Patient-specific quality assurance of dynamically-collimated proton therapy treatment plans

被引:0
|
作者
Bennett, Laura C. [1 ]
Hyer, Daniel E. [2 ]
Vu, Justin [1 ]
Patwardhan, Kaustubh [2 ]
Erhart, Kevin [3 ]
Gutierrez, Alonso N. [4 ]
Pons, Eduardo [4 ]
Jensen, Eric [5 ]
Ubau, Manual [5 ]
Zapata, Julio [5 ]
Wroe, Andrew [4 ]
Wake, Karsten [6 ]
Nelson, Nicholas P. [6 ,7 ]
Culberson, Wesley S. [6 ]
Smith, Blake R. [2 ]
Hill, Patrick M. [8 ]
Flynn, Ryan T. [2 ]
机构
[1] Univ Iowa, Seamans Ctr Engn Arts & Sci 5601, Roy J Carver Dept Biomed Engn, Iowa City, IA USA
[2] Univ Iowa Hosp & Clin, Dept Radiat Oncol, Iowa City, IA USA
[3] Decimal LLC, Sanford, FL USA
[4] Baptist Hlth South Florida, Miami Canc Inst, Dept Radiat Oncol, Miami, FL USA
[5] Ion Beam Applicat SA, R&D Proton Therapy, Louvain La Neuve, Belgium
[6] Univ Wisconsin, Sch Med & Publ Hlth, Dept Med Phys, Madison, WI USA
[7] Univ Utah, Huntsman Canc Inst, Dept Radiat Oncol, Salt Lake City, UT USA
[8] Univ Wisconsin, Sch Med & Publ Hlth, Dept Human Oncol, Madison, WI USA
基金
美国国家卫生研究院;
关键词
collimation; dose calculation; dynamic collimation system (DCS); dynamic collimation; pencil beam scanning (PBS); proton therapy; spot scanning; SPOT SIZE; CONFORMITY;
D O I
10.1002/mp.17295
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe dynamic collimation system (DCS) provides energy layer-specific collimation for pencil beam scanning (PBS) proton therapy using two pairs of orthogonal nickel trimmer blades. While excellent measurement-to-calculation agreement has been demonstrated for simple cube-shaped DCS-trimmed dose distributions, no comparison of measurement and dose calculation has been made for patient-specific treatment plans.PurposeTo validate a patient-specific quality assurance (PSQA) process for DCS-trimmed PBS treatment plans and evaluate the agreement between measured and calculated dose distributions.MethodsThree intracranial patient cases were considered. Standard uncollimated PBS and DCS-collimated treatment plans were generated for each patient using the Astroid treatment planning system (TPS). Plans were recalculated in a water phantom and delivered at the Miami Cancer Institute (MCI) using an Ion Beam Applications (IBA) dedicated nozzle system and prototype DCS. Planar dose measurements were acquired at two depths within low-gradient regions of the target volume using an IBA MatriXX ion chamber array.ResultsMeasured and calculated dose distributions were compared using 2D gamma analysis with 3%/3 mm criteria and low dose threshold of 10% of the maximum dose. Median gamma pass rates across all plans and measurement depths were 99.0% (PBS) and 98.3% (DCS), with a minimum gamma pass rate of 88.5% (PBS) and 91.2% (DCS).ConclusionsThe PSQA process has been validated and experimentally verified for DCS-collimated PBS. Dosimetric agreement between the measured and calculated doses was demonstrated to be similar for DCS-collimated PBS to that achievable with noncollimated PBS.
引用
收藏
页码:5901 / 5910
页数:10
相关论文
共 50 条
  • [21] The Impact of Dose Calibration Point Differences Between the Treatment Plan and Patient-specific Quality Assurance in Passive Scattering Proton Beam Therapy
    Mori, Yutaro
    Isobe, Tomonori
    Takei, Hideyuki
    Kamizawa, Satoshi
    Tomita, Tetsuya
    Kobayashi, Daisuke
    Sakurai, Hideyuki
    Sakae, Takeji
    IN VIVO, 2024, 38 (05): : 2478 - 2483
  • [22] Machine learning and lean six sigma for targeted patient-specific quality assurance of volumetric modulated arc therapy plans
    Lambri, Nicola
    Dei, Damiano
    Goretti, Giulia
    Crespi, Leonardo
    Brioso, Ricardo Coimbra
    Pelizzoli, Marco
    Parabicoli, Sara
    Bresolin, Andrea
    Gallo, Pasqualina
    La Fauci, Francesco
    Lobefalo, Francesca
    Paganini, Lucia
    Reggiori, Giacomo
    Loiacono, Daniele
    Franzese, Ciro
    Tomatis, Stefano
    Scorsetti, Marta
    Mancosu, Pietro
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [23] Automation of routine elements for spot-scanning proton patient-specific quality assurance
    Morales, Danairis Hernandez
    Shan, Jie
    Liu, Wei
    Augustine, Kurt E.
    Bues, Martin
    Davis, Michael J.
    Fatyga, Mirek
    Johnson, Jedediah E.
    Mundy, Daniel W.
    Shen, Jiajian
    Younkin, James E.
    Stoker, Joshua B.
    MEDICAL PHYSICS, 2019, 46 (01) : 5 - 14
  • [24] Quality assurance-based optimization (QAO): Towards improving patient-specific quality assurance in volumetric modulated arc therapy plans using machine learning
    Wall, Phillip D. H.
    Fontenot, Jonas D.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 87 : 136 - 143
  • [25] Quality assurance of micro-MLC based IMRT plans using patient-specific phantom
    Sunel, S.
    Yeginer, M.
    Akyol, F.
    Biltekin, F.
    Ozyigit, G.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S918 - S918
  • [26] Evaluation of Range Robustness for a Dynamically Collimated Proton Therapy Treatment Plan
    Bennett, L.
    Hyer, D.
    Erhart, K.
    Smith, B.
    Nelson, N.
    Geoghegan, T.
    Hill, P.
    Flynn, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E773 - E773
  • [27] Analysis of dose comparison techniques for patient-specific quality assurance in radiation therapy
    Yu, Liting
    Tang, Timothy L. S.
    Cassim, Naasiha
    Livingstone, Alexander
    Cassidy, Darren
    Kairn, Tanya
    Crowe, Scott B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (11): : 189 - 198
  • [28] A Systematic Approach to Patient-Specific Quality Assurance for Volumetric Modulated Arc Therapy
    SONG Yu-lin
    Ceferino Obcemea
    Boris Mueller
    Borys Mychalczak
    ChineseJournalofBiomedicalEngineering, 2015, 24 (02) : 58 - 65
  • [29] Transitioning from measurement-based to combined patient-specific quality assurance for intensity-modulated proton therapy
    Chen, Mei
    Yepes, Pablo
    Hojo, Yoshifumi
    Poenisch, Falk
    Li, Yupeng
    Chen, Jiayi
    Xu, Cheng
    He, Xiaodong
    Gunn, G. Brandon
    Frank, Steven J.
    Sahoo, Narayan
    Li, Heng
    Zhu, Xiaorong Ronald
    Zhang, Xiaodong
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1107):
  • [30] Development of a three-dimensional scintillation detector for pencil beam verification in proton therapy patient-specific quality assurance
    Frelin, Anne-Marie
    Daviau, Gautier
    Bui, My Hoang Hoa
    Fontbonne, Cathy
    Fontbonne, Jean-Marc
    Lebhertz, Dorothee
    Mainguy, Erwan
    Moignier, Cyril
    Thariat, Juliette
    Vela, Anthony
    MEDICAL PHYSICS, 2024,