Patient-specific quality assurance of dynamically-collimated proton therapy treatment plans

被引:0
|
作者
Bennett, Laura C. [1 ]
Hyer, Daniel E. [2 ]
Vu, Justin [1 ]
Patwardhan, Kaustubh [2 ]
Erhart, Kevin [3 ]
Gutierrez, Alonso N. [4 ]
Pons, Eduardo [4 ]
Jensen, Eric [5 ]
Ubau, Manual [5 ]
Zapata, Julio [5 ]
Wroe, Andrew [4 ]
Wake, Karsten [6 ]
Nelson, Nicholas P. [6 ,7 ]
Culberson, Wesley S. [6 ]
Smith, Blake R. [2 ]
Hill, Patrick M. [8 ]
Flynn, Ryan T. [2 ]
机构
[1] Univ Iowa, Seamans Ctr Engn Arts & Sci 5601, Roy J Carver Dept Biomed Engn, Iowa City, IA USA
[2] Univ Iowa Hosp & Clin, Dept Radiat Oncol, Iowa City, IA USA
[3] Decimal LLC, Sanford, FL USA
[4] Baptist Hlth South Florida, Miami Canc Inst, Dept Radiat Oncol, Miami, FL USA
[5] Ion Beam Applicat SA, R&D Proton Therapy, Louvain La Neuve, Belgium
[6] Univ Wisconsin, Sch Med & Publ Hlth, Dept Med Phys, Madison, WI USA
[7] Univ Utah, Huntsman Canc Inst, Dept Radiat Oncol, Salt Lake City, UT USA
[8] Univ Wisconsin, Sch Med & Publ Hlth, Dept Human Oncol, Madison, WI USA
基金
美国国家卫生研究院;
关键词
collimation; dose calculation; dynamic collimation system (DCS); dynamic collimation; pencil beam scanning (PBS); proton therapy; spot scanning; SPOT SIZE; CONFORMITY;
D O I
10.1002/mp.17295
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe dynamic collimation system (DCS) provides energy layer-specific collimation for pencil beam scanning (PBS) proton therapy using two pairs of orthogonal nickel trimmer blades. While excellent measurement-to-calculation agreement has been demonstrated for simple cube-shaped DCS-trimmed dose distributions, no comparison of measurement and dose calculation has been made for patient-specific treatment plans.PurposeTo validate a patient-specific quality assurance (PSQA) process for DCS-trimmed PBS treatment plans and evaluate the agreement between measured and calculated dose distributions.MethodsThree intracranial patient cases were considered. Standard uncollimated PBS and DCS-collimated treatment plans were generated for each patient using the Astroid treatment planning system (TPS). Plans were recalculated in a water phantom and delivered at the Miami Cancer Institute (MCI) using an Ion Beam Applications (IBA) dedicated nozzle system and prototype DCS. Planar dose measurements were acquired at two depths within low-gradient regions of the target volume using an IBA MatriXX ion chamber array.ResultsMeasured and calculated dose distributions were compared using 2D gamma analysis with 3%/3 mm criteria and low dose threshold of 10% of the maximum dose. Median gamma pass rates across all plans and measurement depths were 99.0% (PBS) and 98.3% (DCS), with a minimum gamma pass rate of 88.5% (PBS) and 91.2% (DCS).ConclusionsThe PSQA process has been validated and experimentally verified for DCS-collimated PBS. Dosimetric agreement between the measured and calculated doses was demonstrated to be similar for DCS-collimated PBS to that achievable with noncollimated PBS.
引用
收藏
页码:5901 / 5910
页数:10
相关论文
共 50 条
  • [1] Patient-Specific Quality Assurance of Dynamically Collimated Pencil Beam Scanned Proton Therapy Treatment Plans
    Bennett, L.
    Hyer, D. E.
    Vu, N.
    Patwardhan, K. A.
    Erhart, K. J.
    Gutierrez, A. N.
    Pons, E.
    Jensen, E.
    Ubau, M.
    Zapata, J.
    Wroe, A. J.
    Wake, K. K.
    Nelson, N. P.
    Culberson, W. S.
    Smith, R.
    Hill, P. M.
    Flynn, R. T.
    MEDICAL PHYSICS, 2024, 51 (10) : 7798 - 7798
  • [2] Spot-Scanning Proton Therapy Patient-Specific Quality Assurance: Our Methodology and Results From 295 Treatment Plans
    Mackin, D.
    Zhang, X.
    Li, Y.
    Li, H.
    Wu, R.
    Poenisch, F.
    Suzuki, K.
    Kerr, M.
    Holmes, C.
    Zhu, X.
    Sahoo, N.
    Gillin, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 429 - 429
  • [3] A deterministic algorithm for patient-specific quality assurance in online adaptive proton therapy
    Burlacu, T.
    Lathouwers, D.
    Perko, Z.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S78 - S79
  • [4] Use of treatment log files in spot scanning proton therapy as part of patient-specific quality assurance
    Li, Heng
    Sahoo, Narayan
    Poenisch, Falk
    Suzuki, Kazumichi
    Li, Yupeng
    Li, Xiaoqiang
    Zhang, Xiaodong
    Lee, Andrew K.
    Gillin, Michael T.
    Zhu, X. Ronald
    MEDICAL PHYSICS, 2013, 40 (02)
  • [5] Patient specific quality assurance in proton therapy
    Amos, R.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S3 - S3
  • [6] Towards Effective and Efficient Patient-Specific Quality Assurance for Spot Scanning Proton Therapy
    Zhu, X. Ronald.
    Li, Yupeng
    Mackin, Dennis
    Li, Heng
    Poenisch, Falk
    Lee, Andrew K.
    Mahajan, Anita
    Frank, Steven J.
    Gillin, Michael T.
    Sahoo, Narayan
    Zhang, Xiaodong
    CANCERS, 2015, 7 (02): : 631 - 647
  • [7] A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans
    Li, Guangjun
    Wu, Kui
    Peng, Guang
    Zhang, Yingjie
    Bai, Sen
    MEDICAL DOSIMETRY, 2014, 39 (04) : 309 - 313
  • [8] Highly efficient and sensitive patient-specific quality assurance for spot-scanned proton therapy
    Johnson, J. E.
    Beltran, C.
    Tseung, H. Wan Chan
    Mundy, D. W.
    Kruse, J. J.
    Whitaker, T. J.
    Herman, M. G.
    Furutani, K. M.
    PLOS ONE, 2019, 14 (02):
  • [9] Application of Six Sigma Approach to Improve the Efficiency of Patient-Specific Quality Assurance in Proton Therapy
    Rah, J. E.
    Shin, D.
    Kim, T. H.
    Kim, G. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E538 - E539
  • [10] Beam Parameters of Pediatric Plans with a Pencil Beam Scanning Proton System and Their Effects On Patient-Specific Quality Assurance
    Al-ward, S.
    Zhao, L.
    MEDICAL PHYSICS, 2020, 47 (06) : E710 - E710