A novel internal target volume definition based on velocity and time of respiratory target motion for external beam radiotherapy

被引:1
|
作者
Yamanaka, Masashi [1 ,2 ]
Nishio, Teiji [2 ]
Iwabuchi, Kohei [3 ]
Nagata, Hironori [1 ]
机构
[1] Shonan Kamakura Gen Hosp, Dept Med Phys, 1370-1 Okamoto, Kamakura, Kanagawa 2478533, Japan
[2] Osaka Univ, Grad Sch Med, Dept Med Phys & Engn, 1-7 Yamadaoka, Suita, Osaka 5650871, Japan
[3] Mizuho Res & Technol Ltd, 2-3 Kanda Nishikicho,Chiyoda Ku, Tokyo 1018443, Japan
关键词
Internal target volume; 4DCT; Target motion velocity; Time; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; STEREOTACTIC BODY RADIOTHERAPY; GUIDED RADIATION-THERAPY; INSPIRATION BREATH-HOLD; GATED RADIOTHERAPY; LUNG-TUMORS; LINEAR-ACCELERATOR; RESIDUAL MOTION; ARTIFACTS; TRACKING;
D O I
10.1007/s12194-024-00837-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aimed to develop a novel internal target volume (ITV) definition for respiratory motion targets, considering target motion velocity and time. The proposed ITV was evaluated in respiratory-gated radiotherapy. An ITV modified with target motion velocity and time (ITVvt) was defined as an ITV that includes a target motion based on target motion velocity and time. The target motion velocity was calculated using four-dimensional computed tomography (4DCT) images. The ITVvts were created from phantom and clinical 4DCT images. The phantom 4DCT images were acquired using a solid phantom that moved with a sinusoidal waveform (peak-to-peak amplitudes of 10 and 20 mm and cycles of 2-6 s). The clinical 4DCT images were obtained from eight lung cancer cases. In respiratory-gated radiotherapy, the ITVvt was compared with conventional ITVs for beam times of 0.5-2 s within the gating window. The conventional ITV was created by adding a uniform margin as the maximum motion within the gating window. In the phantom images, the maximum volume difference between the ITVvt and conventional ITV was -81.9%. In the clinical images, the maximum volume difference was -53.6%. Shorter respiratory cycles and longer BTs resulted in smaller ITVvt compared with the conventional ITV. Therefore, the proposed ITVvt plan could be used to reduce treatment volumes and doses to normal tissues.
引用
收藏
页码:843 / 853
页数:11
相关论文
共 50 条
  • [31] Target volume definition for intensity modulated whole pelvic radiotherapy (IMWPRT)
    Staffurth, J
    Adams, E
    Breen, S
    Sohaib, A
    Huddart, R
    Dearnaley, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S332 - S333
  • [32] Definition of accurate planning target volume margins for esophageal cancer radiotherapy
    Lesueur, P.
    Servagi-Vernat, S.
    CANCER RADIOTHERAPIE, 2016, 20 (6-7): : 651 - 656
  • [33] Impact of Radioimmunoscintigraphy on definition of clinical target volume for radiotherapy after prostatectomy
    Jani, AB
    Spelbring, D
    Hamilton, R
    Blend, MJ
    Pelizzari, C
    Brendler, C
    Krauz, L
    Vijayakumar, S
    Sapra, B
    Weichselbaum, RR
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (02) : 238 - 246
  • [34] Volumetric Differences in Clinical Target Volume (CTV) Vs Internal Target Volume (ITV) in Lung Cancer Radiotherapy
    Monroy Anton, J. L.
    Lopez-Munoz, M.
    Soler Tortosa, M.
    Candela Rodriguez, F.
    Melchor Iniguez, M.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S607 - S607
  • [35] A modeling study of functional magnetic resonance imaging to individualize target definition of seminal vesicles for external beam radiotherapy
    Damkjaer, Sidsel
    Thomsen, Jakob B.
    Petersen, Svetlana I.
    Bangsgaard, Jens Peter
    Petersen, Peter M.
    Vogelius, Ivan R.
    Aznar, Marianne C.
    ACTA ONCOLOGICA, 2017, 56 (06) : 799 - 805
  • [36] Evaluation of target dose based on water-equivalent thickness in external beam radiotherapy
    Moghaddam, Behnaz Ghanbar
    Vahabi-Moghaddam, Masoud
    Sadremomtaz, Alireza
    JOURNAL OF MEDICAL PHYSICS, 2013, 38 (01) : 44 - 51
  • [37] 4D-CT scan and radiotherapy for hepatocellular carcinoma: Role in the definition of internal target volume (ITV)
    De Bari, B.
    Sellal, N.
    Mornex, F.
    CANCER RADIOTHERAPIE, 2011, 15 (01): : 43 - 48
  • [38] Verifying internal target volume using cone-beam CT for stereotactic body radiotherapy treatment
    Wang, Z.
    Yin, F.
    Yoo, S.
    Wu, Q.
    Willett, C.
    Marks, L.
    MEDICAL PHYSICS, 2006, 33 (06) : 1991 - 1991
  • [39] Investigating different computed tomography techniques for internal target volume definition
    Yoganathan, S. A.
    Das, K. J. Maria
    Subramanian, V. Siva
    Raj, D. Gowtham
    Agarwal, Arpita
    Kumar, Shaleen
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2017, 13 (06) : 994 - 999
  • [40] Study on relation between location of target volume and respiratory motion
    Wang Suli
    Zheng Feng
    Feng Beibei
    Proceedings of the First International Symposium on Test Automation & Instrumentation, Vols 1 - 3, 2006, : 213 - 215