An integrated sample-to-answer graphene microchip for ultrafast detection of multiple microorganisms

被引:1
|
作者
Fu, Quanying [1 ]
Feng, Shaoqiong [1 ]
Xiao, Zihan [1 ]
Gong, Keye [1 ]
Pang, Xueyuan [1 ]
Yang, Yuxiao [1 ]
Zhou, Cuiping [2 ]
Liu, Haidong [1 ]
Wang, Jiasi [1 ]
Zhou, Jianhua [1 ]
机构
[1] Sun Yat Sen Univ, Sch Biomed Engn, Guangdong Prov Key Lab Sensing Technol & Biomed In, Shenzhen Campus, Shenzhen 518107, Peoples R China
[2] Southern Med Univ, Nanfang Hosp, Dept Emergency, Guangzhou 510515, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Nucleic acid detection; Integrated detection; Sample; -to; -answer; Graphene microchip; Multiple microorganism detection; CHIP; AMPLIFICATION; DEVICE;
D O I
10.1016/j.snb.2024.135584
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The integrated detection of nucleic acids is a molecular biological technology integrating the entire process of nucleic acid detection into a "sample-to-answer" system, which is widely used in microbial identification and disease diagnosis. Although the integrated detection of nucleic acids has the advantages of fully-enclosed system and simple operation, it still faces challenges like dependence on bulky equipment, complex design, and long detection time. To address these challenges, we have proposed and fabricated an integrated graphene microchip for ultra-fast detection of multiple microorganisms. This microchip is composed of two main regions: the electrolysis-extraction region and the isothermal amplification-detection region. In the electrolysis-extraction region, the microchip was equipped with the micron-structured graphene interdigital electrode and a regular battery for power supply, and the nucleic acids of H. pylori were extracted only in 1.0 s by electrolysis. Then in the isothermal amplification-detection region, the nucleic acids of H. pylori were detected in less than 9 min at a concentration of 10 CFU/mu L. As a result, the detection time of the whole process were controlled in merely 9 min. In addition, this integrated graphene microchip has three parallel channels for simultaneous detection of oral microorganisms, e.g., C. albicans, S. aureus and H. pylori. These characteristics make our integrated graphene microchip promising to contribute to the development in integrated technology of nucleic acid detection and be widely used at various medical structures or on-site environments such as home testing.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Miniaturized electrophoresis: An integrated microfluidic cartridge with functionalized hydrogel-assisted LAMP for sample-to-answer analysis of nucleic acid
    Kumar, Natish
    Kumari, Monika
    Chander, Devtulya
    Dogra, Sandeep
    Chaubey, Asha
    Arun, Ravi Kumar
    BIOMICROFLUIDICS, 2024, 18 (06)
  • [42] A fully automated sample-to-answer PCR system for easy and sensitive detection of dengue virus in human serum and mosquitos
    Tsai, Jih-Jin
    Liu, Wei-Liang
    Lin, Ping-Chang
    Huang, Bo-Yi
    Tsai, Ching-Yi
    Lee, Pei-Yu Alison
    Tsai, Yun-Long
    Chou, Pin-Hsing
    Chung, Simon
    Liu, Li-Teh
    Chen, Chun-Hong
    PLOS ONE, 2019, 14 (07):
  • [43] "Sample-to-Answer" Detection of Rare ctDNA Mutation from 2 mL Plasma with a Fully Integrated DNA Extraction and Digital Droplet PCR Microdevice for Liquid Biopsy
    Geng, Zhi
    Li, Shanglin
    Zhu, Lingxiang
    Cheng, Zhen
    Jin, Min
    Liu, Baoxia
    Guo, Yong
    Liu, Peng
    ANALYTICAL CHEMISTRY, 2020, 92 (10) : 7240 - 7248
  • [44] Direct, ultrafast, and sensitive detection of environmental pathogenic microorganisms based on a graphene biosensor
    Du, Manman
    Ma, Jinbiao
    Zhang, Zhiwei
    Wu, Guangzu
    Wu, Jianguo
    Wang, Hao
    Xie, Xinwu
    Wang, Can
    ANALYTICA CHIMICA ACTA, 2023, 1279
  • [45] LASER-ACTUATED CENTRIFUGO-PNEUMATIC FLOW CONTROL TOWARDS 'SAMPLE-TO-ANSWER' INTEGRATED DETECTION OF MULTI-MARKER PANELS AT THE POINT-OF-CARE
    Mishra, Rohit
    Reilly, Glen
    Agnew, Matthew
    Garvey, Alexander
    Rogers, Chiral
    Andrade, Elaine
    Ma, Hui
    Fitzgerald, Sean
    Zapatero, Julia
    O'Kennedy, Richard
    Ducree, Jens
    2018 IEEE MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2018, : 1185 - 1188
  • [46] Nasopharyngeal Swab Sample-to-Answer Detection of Adenovirus, Parainfluenza Virus, and hMPV Using Simplexa Respiratory Virus Direct Assay
    Gregson, H.
    Granados, J.
    Martin, R.
    Tabb, M.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2016, 18 (06): : 984 - 984
  • [47] A sample-to-answer, wearable cloth-based electrochemical sensor (WCECS) for point-of-care detection of glucose in sweat
    Zheng, Lin
    Liu, Yuan
    Zhang, Chunsun
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 343 (343):
  • [48] Origami-based "Book" shaped three-dimensional electrochemical paper microdevice for sample-to-answer detection of pathogens
    He, Tao
    Li, Jingwen
    Liu, Lisheng
    Ge, Shenguang
    Yan, Mei
    Liu, Haiyun
    Yu, Jinghua
    RSC ADVANCES, 2020, 10 (43) : 25808 - 25816
  • [49] Performance of a molecular diagnostic, multicode based, sample-to-answer assay for the simultaneous detection of Influenza A, B and Respiratory Syncytial Viruses
    Voermans, J.
    Deniz, S.
    Koopmans, M.
    van der Eijk, A.
    Pas, S.
    JOURNAL OF CLINICAL VIROLOGY, 2016, 82 : S34 - S34
  • [50] Sample-to-answer microfluidic device towards the point-of-need detection of Staphylococcus aureus enterotoxin genes in ruminant milk
    Shalaby, Maha
    Busin, Valentina
    Yan, Xiaoxiang
    Cengiz, Seyda
    Adiguzel, Mehmet Cemal
    Cooper, Jonathan M.
    Forde, Taya
    Reboud, Julien
    LAB ON A CHIP, 2025, 25 (04) : 524 - 535