A Cadaveric Study: Does Ankle Positioning Affect the Quality of Anatomic Syndesmosis Reduction?

被引:0
|
作者
Aneja, Arun [1 ]
Nazal, Mark R. [2 ]
Griffin, Jarod T. [1 ]
Foster, Jeffrey A. [1 ]
Muhammad, Maaz [1 ]
Sierra-Arce, Carlos R. [1 ]
Southall, Wyatt G. S. [2 ]
Wagner, Robert Kaspar [1 ]
Ly, Thuan V. [1 ]
Srinath, Arjun [3 ]
机构
[1] Massachusetts Gen Hosp, Brigham & Womens Hosp, Harvard Med Sch Orthoped Trauma Initiat, Boston, MA USA
[2] Univ Kentucky, Dept Orthopaed Surg & Sports Med, Lexington, KY USA
[3] Univ Miami Hosp, Dept Orthopaed Surg, Miami, FL USA
关键词
syndesmosis; plantarflexion; dorsiflexion; reduction; cadaver; ankle; SCREW FIXATION; MALREDUCTION; JOINT; DISRUPTIONS; INJURIES;
D O I
10.1097/BOT.0000000000002827
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
OBJECTIVE: The objective of this study was to compare the quality of syndesmotic reduction with the ankle in maximal dorsiflexion versus neutral plantarflexion (normal resting position). METHODS: Baseline computed tomography (CT) imaging of 10 cadaveric ankle specimens from 5 donors was obtained with the ankles placed in normal resting position. Two fellowship-trained orthopaedic surgeons disrupted the syndesmosis of each ankle specimen. All ankles were then placed in neutral plantarflexion and were subsequently reduced with thumb pressure under direct visualization through an anterolateral approach and stabilized with one 0.062-inch K-wire placed from lateral to medial in a quadricortical fashion across the syndesmosis. Postreduction CT scans were then obtained with the ankle in normal resting position. This process was repeated with the ankles placed in maximal dorsiflexion during reduction and stabilization. Postreduction CT scans were then obtained with the ankles placed in normal resting position. All postreduction CT scans were compared with baseline CT imaging using mixed-effects linear regression with significance set at P < 0.05. RESULTS: Syndesmotic reduction and stabilization in maximal dorsiflexion led to increased external rotation of the fibula compared with baseline scans [13.0 +/- 5.4 degrees (mean +/- SD) vs. 7.5 +/- 2.4 degrees, P = 0.002]. There was a tendency toward lateral translation of the fibula with the ankle reduced in maximal dorsiflexion (3.3 +/- 1.0 vs. 2.7 +/- 0.7 mm, P = 0.096). No other statistically significant differences between measurements of reduction with the ankle placed in neutral plantarflexion or maximal dorsiflexion compared with baseline were present (P > 0.05). CONCLUSIONS: Reducing the syndesmosis with the ankle in maximal dorsiflexion may lead to malreduction with external rotation of the fibula. There was no statistically significant difference in reduction quality with the ankle placed in neutral plantarflexion compared with baseline. Future studies should assess the clinical implications of ankle positioning during syndesmotic fixation.
引用
收藏
页码:e307 / e311
页数:5
相关论文
共 50 条
  • [1] Forceps Reduction of the Syndesmosis in Rotational Ankle Fractures A Cadaveric Study
    Phisitkul, Phinit
    Ebinger, Thomas
    Goetz, Jessica
    Vaseenon, Tanawat
    Marsh, J. Lawrence
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (24): : 2256 - 2261
  • [2] Sagittal ankle position does not affect axial CT measurements of the syndesmosis in a cadaveric model
    Ashley E. Levack
    Aleksey Dvorzhinskiy
    Elizabeth B. Gausden
    Matthew R. Garner
    Stephen J. Warner
    Peter D. Fabricant
    Dean G. Lorich
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 25 - 31
  • [3] Sagittal ankle position does not affect axial CT measurements of the syndesmosis in a cadaveric model
    Levack, Ashley E.
    Dvorzhinskiy, Aleksey
    Gausden, Elizabeth B.
    Garner, Matthew R.
    Warner, Stephen J.
    Fabricant, Peter D.
    Lorich, Dean G.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (01) : 25 - 31
  • [4] Radiological indicator of reduction adequacy during ankle syndesmosis surgery: A computational cadaveric study
    Lee, Jun-Young
    Lim, Jae Hwan
    Jung, Gu-Hee
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (08): : 1491 - 1496
  • [5] The fate of the syndesmosis in type C ankle fractures: A cadaveric study
    Harris, IA
    Jones, HP
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (04): : 275 - 277
  • [6] Does the angle and position of the syndesmosis screw in the axial plan affect the reduction of syndesmosis?
    Karagoz, Bekir
    Oral, Rudvan Mete
    Bombaci, Hasan
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2022, 13 (04): : 435 - 439
  • [7] Quantification of manipulation forces needed for robot-assisted reduction of the ankle syndesmosis: an initial cadaveric study
    Gebremeskel, Mikias
    Shafiq, Babar
    Uneri, Ali
    Sheth, Niral
    Simmerer, Corey
    Zbijewski, Wojciech
    Siewerdsen, Jeffrey H.
    Cleary, Kevin
    Li, Gang
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (12) : 2263 - 2267
  • [8] Quantification of manipulation forces needed for robot-assisted reduction of the ankle syndesmosis: an initial cadaveric study
    Mikias Gebremeskel
    Babar Shafiq
    Ali Uneri
    Niral Sheth
    Corey Simmerer
    Wojciech Zbijewski
    Jeffrey H. Siewerdsen
    Kevin Cleary
    Gang Li
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 2263 - 2267
  • [9] The fate of the syndesmosis in type C ankle fractures: a cadaveric study - Reply
    Colton, C
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (03): : 250 - 251
  • [10] Effect of a Dynamic Fixation Construct on Syndesmosis Reduction: A Cadaveric Study
    Honeycutt, M. Wesley
    Riehl, John T.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (09) : 460 - 464