An experimental validation of a filtering approach for prompt gamma prediction in a research proton treatment planning system

被引:0
|
作者
Huang, Ze [1 ]
Tian, Liheng [1 ]
Janssens, Guillaume [2 ]
Smeets, Julien [2 ]
Xie, Yunhe [3 ]
Teo, Boon-Keng Kevin [4 ]
Nilsson, Rasmus [5 ]
Traneus, Erik [5 ]
Parodi, Katia [1 ]
Pinto, Marco [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Med Phys, Munich, Germany
[2] Ion Beam Applicat SA, Louvain la Neuve, Belgium
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA USA
[4] Univ Penn, Dept Radiat Oncol, Philadelphia, PA USA
[5] RaySearch Labs AB, Stockholm, Sweden
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 15期
关键词
prompt gamma range verification; proton therapy; REGGUI; RayStation; filtering approach PG prediction; BEAM RANGE VERIFICATION; MONTE-CARLO; SLIT-CAMERA; PET VERIFICATION; RAY EMISSION; THERAPY; DISTRIBUTIONS; SENSITIVITY; RADIATION; FEASIBILITY;
D O I
10.1088/1361-6560/ad6116
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Prompt gamma (PG) radiation generated from nuclear reactions between protons and tissue nuclei can be employed for range verification in proton therapy. A typical clinical workflow for PG range verification compares the detected PG profile with a predicted one. Recently, a novel analytical PG prediction algorithm based on the so-called filtering formalism has been proposed and implemented in a research version of RayStation (RaySearch Laboratories AB), which is a widely adopted treatment planning system. This work validates the performance of the filtering PG prediction approach. Approach. The said algorithm is validated against experimental data and benchmarked with another well-established PG prediction algorithm implemented in a MATLAB-based software REGGUI. Furthermore, a new workflow based on several PG profile quality criteria and analytical methods is proposed for data selection. The workflow also calculates sensitivity and specificity information, which can help practitioners to decide on irradiation course interruption during treatment and monitor spot selection at the treatment planning stage. With the proposed workflow, the comparison can be performed on a limited number of selected high-quality irradiation spots without neighbouring-spot aggregation. Main results. The mean shifts between the experimental data and the predicted PG detection (PGD) profiles (Delta PGD) by the two algorithms are estimated to be 1.5 +/- 2.1 mm and -0.6 +/- 2.2 mm for the filtering and REGGUI prediction methods, respectively. The Delta PGD difference between two algorithms is observed to be consistent with the beam model difference within uncertainty. However, the filtering approach requires a much shorter computation time compared to the REGGUI approach. Significance. The novel filtering approach is successfully validated against experimental data and another widely used PG prediction algorithm. The workflow designed in this work selects spots with high-quality PGD shift calculation results, and performs sensitivity and specificity analyses to assist clinical decisions.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] A Filtering Approach for PET and PG Predictions in a Proton Treatment Planning System
    Pinto, M.
    Kroeniger, K.
    Bauer, J.
    Nilsson, R.
    Traneus, E.
    Parodi, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E446 - E446
  • [2] A filtering approach for PET and PG predictions in a proton treatment planning system
    Pinto, M.
    Kroeniger, K.
    Bauer, J.
    Nilsson, R.
    Traneus, E.
    Parodi, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (09):
  • [3] Accounting for prompt gamma emission and detection for range verification in proton therapy treatment planning
    Tian, Liheng
    Huang, Ze
    Janssens, Guillaume
    Landry, Guillaume
    Dedes, George
    Kamp, Florian
    Belka, Claus
    Pinto, Marco
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):
  • [4] Experimental Validation of An Analytical Model for Prompt Gamma Imaging
    Sterpin, E.
    Janssens, G.
    Smeets, J.
    Vander Stappen, F.
    Priegnitz, M.
    Perali, I.
    Prieels, D.
    Vynckier, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3726 - 3726
  • [5] Experimental validation of the filtering approach for dose monitoring in proton therapy at low energy
    Attanasi, F.
    Belcari, N.
    Camarda, M.
    Del Guerra, A.
    Moehrs, S.
    Rosso, V.
    Vecchio, S.
    Lanconelli, N.
    Cirrone, G. A. P.
    Di Rosa, F.
    Russo, G.
    PHYSICA MEDICA, 2008, 24 (02) : 102 - 106
  • [6] Validation of the RayOcular Treatment Planning System for Proton Therapy of the Eye
    Koska, B.
    Wulff, J.
    Baecker, C.
    Baeumer, C.
    Behrends, C.
    Timmermann, B.
    MEDICAL PHYSICS, 2022, 49 (06) : E212 - E212
  • [7] Verifying Proton Treatment Delivery Using Prompt Gamma Imaging
    Polf, J. C.
    Beddar, S.
    Mackin, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S923 - S924
  • [8] A new treatment planning approach accounting for prompt gamma range verification and interfractional anatomical changes
    Tian, Liheng
    Landry, Guillaume
    Dedes, George
    Pinto, Marco
    Kamp, Florian
    Belka, Claus
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (09):
  • [9] EXPERIMENTAL MEASUREMENTS OF PROTON-INDUCED PROMPT SECONDARY GAMMA RAYS
    HAFFNER, JW
    BEEVER, ER
    RUSLING, DH
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, 10 (02): : 425 - &
  • [10] Patient-Specific Collision Prediction Software Integrated with the Treatment Planning System: Design and Experimental Validation
    Sanchez-Rodriguez, J.
    Liu, T.
    Shim, H.
    Schreibmann, E.
    MEDICAL PHYSICS, 2018, 45 (06) : E378 - E378