Reliability of ultrasound real-time tissue elastography in evaluating swallowing-related muscle elasticity and effects of swallowing exercises

被引:0
|
作者
Ota, Tetsuo [1 ]
Madokoro, Sachiko [1 ]
Shimizu, Koshi [2 ,3 ]
Yoneda, Mitsugu [1 ]
机构
[1] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Div Hlth Sci, Kanazawa, Ishikawa, Japan
[3] Keyaki Clin, Dept Rehabil, Kanazawa, Ishikawa, Japan
关键词
muscle elasticity; real-time tissue elastography; reliability; swallowing; swallowing-related muscles; ultrasound; STRAIN RATIO; HARDNESS; STIFFNESS; LESIONS; BENIGN;
D O I
10.1002/sono.12459
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionEvaluating swallowing function, essential for eating, is necessary to detect functional decline, enabling the provision of effective interventions. There is a growing demand for a simple method for evaluating swallowing dynamics. Conventional methods of evaluating swallowing function, such as the fibreoptic endoscopic evaluation of swallowing or videofluoroscopic swallowing study, are highly invasive and require specific equipment only available at certain hospitals, making it difficult for older adults to receive convenient evaluations. Therefore, we used ultrasound real-time tissue elastography (RTE), a low-invasive method, to evaluate tissue elasticity as the strain ratio (SR). This study primarily aimed to verify whether RTE can evaluate the elasticity of swallowing-related muscles (SRMs) and determine intra- and inter-rater reliabilities. The secondary aim was to investigate the effect of swallowing exercises, such as head-lifting exercises, on SRM elasticity.MethodsIntraclass correlation coefficients for SR were calculated using ultrasound B-mode images to determine the reliability of SRM elasticity. SRs before and after the Shaker swallowing exercise were compared using the Wilcoxon signed-rank test.ResultsHigh ICCs for intra- and inter-rater reliabilities were obtained for all targeted SRMs. SR after the Shaker exercise indicated a significant decrease in the geniohyoid muscle and both sides of the digastric muscles, whereas both sides of the masseter exhibited no changes.ConclusionRTE can be used as a novel simple and non-invasive method for assessing and capturing differences in SRs of SRMs after light exercise. Further research may develop a relationship with swallowing function in patients with dysphagia or older individuals.
引用
收藏
页码:60 / 69
页数:10
相关论文
共 50 条
  • [41] Automatic Hyoid Bone Tracking in Real-Time Ultrasound Swallowing Videos Using Deep Learning Based and Correlation Filter Based Trackers
    Feng, Shurui
    Shea, Queenie-Tsung-Kwan
    Ng, Kwok-Yan
    Tang, Cheuk-Ning
    Kwong, Elaine
    Zheng, Yongping
    SENSORS, 2021, 21 (11)
  • [42] Reliability of Real-Time Ultrasound to Detect Pelvic Floor Muscle Contraction in Urinary Incontinent Women
    Yang, Jenn-Ming
    Yang, Shwu-Huey
    Yang, Shu-Yu
    Yang, Evelyn
    Huang, Wen-Chen
    JOURNAL OF UROLOGY, 2009, 182 (05): : 2392 - 2396
  • [43] EXAMINATION OF PELVIC FLOOR MUSCLES HARDNESS IN PATIENTS WITH INTERSTITIAL CYSTITIS USING ULTRASOUND REAL-TIME TISSUE ELASTOGRAPHY
    Takahashi, Y.
    Kitta, T.
    Ouchi, M.
    Chiba, H.
    Higuchi, M.
    Togo, M.
    Shinohara, N.
    NEUROUROLOGY AND URODYNAMICS, 2020, 39 : S406 - S407
  • [44] Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration
    Gilbert, Fabian
    Klein, Detlef
    Weng, Andreas Max
    Koestler, Herbert
    Schmitz, Benedikt
    Schmalzl, Jonas
    Boehm, Dirk
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [45] Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration
    Fabian Gilbert
    Detlef Klein
    Andreas Max Weng
    Herbert Köstler
    Benedikt Schmitz
    Jonas Schmalzl
    Dirk Böhm
    BMC Musculoskeletal Disorders, 18
  • [46] Real-time ultrasound elastography in 180 axillary lymph nodes: elasticity distribution in healthy lymph nodes and prediction of breast cancer metastases
    Wojcinski, Sebastian
    Dupont, Jennifer
    Schmidt, Werner
    Cassel, Michael
    Hillemanns, Peter
    BMC MEDICAL IMAGING, 2012, 12
  • [47] Reliability of real-time ultrasound for measuring skeletal muscle size in human limbs in vivo: a systematic review
    English, Coralie
    Fisher, Laura
    Thoirs, Kerry
    CLINICAL REHABILITATION, 2012, 26 (10) : 934 - 944
  • [48] Real-time ultrasound elastography in 180 axillary lymph nodes: elasticity distribution in healthy lymph nodes and prediction of breast cancer metastases
    Sebastian Wojcinski
    Jennifer Dupont
    Werner Schmidt
    Michael Cassel
    Peter Hillemanns
    BMC Medical Imaging, 12
  • [49] Diagnostic performance of conventional ultrasound and quantitative and qualitative real-time shear wave elastography in musculoskeletal soft tissue tumors
    Ao Li
    Xiao-Jing Peng
    Qian Ma
    Ye Dong
    Cui-Lian Mao
    Yu Hu
    Journal of Orthopaedic Surgery and Research, 15
  • [50] Diagnostic performance of conventional ultrasound and quantitative and qualitative real-time shear wave elastography in musculoskeletal soft tissue tumors
    Li, Ao
    Peng, Xiao-Jing
    Ma, Qian
    Dong, Ye
    Mao, Cui-Lian
    Hu, Yu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)