A Cadaveric Study: Does Ankle Positioning Affect the Quality of Anatomic Syndesmosis Reduction?

被引:0
|
作者
Aneja, Arun [1 ]
Nazal, Mark R. [2 ]
Griffin, Jarod T. [1 ]
Foster, Jeffrey A. [1 ]
Muhammad, Maaz [1 ]
Sierra-Arce, Carlos R. [1 ]
Southall, Wyatt G. S. [2 ]
Wagner, Robert Kaspar [1 ]
Ly, Thuan V. [1 ]
Srinath, Arjun [3 ]
机构
[1] Massachusetts Gen Hosp, Brigham & Womens Hosp, Harvard Med Sch Orthoped Trauma Initiat, Boston, MA USA
[2] Univ Kentucky, Dept Orthopaed Surg & Sports Med, Lexington, KY USA
[3] Univ Miami Hosp, Dept Orthopaed Surg, Miami, FL USA
关键词
syndesmosis; plantarflexion; dorsiflexion; reduction; cadaver; ankle; SCREW FIXATION; MALREDUCTION; JOINT; DISRUPTIONS; INJURIES;
D O I
10.1097/BOT.0000000000002827
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
OBJECTIVE: The objective of this study was to compare the quality of syndesmotic reduction with the ankle in maximal dorsiflexion versus neutral plantarflexion (normal resting position). METHODS: Baseline computed tomography (CT) imaging of 10 cadaveric ankle specimens from 5 donors was obtained with the ankles placed in normal resting position. Two fellowship-trained orthopaedic surgeons disrupted the syndesmosis of each ankle specimen. All ankles were then placed in neutral plantarflexion and were subsequently reduced with thumb pressure under direct visualization through an anterolateral approach and stabilized with one 0.062-inch K-wire placed from lateral to medial in a quadricortical fashion across the syndesmosis. Postreduction CT scans were then obtained with the ankle in normal resting position. This process was repeated with the ankles placed in maximal dorsiflexion during reduction and stabilization. Postreduction CT scans were then obtained with the ankles placed in normal resting position. All postreduction CT scans were compared with baseline CT imaging using mixed-effects linear regression with significance set at P < 0.05. RESULTS: Syndesmotic reduction and stabilization in maximal dorsiflexion led to increased external rotation of the fibula compared with baseline scans [13.0 +/- 5.4 degrees (mean +/- SD) vs. 7.5 +/- 2.4 degrees, P = 0.002]. There was a tendency toward lateral translation of the fibula with the ankle reduced in maximal dorsiflexion (3.3 +/- 1.0 vs. 2.7 +/- 0.7 mm, P = 0.096). No other statistically significant differences between measurements of reduction with the ankle placed in neutral plantarflexion or maximal dorsiflexion compared with baseline were present (P > 0.05). CONCLUSIONS: Reducing the syndesmosis with the ankle in maximal dorsiflexion may lead to malreduction with external rotation of the fibula. There was no statistically significant difference in reduction quality with the ankle placed in neutral plantarflexion compared with baseline. Future studies should assess the clinical implications of ankle positioning during syndesmotic fixation.
引用
收藏
页码:e307 / e311
页数:5
相关论文
共 50 条
  • [21] Syndesmosis reduction by computer-assisted orthopaedic surgery with navigation: Feasibility and accuracy in a cadaveric study
    Dubois-Ferriere, Victor
    Gamulin, Axel
    Chowdhary, Ashwin
    Fasel, Jean
    Stern, Richard
    Assal, Mathieu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (12): : 2694 - 2699
  • [22] A Novel Indirect Reduction Technique in Ankle Syndesmotic Injuries: A Cadaveric Study
    Cosgrove, Christopher T.
    Spraggs-Hughes, Amanda G.
    Putnam, Sara M.
    Ricci, William M.
    Miller, Anna N.
    McAndrew, Christopher M.
    Gardner, Michael J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (07) : 361 - 367
  • [23] Does the quality of preoperative closed reduction of displaced ankle fractures affect wound complications after surgical fixation?
    Chien, Bonnie Y.
    Stupay, Kristen L.
    Miller, Christopher P.
    Smith, Jeremy T.
    Briceno, Jorge
    Kwon, John Y.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (10): : 1931 - 1935
  • [24] Does Proximal Placement of the Syndesmotic Reduction Clamp Affect the Optimal Position for the Medial Tine? A Cadaveric Pilot Study
    Rushing, Calvin J.
    Spinner, Steven M.
    Armstrong, Albert V., Jr.
    JOURNAL OF FOOT & ANKLE SURGERY, 2022, 61 (01): : 3 - 6
  • [25] Kinematics and Laxity of the Ankle Joint in Anatomic and Nonanatomic Anterior Talofibular Ligament Repair: A Biomechanical Cadaveric Study
    Shoji, Hiroaki
    Teramoto, Atsushi
    Sakakibara, Yuzuru
    Kamiya, Tomoaki
    Watanabe, Kota
    Fujie, Hiromichi
    Yamashita, Toshihiko
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (03): : 667 - 673
  • [27] Use of Anatomical Landmarks in Ankle Arthroscopy to Determine Accuracy of Syndesmotic Reduction: A Cadaveric Study
    Cassinelli, Spenser J.
    Harris, Thomas G.
    Giza, Eric
    Kreulen, Christopher
    Matheny, Lauren M.
    Robbins, Colin M.
    Clanton, Thomas O.
    FOOT & ANKLE SPECIALIST, 2020, 13 (03) : 219 - 227
  • [28] Double-bundle "anatomic" anterior cruciate ligament reconstruction: A cadaveric study of tunnel positioning with a transtibial technique
    Giron, Francesco
    Cuomo, Pierluigi
    Edwards, Andrew
    Bull, Anthony M. J.
    Amis, Andrew A.
    Aglietti, Paolo
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (01): : 7 - 13
  • [29] Computed Tomography Analysis for Quantification of Displacement of the Distal Fibula in Different Foot Positions With Weightbearing and Sequentially Increased Instability: An Anatomic Cadaveric Study on Syndesmosis
    Hagen, Jennifer E.
    Rausch, Sascha
    Simons, Paul
    Richards, R. Geoff
    Lenz, Mark
    Knobe, Matthias
    Gueorguiev, Boyko
    Klos, Kajetan
    JOURNAL OF FOOT & ANKLE SURGERY, 2019, 58 (04): : 734 - 738
  • [30] Extensor retinaculum excision does not affect wrist tendon forces: a cadaveric simulator study
    Shah, Darshan S.
    Horwitz, Maxim D.
    Kedgley, Angela E.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (09) : 986 - 988