PERFORMANCE OF FLAT-TUBE LOUVERED-FIN AUTOMOTIVE EVAPORATOR WITH R1234yf

被引:0
|
作者
Gurudatt, H. M. [1 ]
Narasimham, G. S. V. L. [1 ]
Gowda, B. Sadashive [2 ]
机构
[1] Indian Inst Sci, Bangalore, Karnataka, India
[2] Vidyavardhaka Coll Engn, Mysore, Karnataka, India
来源
PROCEEDINGS OF ASME 2022 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2022, VOL 8 | 2022年
关键词
Automobile Air Conditioning; Evaporator; Louvered-fin; Numerical simulation; R1234yf; AIR-CONDITIONING SYSTEM; HEAT-TRANSFER; HFO-1234YF; SIMULATION;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Following the Kyoto Protocol and the more recent Kigali agreement, Hydrofluoroolefins (HFOs) are considered as the low global warming drop-in or substitute refrigerants for hydrofluorocarbons (HFCs) which have high global warming potential. The HFO R1234yf gained significant importance as a replacement for R134a in automobile air conditioning. In this context, the performance of a two- slab automotive evaporator with R1234yf numerical simulation is reported in this paper. The simulation is conducted by considering the heat transfer from air to the outside wetted surface consisting of louvered fins and tube wall, from there to the inside tube wall, and from there to the bulk of the boiling refrigerant inside the tube. The combined effect of heat and mass transfer from air to the wetted surface is described by the enthalpy potential method. For the two-phase and superheating regions suitable heat transfer correlations are employed. The results show that the refrigerant side heat transfer coefficient increases with increase in vapour quality up to around 80% and then decreases with further increase in the vapour quality. The major contribution to the cooling capacity is the latent heat abstraction during the flow boiling process occurring inside the tube. The temperatures of the condensate water film surface and the inner and outer tube wall surfaces are nearer to the bulk temperature of the refrigerant because of the high heat transfer coefficient on the refrigerant side. Results are also presented for the refrigerant side pressure drop and the evaporator exit air temperature and humidity ratio.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Comparative Investigation on the Thermophysical Property and System Performance of R1234yf
    Li, Gailian
    Jin, Tingxiang
    Xu, Ran
    Lv, Zijian
    ENERGIES, 2023, 16 (13)
  • [22] PERFORMANCE OF R1234yf AND R513A AS ALTERNATIVES TO R134a IN AUTOMOTIVE AIR CONDITIONING SYSTEMS IN WINTER
    Meng, Zhaofeng
    Cui, Xiangna
    Liu, Yin
    Wang, Shun
    DU, Chenyang
    Hu, Rusheng
    THERMAL SCIENCE, 2023, 27 (3A): : 1937 - 1946
  • [23] Experimental study of the heat transfer of supercritical R1234yf as a substitute for R134a in a horizontal micro-fin tube
    Wang, Dabiao
    Fang, Junhui
    Li, Lanlan
    Feng, Ruijie
    Dai, Xiaoye
    Shi, Lin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 144 : 1 - 13
  • [24] Performance Analysis of R1234yf and R134a in a Multi-Evaporator with Individual Expansion Valve in a Single Compression System
    Riyami H.A.
    Solomon G.R.
    Ravikumar T.S.
    Balaji D.
    Hariram V.
    International Journal of Vehicle Structures and Systems, 2023, 15 (04) : 534 - 539
  • [25] Experimental Evaluation of an Automotive Heat Pump System with R1234yf as an Alternative to R134a
    Direk, Mehmet
    Yuksel, Fikret
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (02) : 719 - 728
  • [26] Experimental Evaluation of an Automotive Heat Pump System with R1234yf as an Alternative to R134a
    Mehmet Direk
    Fikret Yüksel
    Arabian Journal for Science and Engineering, 2020, 45 : 719 - 728
  • [27] R1234yf condensation inside a 3.4 mm ID horizontal microfin tube
    Diani, Andrea
    Cavallini, Alberto
    Rossetto, Luisa
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 75 : 178 - 189
  • [28] Nucleate boiling heat transfer coefficients of R1234yf on plain and low fin surfaces
    Park, Ki-Jung
    Jung, Dongsoo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (03): : 553 - 557
  • [29] PERFORMANCE COMPARISON OF VARIOUS COOLANTS FOR LOUVERED FIN TUBE AUTOMOTIVE RADIATOR
    Sahoo, Rashmi Rekha
    Ghosh, Pradyumna
    Sarkar, Jahar
    THERMAL SCIENCE, 2017, 21 (06): : 2871 - 2881
  • [30] Exergy analysis of R1234yf and R1234ze as R134a replacements in a two evaporator vapour compression refrigeration system
    Yataganbaba, Alptug
    Kilicarslan, Ali
    Kurtbas, Irfan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2015, 60 : 26 - 37