An experimental validation of a filtering approach for prompt gamma prediction in a research proton treatment planning system

被引:0
|
作者
Huang, Ze [1 ]
Tian, Liheng [1 ]
Janssens, Guillaume [2 ]
Smeets, Julien [2 ]
Xie, Yunhe [3 ]
Teo, Boon-Keng Kevin [4 ]
Nilsson, Rasmus [5 ]
Traneus, Erik [5 ]
Parodi, Katia [1 ]
Pinto, Marco [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Med Phys, Munich, Germany
[2] Ion Beam Applicat SA, Louvain la Neuve, Belgium
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA USA
[4] Univ Penn, Dept Radiat Oncol, Philadelphia, PA USA
[5] RaySearch Labs AB, Stockholm, Sweden
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 15期
关键词
prompt gamma range verification; proton therapy; REGGUI; RayStation; filtering approach PG prediction; BEAM RANGE VERIFICATION; MONTE-CARLO; SLIT-CAMERA; PET VERIFICATION; RAY EMISSION; THERAPY; DISTRIBUTIONS; SENSITIVITY; RADIATION; FEASIBILITY;
D O I
10.1088/1361-6560/ad6116
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Prompt gamma (PG) radiation generated from nuclear reactions between protons and tissue nuclei can be employed for range verification in proton therapy. A typical clinical workflow for PG range verification compares the detected PG profile with a predicted one. Recently, a novel analytical PG prediction algorithm based on the so-called filtering formalism has been proposed and implemented in a research version of RayStation (RaySearch Laboratories AB), which is a widely adopted treatment planning system. This work validates the performance of the filtering PG prediction approach. Approach. The said algorithm is validated against experimental data and benchmarked with another well-established PG prediction algorithm implemented in a MATLAB-based software REGGUI. Furthermore, a new workflow based on several PG profile quality criteria and analytical methods is proposed for data selection. The workflow also calculates sensitivity and specificity information, which can help practitioners to decide on irradiation course interruption during treatment and monitor spot selection at the treatment planning stage. With the proposed workflow, the comparison can be performed on a limited number of selected high-quality irradiation spots without neighbouring-spot aggregation. Main results. The mean shifts between the experimental data and the predicted PG detection (PGD) profiles (Delta PGD) by the two algorithms are estimated to be 1.5 +/- 2.1 mm and -0.6 +/- 2.2 mm for the filtering and REGGUI prediction methods, respectively. The Delta PGD difference between two algorithms is observed to be consistent with the beam model difference within uncertainty. However, the filtering approach requires a much shorter computation time compared to the REGGUI approach. Significance. The novel filtering approach is successfully validated against experimental data and another widely used PG prediction algorithm. The workflow designed in this work selects spots with high-quality PGD shift calculation results, and performs sensitivity and specificity analyses to assist clinical decisions.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Prompt Gamma-Ray Spectroscopy Validation for Real-Time Proton Range Verification
    Tattenberg, S.
    Marants, R.
    Niepel, K.
    Bortfeld, T.
    Sudhyadhom, A.
    Landry, G.
    Parodi, K.
    Verburg, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E534 - E535
  • [22] Experimental Study of Discrete Prompt Gamma Lines for In-Vivo Proton Range Verification
    Verburg, J.
    Riley, K.
    Seco, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [23] Simulation and experimental verification of prompt gamma-ray emissions during proton irradiation
    Schumann, A.
    Petzoldt, J.
    Dendooven, P.
    Enghardt, W.
    Golnik, C.
    Hueso-Gonzalez, F.
    Kormoll, T.
    Pausch, G.
    Roemer, K.
    Fiedler, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (10): : 4197 - 4207
  • [24] EXPERIMENTAL VERIFICATION OF KEY CROSS SECTIONS FOR PROMPT-GAMMA IMAGING IN PROTON THERAPY
    Wronska, A.
    Ahmed, A. Anees
    Andres, A.
    Bednarczyk, P.
    Besuglow, J.
    Gazdowicz, G.
    Herweg, K.
    Hetzel, R.
    Kasper, J.
    Kelleter, L.
    Konefal, A.
    Kulessa, P.
    Laihem, K.
    Leidner, J.
    Magiera, A.
    Rusiecka, K.
    Stachura, D.
    Stahl, A.
    Zieblinski, M.
    ACTA PHYSICA POLONICA B, 2017, 48 (10): : 1631 - 1637
  • [25] FoCa: a modular treatment planning system for proton radiotherapy with research and educational purposes
    Sanchez-Parcerisa, D.
    Kondrla, M.
    Shaindlin, A.
    Carabe, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23): : 7341 - 7360
  • [26] SYSTEM APPROACH TO RESEARCH PLANNING
    MCHEDLISHVILY, GI
    VESTNIK AKADEMII NAUK SSSR, 1977, (05) : 89 - 93
  • [27] A Fast Analytical Approach for Prompt Gamma and PET Predictions in a TPS for Proton Range Verification
    Kroniger, K.
    Herzog, M.
    Landry, G.
    Traneus, E.
    Dedes, G.
    Parodi, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3199 - 3199
  • [28] Implementation of an analytical solution to lateral dose prediction in a proton therapy treatment planning system
    Bellinzona, E. V.
    Landry, G.
    Fontana, A.
    Embriaco, A.
    Resch, A.
    Ciocca, M.
    Ferrari, A.
    Kamp, F.
    Mairani, A.
    Sala, P.
    Tessonnier, T.
    Wilkens, J.
    Rotondi, A.
    Parodi, K.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S8 - S9
  • [29] Experimental validation of a thermophysical fluid model for use in a hyperthermia treatment planning system
    Schooneveldt, Gerben
    Loke, Daan R.
    Zweije, Remko
    Helderman, Roxan F. C. P. A.
    Kok, H. Petra
    Crezee, Hans
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 152 (152)
  • [30] Microdosimetric approach for treatment planning in proton therapy
    Pisciotta, P.
    Magini, J.
    Traneus, E.
    Hussein, M.
    Both, S.
    Schettino, G.
    Romano, F.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1735 - S1737