Dosimetric impact of respiratory motion on proximal bronchial tree during lung cancer stereotactic body radiation therapy: A patient-specific phantom study

被引:0
|
作者
Kim, Dae Hyun [1 ]
Ko, Young Eun [1 ]
Je, Hyoung U. K. [1 ]
机构
[1] Ulsan Univ Hosp, Dept Radiat Oncol, 873 Bangeohnsunhwando Ro, Ulsan 44033, South Korea
关键词
Centrally located lung cancer; Proximal bronchial tree; Stereotactic body radiotherapy; Glass dosimeter; Patient-specific phantom; MANAGEMENT; RADIOTHERAPY; ACCURACY; TUMORS;
D O I
10.1016/j.jrras.2024.101000
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction: The respiratory motion of the proximal bronchial tree (PBT) adjacent to the tumor is not taken into consideration in the treatment plan, and there is a risk that the PBT may be irradiated with a higher dose. Therefore, this study aimed to measure the PBT dose directly using patient-specific phantoms of patients treated with SBRT for a centrally located lung tumor and to determine the dose variation with the respiratory motion of the PBT. Materials and methods: This study included 10 patients who received SBRT for central lung tumors. We utilized patient-specific tumor phantoms fabricated with a three-dimensional printer using the patient's computed tomography (CT) data to analyze the dose variation in PBT owing to respiratory motion. Two SBRT plans were generated: a full-phase plan and a 30-70 gating plan. Dose measurements were performed using glass dosimeters. We measured the dose three times for each plan, with the phantom either in motion or fixed at the 50% phase. Results: We analyzed the target volumes and measured doses for each SBRT plan. Compared with the gross tumor volume on the 50% phase CT image, the internal target volume was larger by approximately 13.1% and 45.9% during the 30-70% phase and full phases CT images, respectively. Similarly, the planning target volumes increased by 9.3% and 34.4%, respectively. The average variations in the measured dose of the glass dosimeter owing to patient-specific motion were 3.85% for the full-phase plans and 1.92% for the 30-70 gating plans. Conclusion: Respiratory motion can affect the absorbed dose of the PBT, and this effect is particularly pronounced when the PBT is near the tumor. The gating method reduces the degree of dose variation. This study highlights the importance of understanding the respiratory motion of the PBT in SBRT for centrally located lung tumors.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Respiratory motion-management in stereotactic body radiation therapy for lung cancer - A dosimetric comparison in an anthropomorphic lung phantom (LuCa)
    Ehrbar, Stefanie
    Perrin, Rosalind
    Peroni, Marta
    Bernatowicz, Kinga
    Parkel, Thomas
    Pytko, Izabela
    Klock, Stephan
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    Weber, Damien Charles
    Lomax, Antony
    RADIOTHERAPY AND ONCOLOGY, 2016, 121 (02) : 328 - 334
  • [2] Dosimetric effects of respiratory motion during stereotactic body radiation therapy of lung tumors
    Sarudis, Sebastian
    Karlsson, Anna
    Nyman, Jan
    Back, Anna
    ACTA ONCOLOGICA, 2022, 61 (08) : 1004 - 1011
  • [3] Patient-specific Quantification of the Dosimetric Impact of Motion During Radiation Therapy: A Clinically Usable Tool
    Ruan, D.
    Shao, W.
    DeMarco, J.
    King, C.
    Agazaryan, N.
    Low, D.
    Kupelian, P.
    Steinberg, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S84 - S84
  • [4] Patient-specific motion and treatment margins in pancreatic stereotactic body radiation therapy
    Miften, M.
    Jones, B. L.
    Fukami, N.
    Schefter, T.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S198 - S199
  • [5] Tumor Volume Variations and Related Dosimetric Impact During Stereotactic Body Radiation Therapy for Lung Cancer
    Moretti, Luigi
    Jourani, Younes
    Charlier, Florian
    De Brouwer, Thomas
    Van Houtte, Paul
    JOURNAL OF THORACIC ONCOLOGY, 2015, 10 (09) : S327 - S327
  • [6] Dosimetric comparison of patient setup strategies in stereotactic body radiation therapy for lung cancer
    Wu, Jianzhou
    Betzing, Christopher
    He, Tongming T.
    Fuss, Martin
    D'Souza, Warren D.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [7] Patient-specific tumor and respiratory monitoring phantom design for quality controls of stereotactic ablative body radiotherapy in lung cancer cases
    Erdogan, Taha
    Fidan, Ugur
    Ozyigit, Gokhan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 90 : 40 - 49
  • [8] Stereotactic body radiation therapy (SBRT) and respiratory gating in lung cancer: dosimetric and radiobiological considerations
    Herman, Tania De La Fuente
    Vlachaki, Maria T.
    Herman, Terence S.
    Hibbitts, Kerry
    Stoner, Julie A.
    Ahmad, Salahuddin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01): : 158 - 169
  • [9] Fatal complications after stereotactic body radiation therapy for central lung tumors abutting the proximal bronchial tree
    Haseltine, Justin M.
    Rimner, Andreas
    Gelblum, Daphna Y.
    Modh, Ankit
    Rosenzweig, Kenneth E.
    Jackson, Andrew
    Yorke, Ellen D.
    Wu, Abraham J.
    PRACTICAL RADIATION ONCOLOGY, 2016, 6 (02) : E27 - E33
  • [10] Development of a Machine Learning Methodology to Estimate Lung Stereotactic Body Radiation Therapy Dosimetric Endpoints Based on Patient-Specific Anatomic Features
    Lafata, K.
    Cai, J.
    Ren, L.
    Wu, Q.
    Hong, J. C.
    Kelsey, C. R.
    Yin, F. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E420 - E421