Improve of Unsteady Pressure Pulsation Based on Jet-Wake Suppression for a Low Specific Centrifugal Pump
    Wu, Chengshuo
    Li, Qianqian
    Zheng, Feng
    Wu, Peng
    Yang, Shuai
    Ye, Haojie
    Huang, Bin
    Wu, Dazhuan
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2021, 143 (11):
  • [35] Numerical Analysis and Experimental Study of Unsteady Flow Characteristics in an Ultra-Low Specific Speed Centrifugal Pump
    Wei, Yangyang
    Shi, Yuhui
    Shi, Weidong
    Pan, Bo
    SUSTAINABILITY, 2022, 14 (24)
  • [36] Pressure pulsation of centrifugal pump with tilt volute
    School of Energy and Power Engineering, Jiangsu University, Zhenjiang 212013, China
    Jixie Gongcheng Xuebao, 14 (164-168):
  • [37] Effect of the volute tongue cut on pressure pulsations of a low specific speed centrifugal pump
    Ning Zhang
    Bo Gao
    Bin Xia
    Qi-feng Jiang
    Journal of Hydrodynamics, 2020, 32 : 758 - 770
  • [38] Effect of the volute tongue cut on pressure pulsations of a low specific speed centrifugal pump
    Zhang, Ning
    Gao, Bo
    Xia, Bin
    Jiang, Qi-feng
    JOURNAL OF HYDRODYNAMICS, 2020, 32 (04) : 758 - 770
  • [39] Effect of suction chamber baffles on pressure fluctuations in a low specific speed centrifugal pump
    Luo, Kaikai
    Wang, Yong
    Liu, Houlin
    Chen, Jie
    Li, Yu
    Yan, Jun
    JOURNAL OF VIBROENGINEERING, 2019, 21 (05) : 1441 - 1455
  • [40] Experimental Investigation on Unsteady Pressure Pulsation in a Centrifugal Pump With Special Slope Volute
    Zhang, Ning
    Yang, MinGuan
    Gao, Bo
    Li, Zhong
    Ni, Dan
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (06):