摘要
Background: The Carlevale lens (FIL SSF, Soleko IOL Division, Italy) is a new lens for suture-less scleral fixation. This paper aimed to systematically review articles on this lens, the surgical techniques used for its implantation, complications and outcomes. Methods: This systematic review was performed following the PRISMA guidelines. The search string used was "Carlevale" AND "scleral fixation" from inception until March 2024. For completeness, either case-control studies, case reports or case series written in English were included. The authors used the Newcastle-Ottawa scale for the case-control studies and the JBI Critical Appraisal Checklist for case reports and case series. Results: Twenty-nine articles were included. Scleral fixation with Carlevale lens can be performed by creating scleral flaps or, alternatively, by using scleral pockets. The two sclerotomies must be diametrically opposed, and are preferably created by 25-gauge trocars. A pars plana vitrectomy should be performed every time, and the design of the lens should be suitable for self-anchoring to the sclera; the most accredited strategy to achieve this is to avoid scleral sutures. There were only a few intraoperative and postoperative complications reported; vitreous hemorrhages were the most frequent intraoperative events, while the most relevant postoperative complications were vitreous hemorrhages, cystoid macular oedema and transient variations in the intraocular pressure. Excellent results have been obtained in terms of BCVA, IOL centration and stability, mean intraocular pressure, postoperative spherical equivalent, separation between anterior and posterior chamber and the distance of the IOL from anterior chamber structures. Conclusions: The foldable hydrophilic design of the Carlevale lens has shown good effectiveness, IOL stability and few intra and post-operative complications.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Intraocular lens implantation in the absence of capsular support: scleral fixation
    Michael Tsatsos
    Georgios Vartsakis
    Ioannis Athanasiadis
    Marilita Moschos
    Soosan Jacob
    Eye, 2022, 36 : 1721 - 1723
  • [22] Secondary intraocular lens implantation using scleral suture fixation
    Szurman, P.
    Gekeler, K.
    OPHTHALMOLOGE, 2014, 111 (03): : 217 - 223
  • [23] Intraocular lens implantation in the absence of capsular support: scleral fixation
    Tsatsos, Michael
    Vartsakis, Georgios
    Athanasiadis, Ioannis
    Moschos, Marilita
    Jacob, Soosan
    EYE, 2022, 36 (09) : 1721 - 1723
  • [24] Scleral fixation of one piece intraocular lens by injector implantation
    Can, Ertugrul
    Basaran, Resat
    Gul, Adem
    Birinci, Hakki
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (08) : 857 - 860
  • [25] FUNCTIONAL RESULTS OF POSTERIOR CHAMBER LENS IMPLANTATION WITH SCLERAL FIXATION
    BLECKMANN, H
    KACZMAREK, U
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (03): : 321 - 326
  • [26] In-and-out technique for intraocular lens scleral fixation
    Choi, Jung Yeol
    Han, Young Keun
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1279 - 1284
  • [27] Scleral Fixation of Intraocular Lens with Ab Interno Technique
    Gurung, Nanda Kumari
    Rijal, Roshija
    Thapa, Bel Bahadur
    Gurung, Shanti
    JOURNAL OF NEPAL MEDICAL ASSOCIATION, 2017, 56 (206) : 234 - 237
  • [28] Novel surgical technique for sutureless scleral fixation of an intraocular lens using internal loops. "Shamil Technique"
    Louaya, Shamil
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 258 : e1 - e2
  • [29] A Systematic Review on Three Major Types of Scleral-Fixated Intraocular Lens Implantation
    Wong, Ho Ming
    Kam, Ka Wai
    Rapuano, Christopher J.
    Young, Alvin L.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2021, 10 (04): : 388 - 396
  • [30] Re: Scleral fixation of one piece intraocular lens by injector implantation
    Can, Ertugrul
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2015, 63 (05) : 466 - U112