Investigation of long-term stability of a transmission Raman calibration model using orthogonal projection methods

被引:0
|
作者
Pedge, Nicholas I. [1 ]
Papillaud, Matthieu [2 ]
Roger, Jean-Michel [3 ,4 ]
机构
[1] AstraZeneca, Pharmaceut Technol & Dev, Chem Dev, Operat, Macclesfield, England
[2] AstraZeneca, Pharmaceut Technol & Dev, Operat, Macclesfield, England
[3] UMR ITAP INRAE SupAgro, Montpellier, France
[4] ChemHouse Res Grp, Montpellier, France
关键词
Spectrometers; -; Transmissions;
D O I
10.1016/j.chemolab.2024.105115
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Transmission Raman Spectroscopy (TRS) was implemented as an 'Extended ' Content Uniformity (ECU) method for un-coated tablets for a commercial pharmaceutical product. By sampling un-coated tablets throughout the duration of the tablet compression stage, it can be demonstrated that the material from the preceding blend step was of uniform composition, and therefore the blend and compression unit -operations were in a state of control. TRS was selected as a rapid, nondestructive measurement that can be automated through the use of a sample tray that can hold many tablets. In this work, the performance of a multivariate calibration model (PLS) deployed to two Transmission Raman Spectrometers co -located within the same QC laboratory was studied using data obtained over a 3 -year period. The aim of the investigation was to assess the impact of various annual instrument maintenance events, and to evaluate several chemometric methods for reducing or eliminating the spectral effects that led to deterioration of a models performance. Linear orthogonal projection approaches such as Transfer by Orthogonal Projection (TOP), Dynamic Orthogonal Projection (DOP) and Unsupervised Dynamic Orthogonal Projection (uDOP) were applied, along with a more recent, non-linear method called Transfer Component Analysis -Orthogonal Projection (TCA-OP). This works shows that each method has merits, depending on the nature of the spectral/model correction required. In most cases, the model performance could be fully restored, or significantly improved. This work also highlights how these various methods can be useful tools to better understand the root -cause for a deterioration in model performance.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Long-Term Voltage Stability Assessment of an Integrated Transmission Distribution System
    Singhal, Ankit
    Ajjarapu, Venkataramana
    2017 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2017,
  • [22] VERY LONG-TERM STABILITY OF THIN INDIUM TIN FILM TRANSMISSION
    HURWITZ, M
    LABOV, S
    CHAKRABARTI, S
    APPLIED OPTICS, 1985, 24 (12): : 1735 - 1736
  • [23] Long-term stability of the wavelength method of height scale calibration for interference microscopy
    Fitzgerald, Danette
    de Groot, Peter
    APPLIED OPTICAL METROLOGY III, 2019, 11102
  • [24] Improvement of methods for long-term transmission systems expansion in current conditions
    Drachev, P. S.
    Trufanov, V. V.
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [25] Investigation of the long-term variation of gravity waves over South America using empirical orthogonal function analysis
    Ayorinde, Toyese Tunde
    Wrasse, Cristiano Max
    Takahashi, Hisao
    Barros, Diego
    Figueiredo, Cosme Alexandre Oliveira Barros
    da Silva, Ligia Alves
    Bilibio, Anderson Vestena
    EARTH PLANETS AND SPACE, 2024, 76 (01):
  • [26] Erratum to: A Study of Soil Organic Matter Stability Using Derivatography and Long-Term Incubation Methods
    D. A. Sokolov
    I. I. Dmitrevskaya
    N. B. Pautova
    T. N. Lebedeva
    V. A. Chernikov
    V. M. Semenov
    Eurasian Soil Science, 2021, 54 : 1130 - 1130
  • [27] Improving long-term projection in nipple reconstruction using human acellular dermal matrix - An animal model
    Holton, LH
    Haerian, H
    Silverman, RP
    Chung, T
    Elisseeff, JH
    Goldberg, NH
    Slezak, S
    ANNALS OF PLASTIC SURGERY, 2005, 55 (03) : 304 - 309
  • [28] CHOPIN, A HEURISTIC MODEL FOR LONG-TERM TRANSMISSION EXPANSION PLANNING
    LATORREBAYONA, G
    PEREZARRIAGA, IJ
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1994, 9 (04) : 1886 - 1894
  • [29] Calibration of Transition Intensities for a Multistate Model: Application to Long-Term Care
    Esquivel, Manuel L.
    Guerreiro, Gracinda R.
    Oliveira, Matilde C.
    Corte Real, Pedro
    RISKS, 2021, 9 (02) : 1 - 17
  • [30] Improvement of calibration models using two successive orthogonal projection methods. Application to quantification of wine mannoproteins
    Boulet, J. C.
    Doco, T.
    Roger, J. M.
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2007, 87 (02) : 295 - 302