Transcatheter Patent Ductus Arteriosus Closure in Premature Infants: Comparison of Echocardiogram and Angiogram Measurements

被引:1
|
作者
Nijres, Bassel Mohammad [1 ]
Khallaf, Mohamed [1 ]
Bischoff, Adrianne Rahde [2 ]
Carr, Kaitlin [1 ]
Gupta, Umang [1 ]
Mcnamara, Patrick J. [2 ]
Windsor, Jimmy [3 ]
Aldoss, Osamah [1 ]
机构
[1] Univ Iowa, Stead Family Childrens Hosp, Div Pediat Cardiol, BT 1021,200 Hawkins Dr, Iowa City, IA 52242 USA
[2] Univ Iowa, Stead Family Childrens Hosp, Div Neonatol, Iowa City, IA USA
[3] Univ Iowa, Div Pediat Anesthesia, Stead Family Childrens Hosp, Iowa City, IA USA
关键词
Premature infants; PDA closure; PDA dimensions; CATHETER CLOSURE; ACCESS;
D O I
10.1007/s00246-024-03620-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter patent ductus arteriosus (PDA) closure (TCPC) utilizing transthoracic echocardiogram (TTE) as the sole imaging guide could simplify care. This single-center study compares PDA dimensions obtained from the TTE and angiogram images of patients who underwent attempted TCPC at Stead Family Children's Hospital from 10/01/2019 to 10/31/2020. Blinded investigators measured these dimensions solely for this study and had no impact on clinical care. Also, a hypothetical Piccolo device size was chosen based on the TTE dimensions and another on the angiographic dimensions, and then the correlation was analyzed. Sixty-two patients underwent TCPC attempts. TTE tends to overestimate the PDA narrowest dimension and underestimate the PDA length and aortic end dimension. Linear regression analysis revealed a weak correlation between the length and aortic diameter (R = 0.37 and 0.21, respectively). A modest correlation was observed for the smallest dimension without color Doppler (R = 0.57) and with color Doppler, which was utilized when needed (R = 0.6). Bland-Altman analysis revealed a smaller mean difference between the TTE and angiogram measurements of the narrowest diameter without color Doppler (0.4 mm) and with color Doppler (used as needed) (0.4 mm). However, the mean difference is larger for the aortic end (- 1.64 mm) and the length (- 1.73 mm). TTE accurately predicted the Piccolo device size in 43 (72%) patients and overestimated the size in 17 (28%) patients to the next size. Our findings should be verified with further studies, and additional development of protocols is needed to use TTE to guide TCPC without fluoroscopy.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] SURGICAL CLOSURE OF PATENT DUCTUS-ARTERIOSUS IN PREMATURE-INFANTS
    RITTENHOUSE, EA
    DOTY, DB
    LAUER, RM
    EHRENHAFT, JL
    AMERICAN JOURNAL OF CARDIOLOGY, 1975, 35 (01): : 165 - 165
  • [22] Transcatheter closure of residual patent ductus arteriosus
    El-Saiedi, Sonia Ali
    Elshedoudy, Sahar Abdulla
    El-Sisi, Ammal Mahmoud
    Hanna, Baher Matta
    Fattouh, Aya Mohammed
    Hijazi, Ziyad
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (01) : 78 - 82
  • [23] Transcatheter Device Closure of Patent Ductus Arteriosus
    Sultan, Mehboob
    Ullah, Maad
    Sadiq, Nadeem
    Akhtar, Khurram
    Akbar, Hajira
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2014, 24 (10): : 710 - 713
  • [24] Radiation and Contrast Exposure During Transcatheter Patent Ductus Arteriosus in Premature Infants
    Khallaf, Mohamed
    Aldoss, Osamah
    Carr, Kaitlin
    Nijres, Bassel
    PEDIATRIC CARDIOLOGY, 2022, 43 (08) : 1982 - 1982
  • [25] RADIATION EXPOSURE FROM TRANSCATHETER PATENT DUCTUS ARTERIOSUS CLOSURE IN PREMATURE INFANTS LESS THAN 2.5 KG
    Johnson, Jason
    Rose, Daniel I. R.
    Brint, Monica
    Tailor, Neil
    Philip, Ranjit
    Sathanandam, Shyam
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1380 - 1380
  • [26] Comparison of transcatheter patent ductus arteriosus closure between children and adults
    Yasuhara, Jun
    Kuno, Toshiki
    Kumamoto, Takashi
    Kojima, Takuro
    Shimizu, Hiroyuki
    Yoshiba, Shigeki
    Kobayashi, Toshiki
    Sumitomo, Naokata
    HEART AND VESSELS, 2020, 35 (11) : 1605 - 1613
  • [27] Renal Function After Transcatheter Piccolo Patent Ductus Arteriosus Closure With Contrast Angiography in Extremely Premature Infants
    Herron, Christopher
    Forbes, Thomas J.
    Kobayashi, Daisuke
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 181 : 113 - 117
  • [28] Transcatheter closure of very large patent ductus arteriosus with the modified patent ductus arteriosus closure device.
    Zhang, F.
    Ge, J.
    Zhou, D.
    Guan, L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (8B): : 50D - 50D
  • [29] Transcatheter closure of patent ductus arteriosus in infants using the Amplatzer duct occluder
    Fischer, G
    Kramer, HH
    Uebing, A
    Renaud, C
    Grabitz, R
    EUROPEAN HEART JOURNAL, 2001, 22 : 418 - 418
  • [30] Comparison of transcatheter patent ductus arteriosus closure between children and adults
    Jun Yasuhara
    Toshiki Kuno
    Takashi Kumamoto
    Takuro Kojima
    Hiroyuki Shimizu
    Shigeki Yoshiba
    Toshiki Kobayashi
    Naokata Sumitomo
    Heart and Vessels, 2020, 35 : 1605 - 1613