Investigation of long-term stability of a transmission Raman calibration model using orthogonal projection methods

被引:0
|
作者
Pedge, Nicholas I. [1 ]
Papillaud, Matthieu [2 ]
Roger, Jean-Michel [3 ,4 ]
机构
[1] AstraZeneca, Pharmaceut Technol & Dev, Chem Dev, Operat, Macclesfield, England
[2] AstraZeneca, Pharmaceut Technol & Dev, Operat, Macclesfield, England
[3] UMR ITAP INRAE SupAgro, Montpellier, France
[4] ChemHouse Res Grp, Montpellier, France
关键词
Spectrometers; -; Transmissions;
D O I
10.1016/j.chemolab.2024.105115
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Transmission Raman Spectroscopy (TRS) was implemented as an 'Extended ' Content Uniformity (ECU) method for un-coated tablets for a commercial pharmaceutical product. By sampling un-coated tablets throughout the duration of the tablet compression stage, it can be demonstrated that the material from the preceding blend step was of uniform composition, and therefore the blend and compression unit -operations were in a state of control. TRS was selected as a rapid, nondestructive measurement that can be automated through the use of a sample tray that can hold many tablets. In this work, the performance of a multivariate calibration model (PLS) deployed to two Transmission Raman Spectrometers co -located within the same QC laboratory was studied using data obtained over a 3 -year period. The aim of the investigation was to assess the impact of various annual instrument maintenance events, and to evaluate several chemometric methods for reducing or eliminating the spectral effects that led to deterioration of a models performance. Linear orthogonal projection approaches such as Transfer by Orthogonal Projection (TOP), Dynamic Orthogonal Projection (DOP) and Unsupervised Dynamic Orthogonal Projection (uDOP) were applied, along with a more recent, non-linear method called Transfer Component Analysis -Orthogonal Projection (TCA-OP). This works shows that each method has merits, depending on the nature of the spectral/model correction required. In most cases, the model performance could be fully restored, or significantly improved. This work also highlights how these various methods can be useful tools to better understand the root -cause for a deterioration in model performance.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Long-term stability of rhinomanometer calibration
    Sipila, J
    Suonpaa, J
    JOURNAL OF OTOLARYNGOLOGY, 1997, 26 (01): : 49 - 52
  • [2] On the long-term stability of microwave radiometers using noise diodes for calibration
    Brown, Shannon T.
    Desai, Shailen
    Lu, Wenwen
    Tanner, Alan B.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2007, 45 (07): : 1908 - 1920
  • [3] MANPOWER IN A LONG-TERM ECONOMIC PROJECTION MODEL
    DARMSTADTER, J
    INDUSTRIAL RELATIONS, 1966, 5 (03): : 28 - 53
  • [4] On the long-term stability of calibration standards in different matrices
    Kandic, A.
    Vukanac, I.
    Djurasevic, M.
    Novkovic, D.
    Seslak, B.
    Milosevic, Z.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 1860 - 1862
  • [5] Bootstrap Decomposition Enhanced Orthogonal-Basis Projection Model for Long-term Time Series Forecasting
    Wang, Xiaoyu
    Xu, Pengyu
    Song, Mingyang
    Jing, Liping
    2023 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS, IJCNN, 2023,
  • [6] STABILITY AND LONG-TERM DURABILITY OF RAMAN-SPECTROSCOPY
    LAWSON, D
    SAMANTA, S
    MAGEE, PT
    GREGONIS, DE
    JOURNAL OF CLINICAL MONITORING, 1993, 9 (04): : 241 - 251
  • [7] ON THE ARBITRARILY LONG-TERM STABILITY OF CONSERVATIVE METHODS
    Wan, Andy T. S.
    Nave, Jean-Christophe
    SIAM JOURNAL ON NUMERICAL ANALYSIS, 2018, 56 (05) : 2751 - 2775
  • [8] INVESTIGATION OF THE LONG-TERM STABILITY OF SEVERAL MANGANINOMETERS
    KLINGENBERG, G
    PTB-MITTEILUNGEN, 1981, 91 (01): : 33 - 35
  • [9] CALIBRATION AND LONG-TERM STABILITY OF A PIXE SET-UP
    JOHANSSON, GI
    PALLON, J
    MALMQVIST, KG
    AKSELSSON, KR
    NUCLEAR INSTRUMENTS & METHODS, 1981, 181 (1-3): : 81 - 88
  • [10] Ensuring long-term stability of infrared camera absolute calibration
    Kattnig, Alain
    Thetas, Sophie
    Primot, Jerome
    OPTICS EXPRESS, 2015, 23 (14): : 18381 - 18390