Efficient cascade waste heat utilization using thermoacoustic engine with variable temperature heat sources

被引:2
|
作者
Hu, Yiwei [1 ,2 ]
Jiang, Zhijie [1 ,3 ,4 ]
Luo, Kaiqi [5 ]
Zhao, Dan [6 ]
Chen, Yuanhang [1 ,2 ]
Chen, Geng [7 ]
Luo, Ercang [1 ,2 ]
Xu, Jingyuan [8 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen Sci & Technol, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Peoples R China
[4] Inst Serv oriented Mfg Hangzhou CO LTD, Hangzhou 310027, Peoples R China
[5] Chinese Acad Sci, Inst Proc Engn, State Key Lab Mesosci & Engn, Beijing 100190, Peoples R China
[6] Univ Canterbury, Coll Engn, Dept Mech Engn, Private Bag 4800, Christchurch 8041, New Zealand
[7] Southeast Univ, Natl Engn Res Ctr Power Generat Control & Safety, Sch Energy & Environm, Nanjing 210096, Peoples R China
[8] Karlsruhe Inst Technol, Inst Microstruct Technol, D-76344 Karlsruhe, Germany
基金
中国国家自然科学基金;
关键词
Thermoacoustic; Multi-stage heat exchangers; Waste heat recovery; Bypasses; RECOVERY; PERFORMANCE; CRYOCOOLER;
D O I
10.1016/j.enconman.2024.118662
中图分类号
O414.1 [热力学];
学科分类号
摘要
Waste heat recovery is vital for greenhouse gas emissions reduction and meeting increasing power demands. Thermoacoustic engines present a promising solution. However, existing research predominantly focuses on single heating temperatures, which restricts their efficiency in harnessing heat sources with variable temperatures. To overcome this limitation, this work proposed a novel concept of thermoacoustic engine containing multistage heat exchangers capable of cascade waste heat recovery by incorporating bypass orifices to address this issue. By organizing decreasing temperatures of heat source across heat exchangers with decreasingly lower temperatures, multiple heat-to-power energy conversions can be achieved. Theoretical analyses demonstrate that the total exergy utilization efficiency of single-stage (37.7 %), two-stage (47.6 %), and three-stage systems (51.2 %) significantly increases when increasing the stage number up to three. Further increasing the stage number results in less efficiency improvement (only a 1.3 % increase in a four-stage system). Simulation results show that the three-stage thermoacoustic engine can achieve an acoustic power of 2.7 kW and a total exergy utilization efficiency of 51.2 % for recovering 12 kW variable-temperature heat sources. Coupling the engine with a linear alternator increases electricity production by 12 % with higher waste heat utilization rate compared to traditional single-stage thermoacoustic generators. The experimental results further underscore the capability of the proposed thermoacoustic generator to effectively utilize heat sources with variable temperatures.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Integration of industrial solar and gaseous waste heat into heat recovery loops using constant and variable temperature storage
    Walmsley, Timothy G.
    Walmsley, Michael R. W.
    Atkins, Martin J.
    Neale, James R.
    ENERGY, 2014, 75 : 53 - 67
  • [42] Shaft Power Extraction and Waste Heat Rejection using a Three Stream Variable Cycle Engine
    Corbett, Michael
    SAE INTERNATIONAL JOURNAL OF AEROSPACE, 2012, 5 (02): : 371 - 385
  • [43] Laboratory tests on heat treatment of ballast water using engine waste heat
    Balaji, Rajoo
    Siang, Hing Lee
    Yaakob, Omar
    Koh, Kho King
    bin Adnan, Faizul Amri
    bin Ismail, Nasrudin
    bin Ahmad, Badruzzaman
    bin Ismail, Mohd Arif
    Nik, W. B. Wan
    ENVIRONMENTAL TECHNOLOGY, 2018, 39 (09) : 1102 - 1114
  • [44] Cooling Effectiveness of Thermoacoustic Heat Engine Systems Development
    Irfan, A. R.
    Zarhamdy, M. Z. M.
    Saad, S. M. Sazli
    Hafiz, H. M.
    Azlida, A.
    GREEN DESIGN AND MANUFACTURE: ADVANCED AND EMERGING APPLICATIONS, 2018, 2030
  • [45] Evaluation of Pressure Volume Characteristics for Thermoacoustic Heat Engine
    Irfan, A. R.
    Zain, M. Z. Md
    Sazli, S. M.
    Asraf, P. M. A.
    Shuaib, N. A.
    Azlida, A.
    5TH INTERNATIONAL CONFERENCE ON GREEN DESIGN AND MANUFACTURE 2019 (ICONGDM 2019), 2019, 2129
  • [46] Investigation of a portable standing wave thermoacoustic heat engine
    Normah, M. G.
    Irfan, A. R.
    Koh, K. S.
    Manet, A.
    Zaki, Ab. M.
    5TH BSME INTERNATIONAL CONFERENCE ON THERMAL ENGINEERING, 2013, 56 : 829 - 834
  • [47] Dsign and experimental verification of a heater for thermoacoustic heat engine
    Sun, Da-Ming
    Qiu, Li-Min
    Yan, Wei-Lin
    Chen, Ping
    Can, Zhi-Hua
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2004, 25 (02): : 226 - 228
  • [48] Numerical investigation on a thermoacoustic heat engine unit with a displacer
    Zhang, S.
    Wu, Z. H.
    Zhao, R. D.
    Dai, W.
    Luo, E. C.
    ENERGY CONVERSION AND MANAGEMENT, 2014, 85 : 793 - 799
  • [49] How to Match an Acoustical Load to a Thermoacoustic Heat Engine?
    Zhang, L. M.
    Chen, Y. Y.
    Luo, E. C.
    ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 1445 - 1452
  • [50] A thermoacoustic-Stirling heat engine: Detailed study
    Backhaus, S
    Swift, GW
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 107 (06): : 3148 - 3166