AEROTHERMAL SIMULATIONS AND TESTING OF AN AIR-COOLED APU BAY

被引:0
|
作者
Ostino, Leandre [1 ]
Combebias, Sebastien [2 ]
Demolis, Jacques [2 ]
机构
[1] Safran Power Units, Toulouse, France
[2] Safran Helicopter Engines, Bordes, France
关键词
Computational Fluid Dynamics (CFD); convective heat transfer; Cooling; Temperature; Gas Turbine;
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
An Auxiliary Power Unit (APU) is an additional gas turbine engine located in a bay on an aircraft or a helicopter. The APU may be used to start the main engines, provide pressurized air to the cabin and generate electricity. Some of the equipment of the APU, such as the fuel metering pump or the ignitor, have certified temperature limits that must not be exceeded. In order to control the thermal environment around the APU, where these equipment are located, the bay needs to be cooled down when the APU is in operation. In this study, bay cooling is achieved with an ejector system. Numerical simulations using ANSYS Fluent with a RANS (Reynolds Averaged Navier-Stokes) approach and a k-. SST turbulence model have been performed to study the thermal environment of the APU in the bay. The volume inside the compartment, including many details such as oil and fuel ducts, was meshed using a complex wrapping process. The air-oil heat exchanger located at the inlet of the bay was modeled as a porous zone. Radiative, conductive and convective heat transfers were taken into account. The cooling mass flow through the bay and the surface temperature of all components were calculated. These calculations have been compared to the results of a test campaign performed in a dedicated facility. During the tests, the APU was installed in a bay representative of the installation on the helicopter. The inlet of the bay was equipped with a calibrated bell mouth and thermal probes were installed on most of the equipment to monitor their temperature. Static and total pressure probes were also installed in the bay to evaluate the total pressure loss of the cooling flow. The comparisons between numerical and test results showed good correlation regarding the surface temperatures.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Simulating an air-cooled turbine to restrict testing to whole engine verification
    Connolly, CF
    AEROSPACE APPLICATION OF COMPUTATIONAL METHODS VERSUS TESTING, 1998, 1998 (14): : 59 - 71
  • [22] THE DESIGN AND TESTING OF AIR-COOLED BLADING FOR AN INDUSTRIAL GAS-TURBINE
    HANNIS, JM
    SMITH, MKD
    JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1983, 105 (03): : 466 - 473
  • [23] Coupled Heat Transfer Simulations of Air-cooled Turbines with an Algebraic Transition Model
    Wang, Qiang
    Guo, Zhao-yuan
    Feng, Guo-tai
    FUTURE MATERIAL RESEARCH AND INDUSTRY APPLICATION, PTS 1 AND 2, 2012, 455-456 : 1153 - +
  • [24] Ventilation structure improvement of air-cooled induction motor using multiphysics simulations
    Zhang, Yujiao
    Huang, Xiongfeng
    Huang, Tao
    Ruan, Jiangjun
    Wu, Xiaowen
    Telkomnika - Indonesian Journal of Electrical Engineering, 2012, 10 (03): : 451 - 458
  • [25] Coupled heat transfer simulations of an air-cooled turbine with single cooling channel
    Wang, Qiang
    Guo, Zhao-Yuan
    Zhou, Chi
    Feng, Guo-Tai
    Wang, Zhong-Qi
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2011, 26 (01): : 78 - 84
  • [26] Choice of the air-cooled chiller and the water cooled chiller
    Wu, Haicheng
    Nuantong Kongtiao/HV & AC, 1995, 25 (06): : 49 - 51
  • [27] Optimum placement for air-cooled chillers
    Khankari, Kishor, 1600, ASHRAE (58):
  • [28] Design and testing of a novel air-cooled condenser for concentrated solar power plants
    Moore, J.
    Grimes, R.
    O'Donovan, A.
    Walsh, E.
    PROCEEDINGS OF THE SOLARPACES 2013 INTERNATIONAL CONFERENCE, 2014, 49 : 1439 - 1449
  • [30] Air-cooled aircraft engines.
    Gosslau, F
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1924, 68 : 921 - 925