Evaluating optimal quality assurance and quality control conditions of activation measurements at the accelerator-based boron neutron capture therapy system employing a lithium target

被引:1
|
作者
Suzuki, Shunsuke [1 ,2 ]
Yagihashi, Takayuki [1 ]
Nitta, Kazunori [1 ]
Yamanaka, Masashi [1 ]
Sato, Naoki [1 ]
Gotoh, Shinichi [1 ]
Sugimoto, Satoru [1 ,3 ]
Shiba, Shintaro [4 ]
Nagata, Hironori [1 ]
Tanaka, Hiroki [5 ]
机构
[1] Shonan Kamakura Gen Hosp, Dept Med Phys, 1370-1 Okamoto, Kamakura, Kanagawa 2478533, Japan
[2] Kyoto Univ, Kyoto Univ Katsura, Grad Sch Engn, Kyoto Nishikyo Ku, Kyoto 6158246, Japan
[3] Adv Data Sci Project, Med Data Math Reasoning Team, Informat R&D & Strategy Headquarters, RIKEN, 1-7-22 Suehiro Cho,Tsurumi Ku, Yokohama, Kanagawa 2300045, Japan
[4] Shonan Kamakura Gen Hosp, Dept Radiat Oncol, 1370-1 Okamoto, Kamakura, Kanagawa 2478533, Japan
[5] Kyoto Univ, Inst Integrated Radiat & Nucl Sci, Particle Radiat Oncol Res Ctr, 2 Asashiro Nish, Kumatori, Osaka 5900494, Japan
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2024年 / 10卷 / 04期
关键词
boron neutron capture therapy; quality assurance; quality control; high-purity germanium detector; activation measurement; RECURRENT; HEAD;
D O I
10.1088/2057-1976/ad4b1e
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Evaluating neutron output is important to ensure proper dose delivery for patients in boron neutron capture therapy (BNCT). It requires efficient quality assurance (QA) and quality control (QC) while maintaining measurement accuracy. This study investigated the optimal measurement conditions for QA/QC of activation measurements using a high-purity germanium (HP-Ge) detector in an accelerator-based boron neutron capture therapy (AB-BNCT) system employing a lithium target. The QA/QC uncertainty of the activation measurement was evaluated based on counts, reproducibility, and standard radiation source uncertainties. Measurements in a polymethyl methacrylate (PMMA) cylindrical phantom using aluminum-manganese (Al-Mn) foils and aluminum-gold (Al-Au) foils and measurements in a water phantom using gold wire with and without cadmium cover were performed to determine the optimal measurement conditions. The QA/QC uncertainties of the activation measurements were 4.5% for Au and 4.6% for Mn. The optimum irradiation proton charge and measurement time were determined to be 36 C and 900 s for measurements in a PMMA cylindrical phantom, 7.0 C and 900 s for gold wire measurements in a water phantom, and 54 C and 900 s at 0-2.2 cm depth and 3,600 s at deeper depths for gold wire measurements with cadmium cover. Our results serve as a reference for determining measurement conditions when performing QA/QC of activation measurements using HP-Ge detectors at an AB-BNCT employing a lithium target.
