Effects of modeling strategies of triply periodic minimal surface on the mechanical properties and permeability of biomedical TC4 porous scaffolds

被引:1
|
作者
Wang, Binghao [1 ,2 ]
Yang, Chengliang [1 ,2 ]
Zheng, Chuanchuan [1 ,2 ]
Luo, Miao [1 ,2 ]
Shi, Zheng [3 ]
Lv, Yuting [3 ]
Peng, Wen [4 ]
Wang, Liqiang [5 ,6 ]
机构
[1] Youjiang Med Univ Nationalities, Affiliated Hosp, Baise, Guangxi, Peoples R China
[2] Guangxi Hlth Commiss, Guangxi Biomed Mat Engn Res Ctr Bone & Joint Degen, Guangxi Key Lab Basic & Translat Res Bone & Joint, Key Lab Biomed Mat Res,Key Lab Clin Med Res Bone &, Baise, Guangxi, Peoples R China
[3] Shandong Univ Sci & Technol, Coll Mech & Elect Engn, Qingdao, Shandong, Peoples R China
[4] Orthoped Implant Stable Engn Technol Res Ctr, Foshan, Guangdong, Peoples R China
[5] Shanghai Jiao Tong Univ, State Key Lab Met Matrix Composites, Shanghai, Peoples R China
[6] Shanghai Jiao Tong Univ, Natl Ctr Translat Med, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Porous scaffolds; Triply periodic minimal surface; Mechanical performance; Modeling strategies; TITANIUM; IMPLANTS; DESIGN; PERFORMANCE; MORPHOLOGY; REDUCTION; BEHAVIOR; POROSITY; ALLOY;
D O I
10.36922/ijb.2565
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Modeling strategies play a crucial role in determining the unit shapes of triply periodic minimal surface (TPMS), significantly affecting the mechanical and permeability properties of porous scaffolds. In this study, two distinct strategies including surface thickening and surface filling were used to construct scaffold models based on four basic TPMS structures (Primitive [P], Gyroid [G], Diamond [D], and I -graphwrapped package [IW-P]). These models were successfully prepared using TC4 alloy and selective laser melting technology. Macro/micro morphology, mechanical properties, and permeability tests of porous implants were carried out. The results indicate that the scaffolds effectively replicated the designed models, exhibiting mechanical properties that match those of human tissue. The elastic modulus ranges from 3.03 to 4.57 GPa, and the tensile strength varies between 135.78 and 250.90 MPa. The surface thickening strategy alters the material distribution within the unit, enhancing load uniformity on the scaffolds, thereby increasing the strength of the scaffolds with G, D, and IW-P units, while reducing stress fluctuations during compression. In contrast, the surface filling structure exhibits excellent permeability, with permeability rates falling within the range of 0.88 to 1.91 x 10 -9 m 2 , aligning with the permeability performance of trabecular bone. This study offers new insights into the design of porous scaffold models tailored for various application scenarios.
引用
收藏
页码:426 / 441
页数:16
相关论文
共 50 条
  • [41] Static and dynamic performance of porous Ti6Al4V tibia implant designs based on triply periodic minimal surface scaffolds
    Eltlhawy, Basma
    Fouda, Noha
    Eldesouky, Ibrahim
    MECCANICA, 2025, : 999 - 1014
  • [42] Study on bioactivity of SLMed variable gradient TC4 biomedical porous scaffolds with micro-arc oxidation treatment
    Lv, Yuting
    Guo, Jiawei
    Huang, Weimin
    Liu, Yaojie
    Liu, Wentao
    Wei, Guijiang
    ANTI-CORROSION METHODS AND MATERIALS, 2022, 69 (06) : 660 - 666
  • [43] Mechanical properties of hybrid structures generated by additively manufactured triply periodic minimal surface structures and foam
    Miralbes, R.
    Pascual, F. J.
    Ranz, D.
    Gomez, J. A.
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2023, 30 (21) : 4317 - 4328
  • [44] Mechanical Properties of Triply Periodic Minimal Surface Structures Mimicking the Microstructure of Woodpecker's Cranial Bone
    Ni, Yikun
    Wang, Lizhen
    Fan, Yubo
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1873 - 1876
  • [45] QUASI-STATIC AND DYNAMIC MECHANICAL PROPERTIES OF FUNCTIONALLY GRADED TRIPLY PERIODIC MINIMAL SURFACE STRUCTURES
    Cheng, Qian
    Yin, Jianfei
    Wen, Jihong
    Yu, Dianlong
    Lixue Xuebao/Chinese Journal of Theoretical and Applied Mechanics, 2024, 56 (09): : 2646 - 2658
  • [46] Effect of residual stress on mechanical properties of Triply periodic minimal surface lattice structures in Additive manufacturing
    Huang, Xinyu
    Tang, Huayuan
    Wang, Lei
    COMPUTATIONAL MATERIALS SCIENCE, 2024, 245
  • [47] Experimental Forced Convection Study Using a Triply Periodic Minimal Surface Porous Structure with a Nanofluid: Comparison with Numerical Modeling
    Saghir, Mohamad Ziad
    Kilic, Gulenay Alevay
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [48] Effects of Different Cooling Methods on Microstructure and Mechanical Properties of TC4 Alloy
    Ou, Meigui
    Zhang, Song
    Song, Hongchao
    Liang, Yilong
    HIGH PERFORMANCE STRUCTURAL MATERIALS, 2018, : 539 - 547
  • [49] Effects on mechanical properties of TC4 welding line by laser shock processing
    School of Mechanical Engineering, Jiangsu University, Zhenjiang 212013, China
    不详
    Jiangsu Daxue Xuebao Ziran Kexue Ban J. Jiangsu Univ. Nat. Sci. Ed., 2006, 3 (207-210):
  • [50] Impact of Engineering Surface Treatment on Surface Properties of Biomedical TC4 Alloys under a Simulated Human Environment
    Deng, Hongyun
    Xu, Kuixue
    Liu, Shuguang
    Zhang, Chaofeng
    Zhu, Xiongwei
    Zhou, Haoran
    Xia, Chaoqun
    Shi, Chunbao
    COATINGS, 2022, 12 (02)