Digital Image Correlation Validation of Finite Element Strain Analysis of Dental Implant Insertion for Two Implant Designs

被引:0
|
作者
Yang, Baixuan [1 ]
Irastorza-Landa, Ainara [2 ]
Heuberger, Peter [2 ]
Ploeg, Heidi-Lynn [1 ]
机构
[1] Queens Univ, Kingston, ON, Canada
[2] Nobel Biocare Serv AG, Kloten, Switzerland
基金
加拿大自然科学与工程研究理事会;
关键词
Dental Implant; FEA; DIC; Insertion; SUPPORTED PROSTHESES; LOAD-TRANSFER; BONE; SHRINKAGE; CEMENT;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Sufficient anchorage of dental implants, defined as mechanical engagement between implant and bone at the time of insertion, has been recommended for positive clinical outcomes, particularly in immediate loading protocols. Accurate measuring and analysis of stress and strain in the bone are imperative to understand anchorage from the biomechanics perspective. However, the stress and strain distributions at the bone-implant interface are impossible to measure in vivo. Therefore, the aim of this study was to develop and validate an explicit continuum finite element analysis (FEA) to investigate the stress and strain in a bone surrogate during the insertion of a dental implant: with cutting flute (CF) and without (NCF). Ten dental implants (five with CF and five with NCF) were inserted into ten rigid polyurethane (PU) foam blocks with a prepared pilot hole. During the insertion, a stereo digital image correlation (DIC) system was used to record in-plane deformation on the PU foam surface at a frequency of 1.0 Hz; and, surface von Mises strain, epsilon(v_DIC), was calculated (VIC-3D, Correlated Solutions Inc). In parallel, the insertion was simulated using FEA with explicit solver (Abaqus Explicit version 2017, Simulia). The PU foam was defined as an elastic-plastic material with a progressive crushable foam failure behaviour. The surface von Mises strain predicted from FEA, epsilon(v_FEA), was compared against epsilon(v_DIC). Uncertainty of DIC displacement measurement was 0.6 mu m; and the static noise floor for the strain measurement was 500 microstrain (mu epsilon). Coefficient of determination for epsilon(v_DIC) and epsilon(v_FEA) along a horizontal line for the CF and NCF implants were 0.80 and 0.78, respectively, which suggested the overall FEA performance was good. FEA results indicated that the cutting flute reduced the maximum shear stress in the PU foam and axial force which facilitated the insertion with less effort. This study demonstrated the successful combination of mechanical testing and FEA to better understand the mechanics of dental implant insertion.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Finite Element Analysis of Stress in Dental Bridge with Implant
    Huang, Wan-Ting
    Cheng, Han-Yi
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2020, 10 (06) : 743 - 748
  • [12] Finite element analysis of dental implant surgical guides
    Arora, Varun
    Kumar, Sanjeev
    Kalra, Parveen
    Goyal, Aneesh
    MATERIALS TODAY-PROCEEDINGS, 2022, 56 : 3137 - 3141
  • [13] Step-wise analysis of the dental implant insertion process using the finite element technique
    van Staden, Rudi C.
    Guan, Hong
    Johnson, Newell W.
    Loo, Yew-Chaye
    Meredith, Neil
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (03) : 303 - 313
  • [14] Comparison of implant body designs and threaded designs of dental implants: A 3-dimensional finite element analysis
    Huang, Heng-Li
    Chang, Chin-Han
    Hsu, Jui-Ting
    Fallgatter, Alison M.
    Ko, Ching-Chang
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (04) : 551 - 562
  • [15] Effects of Implant Diameter, Insertion Depth, and Loading Angle on Stress/Strain Fields in Implant/Jawbone Systems: Finite Element Analysis
    Qian, Lihe
    Todo, Mitsugu
    Matsushita, Yasuyuki
    Koyano, Kiyoshi
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 877 - 886
  • [16] New Subperiosteal Dental Implant Design with Finite Element Analysis and Mechanical Validation: A Design Validation Study
    Vanaclocha, Vicente
    Atienza, Carlos
    Vanaclocha, Amparo
    Penuelas, Andres
    Gomez-Herrero, Juan
    Perez-Carrio, Francisco
    Diego-Leyda, Jose Antonio
    Saiz-Sapena, Nieves
    Vanaclocha, Leyre
    MATERIALS, 2025, 18 (03)
  • [17] Finite element analysis of loading on the external hexagon of dental implant
    Reis, TCA
    Elias, CN
    Gouvéia, JP
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1063 - 1063
  • [18] Finite-Element Analysis of Stress on Dental Implant Prosthesis
    Rubo, Jose Henrique
    Capello Souza, Edson Antonio
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2010, 12 (02) : 105 - 113
  • [19] Comparison of three implant systems under preload loss: A finite element analysis validated by digital image correlation methods
    Anniwaer, Annikaer
    Yin, Zhengrong
    Zhu, Jiakang
    Jin, Chunxiao
    Muhetaer, Aihemaiti
    Huang, Cui
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024,
  • [20] Dynamic modelling and simulation of dental implant insertion process-A finite element study
    Guan, Hong
    van Staden, Rudi C.
    Johnson, Newell W.
    Loo, Yew-Chaye
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2011, 47 (08) : 886 - 897