A novel internal target volume definition based on velocity and time of respiratory target motion for external beam radiotherapy

被引:1
|
作者
Yamanaka, Masashi [1 ,2 ]
Nishio, Teiji [2 ]
Iwabuchi, Kohei [3 ]
Nagata, Hironori [1 ]
机构
[1] Shonan Kamakura Gen Hosp, Dept Med Phys, 1370-1 Okamoto, Kamakura, Kanagawa 2478533, Japan
[2] Osaka Univ, Grad Sch Med, Dept Med Phys & Engn, 1-7 Yamadaoka, Suita, Osaka 5650871, Japan
[3] Mizuho Res & Technol Ltd, 2-3 Kanda Nishikicho,Chiyoda Ku, Tokyo 1018443, Japan
关键词
Internal target volume; 4DCT; Target motion velocity; Time; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; STEREOTACTIC BODY RADIOTHERAPY; GUIDED RADIATION-THERAPY; INSPIRATION BREATH-HOLD; GATED RADIOTHERAPY; LUNG-TUMORS; LINEAR-ACCELERATOR; RESIDUAL MOTION; ARTIFACTS; TRACKING;
D O I
10.1007/s12194-024-00837-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aimed to develop a novel internal target volume (ITV) definition for respiratory motion targets, considering target motion velocity and time. The proposed ITV was evaluated in respiratory-gated radiotherapy. An ITV modified with target motion velocity and time (ITVvt) was defined as an ITV that includes a target motion based on target motion velocity and time. The target motion velocity was calculated using four-dimensional computed tomography (4DCT) images. The ITVvts were created from phantom and clinical 4DCT images. The phantom 4DCT images were acquired using a solid phantom that moved with a sinusoidal waveform (peak-to-peak amplitudes of 10 and 20 mm and cycles of 2-6 s). The clinical 4DCT images were obtained from eight lung cancer cases. In respiratory-gated radiotherapy, the ITVvt was compared with conventional ITVs for beam times of 0.5-2 s within the gating window. The conventional ITV was created by adding a uniform margin as the maximum motion within the gating window. In the phantom images, the maximum volume difference between the ITVvt and conventional ITV was -81.9%. In the clinical images, the maximum volume difference was -53.6%. Shorter respiratory cycles and longer BTs resulted in smaller ITVvt compared with the conventional ITV. Therefore, the proposed ITVvt plan could be used to reduce treatment volumes and doses to normal tissues.
引用
收藏
页码:843 / 853
页数:11
相关论文
共 50 条
  • [1] THE TARGET VOLUME CONCEPT AT THE RECORDING OF EXTERNAL BEAM RADIOTHERAPY
    QUAST, U
    GLAESER, L
    STRAHLENTHERAPIE, 1981, 157 (05) : 317 - 328
  • [2] Variation of clinical target volume definition among Japanese radiation oncologists in external beam radiotherapy for prostate cancer
    Nakamura, Katsumasa
    Shioyama, Yoshiyuki
    Tokumaru, Sunao
    Hayashi, Nobuyuki
    Oya, Natsuo
    Hiraki, Yoshiyuki
    Kusuhara, Kazuo
    Toita, Takafumi
    Suefuji, Hiroaki
    Hayabuchi, Naofumi
    Terashima, Hiromi
    Makino, Masaoki
    Jingu, Kenichi
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2008, 38 (04) : 275 - 280
  • [3] USING RESPIRATORY MOTION TO GUIDE PLANNING TARGET VOLUME MARGINS FOR EXTERNAL BEAM PARTIAL BREAST IRRADIATION
    Kim, Leonard H.
    Goyal, Sharad
    Haffty, Bruce G.
    Taunk, Neil K.
    Yue, Ning J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (04): : 1303 - 1306
  • [4] Investigation of uncertainty in internal target volume definition for lung stereotactic body radiotherapy
    Nakanishi, Daiki
    Oita, Masataka
    Fukunaga, Jun-Ichi
    Hirose, Taka-Aki
    Yoshitake, Tadamasa
    Sasaki, Motoharu
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (04) : 497 - 505
  • [5] Investigation of uncertainty in internal target volume definition for lung stereotactic body radiotherapy
    Daiki Nakanishi
    Masataka Oita
    Jun-Ichi Fukunaga
    Taka-Aki Hirose
    Tadamasa Yoshitake
    Motoharu Sasaki
    Radiological Physics and Technology, 2023, 16 (4) : 497 - 505
  • [6] Imaging Advances for Target Volume Definition in Radiotherapy
    Suarez-Gironzini V.
    Khoo V.
    Current Radiology Reports, 3 (4)
  • [7] Multimodalities imaging for target volume definition in radiotherapy
    Daisne, Jean-Francois
    Gregoire, Vincent
    BULLETIN DU CANCER, 2006, 93 (12) : 1175 - 1182
  • [8] Internal Target Volume Dose Coverage Measurement for Respiratory Tumor Motion
    Jiang, R.
    Gopaul, D.
    Osei, E.
    Barnett, R.
    MEDICAL PHYSICS, 2009, 36 (09) : 4309 - 4309
  • [9] Role of fractionation, type of beam and selection of target volume concepts in external beam radiotherapy
    Mueller, A. -C.
    Hoelscher, T.
    ONKOLOGE, 2015, 21 (09): : 815 - +
  • [10] Target volume definition and organ motion for IMRT
    Nuyttens, J. J.
    EJC SUPPLEMENTS, 2005, 3 (02): : 22 - 22