Rapid identification and quantification of Pseudostellaria heterophylla with its adulterants by HPLC-CAD fingerprint combined with improved quantitative analysis of multi-components by single marker (QAMS)

被引:1
|
作者
Zhu, Baojie [1 ,2 ,3 ]
Hu, Dejun [1 ,2 ,6 ]
Zhao, Jing [1 ,2 ,3 ,4 ,5 ]
Li, Shaoping [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Macau, Joint Lab Chinese Herbal Glycoengn & Testing Techn, Zhuhai 999078, Macao, Peoples R China
[2] Natl Glycoengn Res Ctr, Zhuhai 999078, Macao, Peoples R China
[3] Univ Macau, Inst Chinese Med Sci, State Key Lab Qual Res Chinese Med, Zhuhai 999078, Macao, Peoples R China
[4] Univ Macau, Macao Ctr Testing Chinese Med, Zhuhai 999078, Macau, Peoples R China
[5] Univ Macau, Fac Hlth Sci, Dept Pharmaceut Sci, Zhuhai 999078, Macao, Peoples R China
[6] China Pharmaceut Univ, Coll Engn, Natl R&D Ctr Chinese Herbal Med Proc, Dept Food Qual & Safety, Nanjing 211198, Peoples R China
关键词
Charged aerosol detector; Pseudostellaria heterophylla; Adulterants; Oligosaccharides; Improved quantitative analysis of multi components with a single marker; Relative conversion factors; PERFORMANCE LIQUID-CHROMATOGRAPHY; CHARGED AEROSOL DETECTION;
D O I
10.1016/j.jpba.2024.116205
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The P. heterophylla and its adulterants were identified by HPLC-CAD fingerprint of sucrose and oligosaccharides in P. heterophylla . The improved quantitative analysis of multi -components with a single marker (iQAMS) was further established for simultaneous determinations of sucrose and oligosaccharides in P. heterophylla . The HPLCCAD fingerprint and similarity coefficients between P. heterophylla and its adulterants showed significant differences. The relative errors (REs) between iQAMS method and external standard method (ESM) were below 3.00%, but significant difference was shown between iQAMS (different marker for whole program with gradient elution) and QAMS (one marker for whole program with gradient elution), indicating that QAMS method should be improved, especially for gradient elution which influence the response of analytes. The accuracy, precision, reproducibility, and stability of this method were validated which exhibited satisfactory results, indicating that iQAMS method could be used for quantitative analysis of sucrose and oligosaccharides in P. heterophylla instead of ESM. The iQAMS combined with HPLC-CAD fingerprint could be used to determine the content of each oligosaccharide, and it can be used for quality control of P. heterophylla .
引用
收藏
页数:7
相关论文
共 32 条
  • [31] Unsaturated fatty-acid based HPLC fingerprints in combination with quantitative analysis of multi-components by single-marker for the classification of Rana chensinensis ovum
    Zhang, Changli
    Li, Nan
    Wang, Zhongyao
    Wang, Shihan
    Wang, Zhihan
    Fan, Xuanrui
    Xu, Xinxin
    Zhou, Yue
    Wang, Yongsheng
    NEW JOURNAL OF CHEMISTRY, 2022, 46 (21) : 10441 - 10450
  • [32] Absolute Quantification of Acylcarnitines Using Integrated Tmt-PP Derivatization-Based LC-MS/MS and Quantitative Analysis of Multi-Components by a Single Marker Strategy
    Tang, Tian
    Zhang, Pei
    Li, Siqi
    Xu, Doudou
    Li, Wei
    Tian, Yuan
    Jiao, Yu
    Zhang, Zunjian
    Xu, Fengguo
    ANALYTICAL CHEMISTRY, 2021, 93 (38) : 12973 - 12980