引用
收藏
页数:11
相关论文
共 38 条
  • [31] Evaluation of radioactivity in the bodies of mice induced by neutron exposure from an epi-thermal neutron source of an accelerator-based boron neutron capture therapy system
    Nakamura, Satoshi
    Imamichi, Shoji
    Masumoto, Kazuyoshi
    Ito, Masashi
    Wakita, Akihisa
    Okamoto, Hiroyuki
    Nishioka, Shie
    Iijima, Kotaro
    Kobayashi, Kazuma
    Abe, Yoshihisa
    Igaki, Hiroshi
    Kurita, Kazuyoshi
    Nishio, Teiji
    Masutani, Mitsuko
    Itami, Jun
    PROCEEDINGS OF THE JAPAN ACADEMY SERIES B-PHYSICAL AND BIOLOGICAL SCIENCES, 2017, 93 (10): : 821 - 831
  • [32] Acral cutaneous malignant melanoma treated with linear accelerator-based boron neutron capture therapy system: a case report of first patient
    Igaki, Hiroshi
    Nakamura, Satoshi
    Yamazaki, Naoya
    Kaneda, Tomoya
    Takemori, Mihiro
    Kashihara, Tairo
    Murakami, Naoya
    Namikawa, Kenjiro
    Nakaichi, Tetsu
    Okamoto, Hiroyuki
    Iijima, Kotaro
    Chiba, Takahito
    Nakayama, Hiroki
    Nagao, Ayaka
    Sakuramachi, Madoka
    Takahashi, Kana
    Inaba, Koji
    Okuma, Kae
    Nakayama, Yuko
    Shimada, Kazuaki
    Nakagama, Hitoshi
    Itami, Jun
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [33] Effect of magnetron sputtering power on structure and properties of Ta films on Cu substrate of neutron production target for accelerator-based boron neutron capture therapy (AB-BNCT)
    Xie, Yupeng
    Sun, Qiuyu
    Hu, Yaocheng
    Li, Jinglun
    Li, Xiaobo
    Jiang, Quanxu
    Wang, Jie
    Wang, Sheng
    VACUUM, 2024, 219
  • [34] Dependence of neutrons generated by 7Li(p,n) reaction on Li thickness under free-air condition in accelerator-based boron neutron capture therapy system employing solid-state Li target
    Nakamura, Satoshi
    Igaki, Hiroshi
    Okamoto, Hiroyuki
    Wakita, Akihisa
    Ito, Masashi
    Imamichi, Shoji
    Nishioka, Shie
    Iijima, Kotaro
    Nakayama, Hiroki
    Takemori, Mihiro
    Kobayashi, Kazuma
    Abe, Yoshihisa
    Okuma, Kae
    Takahashi, Kana
    Inaba, Koji
    Murakami, Naoya
    Nakayama, Yuko
    Nishio, Teiji
    Masutani, Mitsuko
    Itami, Jun
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 58 : 121 - 130
  • [35] Development of a 1.2 MV high voltage DC power supply with SF6 insulation for an electrostatic tandem proton accelerator in accelerator-based boron neutron capture therapy system
    Park, Chawon
    Kim, Minho
    Jung, Hyunwoo
    Park, Seungwoo
    Hong, Bong Hwan
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2025, 96 (02):
  • [36] The Anti-Tumor Effect of Boron Neutron Capture Therapy in Glioblastoma Subcutaneous Xenograft Model Using the Proton Linear Accelerator-Based BNCT System in Korea
    Seo, Il Hyeok
    Lee, Jeongwoo
    Na, Dasom
    Kyung, Hyunhye
    Yang, Jieun
    Lee, Sangbong
    Jeon, Sang June
    Choi, Jae Won
    Lee, Kyu Young
    Yi, Jungyu
    Han, Jaehwan
    Yoo, Mooyoung
    Kim, Se Hyun
    LIFE-BASEL, 2022, 12 (08):
  • [37] High-power electron beam tests of a liquid-lithium target and characterization study of 7Li(p,n) near-threshold neutrons for accelerator-based boron neutron capture therapy
    Halfon, S.
    Paul, M.
    Arenshtam, A.
    Berkovits, D.
    Cohen, D.
    Eliyahu, I.
    Kijel, D.
    Mardor, I.
    Silverman, I.
    APPLIED RADIATION AND ISOTOPES, 2014, 88 : 238 - 242
  • [38] Updated results of a phase II study evaluating accelerator-based boron neutron capture therapy (AB-BNCT) with borofalan(10B) (SPM-011) in recurrent squamous cell carcinoma (R-SCC-HN) and recurrent and locally advanced non-SCC (R/LA-nSCC-HN) of the head and neck
    Hirose, K.
    Konno, A.
    Yoshimoto, S.
    Ono, K.
    Otsuki, N.
    Hatazawa, J.
    Hiratsuka, J.
    Takai, Y.
    ANNALS OF ONCOLOGY, 2019, 30