Comparison of wear and fracture resistance of additively and subtractively manufactured screw-retained, implant-supported crowns

被引:11
|
作者
Turksayar, Almira Ada Diken [1 ,2 ]
Demirel, Munir [3 ]
Donmez, Mustafa Borga [1 ,4 ]
Olcay, Emin Orkun [1 ]
Eyuboglu, Tan Firat [5 ]
Ozcan, Mutlu [6 ]
机构
[1] Biruni Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[2] Carinthia Univ Appl Sci, ADMiRE Res Ctr Addit Mfg Intelligent Robot Sensors, Sch Engn & IT, Villach, Austria
[3] Biruni Univ, Vocat Sch, Oral & Dent Hlth, Istanbul, Turkiye
[4] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3007 Bern, Switzerland
[5] Istanbul Medipol Univ, Fac Dent, Dept Endodont, Istanbul, Turkiye
[6] Univ Zurich, Ctr Dent Med, Clin Masticatory Disorders & Dent Biomat, Zurich, Switzerland
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 132卷 / 01期
关键词
ZIRCONIA; PERFORMANCE; SURVIVAL;
D O I
10.1016/j.prosdent.2023.06.017
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Additively manufactured resins indicated for fixed definitive prostheses have been recently marketed. However, knowledge on their wear and fracture resistance when fabricated as screw-retained, implant-supported crowns and subjected to artificial aging is limited. Purpose. The purpose of this in vitro study was to evaluate the volume loss, maximum wear depth, and fracture resistance of screwretained implant-supported crowns after thermomechanical aging when fabricated using additively and subtractively manufactured materials. Material and methods. Two additively manufactured composite resins (Crowntec [CT] and VarseoSmile Crown Plus [VS]) and 2 subtractively manufactured materials (1 reinforced composite resin, Brilliant Crios [BC] and 1 polymer-infiltrated ceramic network, Vita Enamic [EN]) were used to fabricate standardized screw-retained, implant-supported crowns. After fabrication, the crowns were cemented on titanium base abutments and then tightened to implants embedded in acrylic resin. A laser scanner with a triangular displacement sensor (LAS -20) was used to digitize the pre-aging state of the crowns. Then, all crowns were subjected to thermomechanical aging (1.2 million cycles under 50 N) and rescanned. A metrology-grade analysis software program (Geomagic Control X 2020.1) was used to superimpose post-aging scans over pre-aging scans to calculate the volume loss (mm3) and maximum wear depth (mm). Finally, all crowns were subjected to a fracture resistance test. Fracture resistance and volume loss were evaluated by using 1-way analysis of variance and Tukey Honestly significant difference (HSD) tests, whereas the Kruskal-Wallis and Dunn tests were used to analyze maximum wear depth. Chisquared tests were used to evaluate the Weibull modulus and characteristic strength data (alpha=.05). Results. Material type affected the tested parameters (P .001). CT and VS had higher volume loss and maximum wear depth than BC and EN (P .001). EN had the highest fracture resistance among tested materials (P .001), whereas BC had higher fracture resistance than CT (P=.011). The differences among tested materials were not significant when the Weibull modulus was considered (P=.199); however, VE had the highest characteristic strength (P .001). Conclusions. Additively manufactured screw-retained, implant-supported crowns had higher volume loss and maximum wear depth. All materials had fracture resistance values higher than the previously reported masticatory forces of the premolar region; however, the higher characteristic strength of the subtractively manufactured polymer-infiltrated ceramic network may indicate its resistance to mechanical complications. (J Prosthet Dent 2024;132:154-164)
引用
收藏
页码:154 / 164
页数:11
相关论文
共 50 条
  • [1] A comparison of the porcelain fracture resistance of screw-retained and cement-retained implant-supported metal-ceramic crowns
    Torrado, E
    Ercoli, C
    Al Mardini, M
    Graser, GN
    Tallents, RH
    Cordaro, L
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (06): : 532 - 537
  • [2] Porcelain Fracture Resistance of Screw-Retained, Cement-Retained, and Screw-Cement-Retained Implant-Supported Metal Ceramic Posterior Crowns
    Al-Omari, Wael M.
    Shadid, Rola
    Abu-Naba'a, Layla
    El Masoud, Bilal
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (04): : 263 - 273
  • [3] Mechanical Behavior and Fracture Loads of Screw-Retained and Cement-Retained Lithium Disilicate Implant-Supported Crowns
    Camatta, Hercules Pessin
    Ferreira, Rodrigo Melim
    Ferrairo, Brunna Mota
    Strelhow, Samira Sandy
    Rubo, Jose Henrique
    Mori, Aline Akemi
    Ferruzzi, Fernanda
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (08): : 690 - 697
  • [4] Aging and Fracture Resistance of Screw-Retained Implant-Supported Molar Crowns Fabricated from Lithium Disilicate Containing Virgilite
    Rauch, Angelika
    Schmid, Alois
    Schmidt, Michael Benno
    Schmutzler, Anne
    Hahnel, Sebastian
    Rosentritt, Martin
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (04) : 453 - 456
  • [5] Fracture resistance of implant-supported screw-retained zirconia-based molar restorations
    Honda, Junichi
    Komine, Futoshi
    Kamio, Shingo
    Taguchi, Kohei
    Blatz, Markus B.
    Matsumura, Hideo
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (09) : 1119 - 1126
  • [6] A TECHNIQUE FOR FABRICATING SINGLE SCREW-RETAINED IMPLANT-SUPPORTED INTERIM CROWNS IN CONJUNCTION WITH IMPLANT SURGERY
    McRory, M. Eric
    Cagna, David R.
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (06): : 455 - 459
  • [7] Effect of different tightening protocols on the probability of survival of screw-retained implant-supported crowns
    Fardin, Vinicius P.
    Bergamo, Edmara T. P.
    Bordin, Dimorvan
    Hirata, Ronaldo
    Bonfante, Estevam A.
    Bonfante, Gerson
    Coelho, Paulo G.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 126
  • [8] New abutment for a screw-retained, implant-supported crown
    Prisco, R
    Morgano, SM
    D'Amato, S
    JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (01): : 30 - 33
  • [9] Fracture resistance of additive manufactured and milled implant-supported interim crowns
    Martin-Ortega, Nuria
    Sallorenzo, Alessandro
    Casajus, Javier
    Cervera, Alberto
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02): : 267 - 274
  • [10] A maxillary screw-retained, implant-supported diagnostic wax pattern
    Proussaefs, P
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (04): : 403 - 406