Numerical study on the seismic performance of phosphogypsum-filled cold-formed thin-walled steel composite walls

被引:3
|
作者
Hu, Song [1 ]
Chen, Zongping [3 ]
Ke, Xiaojun [3 ]
Zhou, Li [2 ]
机构
[1] Tongren Univ, Coll Agr & Forestry Engn & Planning, Tongren 554300, Peoples R China
[2] Guizhou Univ, Coll Architecture & Urban Planning, Guiyang 550025, Peoples R China
[3] Guangxi Univ, Coll Civil Engn & Architecture, Nanning 530004, Peoples R China
基金
中国国家自然科学基金;
关键词
Phosphogypsum; Cold -formed steel; Composite wall; Lateral resistance; Numerical investigation; SHEAR WALLS; FOAMED CONCRETE; BEHAVIOR; GYPSUM;
D O I
10.1016/j.tws.2024.111982
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To conduct in-depth research on the seismic performance of phosphogypsum (PG) filled cold-formed thin-walled square steel tube (PFCFS) composite walls, a series of finite element analyses were conducted using the software ABAQUS. The study examined various factors, including PG strength, oriented strand board (OSB) configuration and thickness, stud strength and thickness, screw spacing, axial force ratio, wall sheathing coverage, and heightwidth ratio. After summarizing, the main findings are as follows: the lateral behavior of walls is significantly affected by PG strength and wall stud thickness, while wall sheathing configuration has a relatively low impact; increasing PG strength, wall stud thickness and strength, wall sheathing thickness, axial force ratio, and the number of wall sheathings (non vs. single vs. double sheathing), or decreasing self-tapping screw spacing and wall height-width ratio enhance the shear capacity of the wall; increasing PG strength, wall sheathing thickness, or reducing wall height-width ratio improve the lateral stiffness and ductility of the wall; increasing wall stud thickness and adding more wall sheathing can improve the lateral stiffness of the wall. However, this can reduce the wall's ductility; by decreasing self-tapping screw spacing or increasing axial force ratio, the lateral stiffness and ductility of the wall exhibit an increasing-then-decreasing trend; increasing wall stud strength does not significantly affect the lateral stiffness of the wall, but it does decrease the ductility. Finally, the simulated lateral stiffness and shear capacity of the wall were compared with the theoretical values, which showed good agreement.
引用
收藏
页数:18
相关论文
共 50 条
  • [11] Experimental study on seismic behavior of prefabricated cold-formed thin-walled steel-foam concrete composite walls
    Peng Z.
    Chen Z.
    Xu Z.
    Huang Y.
    Luo Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2024, 45 (07): : 177 - 188
  • [12] Experimental study on seismic behavior of full-scale composite walls with cold-formed thin-walled steel tubular truss
    Wang, J. (jfwang008@163.com), 1600, Chinese Society of Civil Engineering (46):
  • [13] Study on Cold-Formed Steel of Thin-Walled Housing for Dynamic Performance
    Yao, Yong
    Chu, Yunpeng
    Wang, Li
    Zhao, Rui
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 3305 - 3308
  • [14] Seismic Response Investigation and Nonlinear Numerical Analysis of Cold-Formed Thin-Walled Steel Tube Truss Shear Walls
    Wang, Jingfeng
    Wang, Wanqian
    Pang, Shuai
    Yu, Bo
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2019, 19 (05) : 1662 - 1681
  • [15] Seismic Response Investigation and Nonlinear Numerical Analysis of Cold-Formed Thin-Walled Steel Tube Truss Shear Walls
    Jingfeng Wang
    Wanqian Wang
    Shuai Pang
    Bo Yu
    International Journal of Steel Structures, 2019, 19 : 1662 - 1681
  • [16] Study on shear performance of cold-formed thin-walled steel walls sheathed by paper straw board
    Zhang, Xiuhua
    Zhang, Enyuan
    Zhang, Yizhuo
    ENGINEERING STRUCTURES, 2021, 245
  • [17] Experimental study on the seismic performance of a cold-formed thin-walled steel–concrete composite column-H steel beam frame
    HongJie Hou
    ZhiHua Chen
    XiuLi Wang
    Scientific Reports, 13
  • [18] Bending performance of cold-formed thin-walled steel-glulam composite beams
    Yang, Hai-Xu
    Guo, Yue
    Wang, Hai-Biao
    Hu, Yi
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2024, 54 (12): : 3513 - 3525
  • [19] Experimental Study on Seismic Behavior of Cold-formed Thin-walled Steel RCShear Wall
    Xu, Ming
    Yao, Yongqin
    Chen, Liang
    Chen, Zhongfan
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 708 - 713
  • [20] Seismic behavior of cold-formed thin-walled steel plate shear wall
    Zhou X.
    Zou Y.
    Xu L.
    Yao X.
    Shi Y.
    Guan Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (05): : 65 - 75