A time-dependent method for the measurement of mass flow rate of gases in microchannels

被引:14
|
作者
Silva, Ernane [1 ]
Deschamps, Cesar J. [1 ]
Rojas-Cardenas, Marcos [2 ]
Barrot-Lattes, Christine [2 ]
Baldas, Lucien [2 ]
Colin, Stephane [2 ]
机构
[1] Univ Fed Santa Catarina, POLO Res Labs Emerging Technol Cooling & Thermoph, BR-88048300 Florianopolis, SC, Brazil
[2] UPS, Univ Toulouse, CNRS, INSA,ISAE SUPAERO,ICA,Mines Albi, 3 Rue Caroline Aigle, F-31400 Toulouse, France
关键词
Transient flow; Rarefied gas; Microchannel; Accommodation coefficient; SLIP-FLOW; ACCOMMODATION; MICROTUBES; NITROGEN; VACUUM;
D O I
10.1016/j.ijheatmasstransfer.2017.11.147
中图分类号
O414.1 [热力学];
学科分类号
摘要
Accurate measurement methods are required in the analysis of thermodynamic non-equilibrium effects associated with rarefied gas flows. For example, for the specific case of accommodation coefficients measurements, the quantity of interest is often the mass flow rate along the channel. For this purpose, the following paper presents a new time-dependent version of the well-known constant volume method for the accurate measurement of mass flow rates of gases in microchannels. The technique proposed here is an improvement in respect to the classic technique since it can be used for transient experiments. Moreover, it can be applied to configurations with arbitrary upstream and downstream reservoirs dimensions. Particularly, the proposed method relies on the assumption that the flow conductance varies linearly during the experiments and thus the pressure variations in the reservoirs can be fitted by a well-defined exponential function. Then, the instantaneous mass flow rate through the channel can be determined directly from the pressure fitting coefficients. A great advantage of the time-dependent constant volume method is that the measurements can be obtained from a single experiment for a wide range of rarefaction conditions, since the mean pressure between the reservoirs is allowed to change with time. Moreover, this technique represents a convenient manner to provide raw data of pressure variation with time in the reservoirs and transient mass flow rate in the channel by simply providing the fitting coefficients of the theoretically derived functions. A clear geometric criterion is also presented to determine when such mass flow rate measurements can be considered as quasi-steady, corresponding closely to results obtained under steady conditions, when ideally the channel connects two infinite reservoirs at different pressures. Results for flows of nitrogen through a stainless steel microtube (L = 92.22 +/- 0.01 mm and D = 435.5 +/- 3.5 mu m) were obtained from 118 independent experiments, provided in this work, using two different experimental setups and three different configurations of the system volumes. As expected, no deviation was observed between all experimental campaigns in terms of the reduced mass flow rate. In addition, all results indicate that nitrogen can be considered completely accommodated at the surface of the microtube used, with alpha = 0.986 +/- 0.019 when the diffuse-specular gas-surface interaction model is adopted and alpha(t) 0.991 +/- 0.020 (alpha(n) = 1) when the Cercignani-Lampis model is adopted. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:422 / 434
页数:13
相关论文
共 50 条
  • [21] COMPUTATION OF STEADY NOZZLE-FLOW BY A TIME-DEPENDENT METHOD
    CLINE, MC
    AIAA JOURNAL, 1974, 12 (04) : 419 - 420
  • [22] TIME-DEPENDENT FLOW IN A LAKE
    HAQ, A
    LICK, W
    JOURNAL OF GEOPHYSICAL RESEARCH, 1975, 80 (03): : 431 - 437
  • [23] Defect correction method for time-dependent viscoelastic fluid flow
    Zhang, Yunzhang
    Hou, Yanren
    Mu, Baoying
    INTERNATIONAL JOURNAL OF COMPUTER MATHEMATICS, 2011, 88 (07) : 1546 - 1563
  • [24] A new Lagrangian method for time-dependent inviscid flow computation
    Loh, CY
    Hui, WH
    SIAM JOURNAL ON SCIENTIFIC COMPUTING, 2000, 22 (01): : 330 - 350
  • [25] Time-dependent methodology for non-stationary mass flow rate measurements in a long micro-tube
    Rojas-Cardenas, Marcos
    Silva, Ernane
    Ho, Minh-Tuan
    Deschamps, Cesar J.
    Graur, Irina
    MICROFLUIDICS AND NANOFLUIDICS, 2017, 21 (05)
  • [26] NUMERICAL-SOLUTIONS FOR TIME-DEPENDENT HYDRODYNAMIC FLOW WITH MASS LOADING
    KOMLE, NI
    LICHTENEGGER, HIM
    PLANETARY AND SPACE SCIENCE, 1986, 34 (04) : 403 - 408
  • [27] Time-dependent rarefied gas flow of single gases and binary gas mixtures into vacuum
    Vargas, Manuel
    Naris, Steryios
    Valougeorgis, Dimitris
    Pantazis, Sarantis
    Jousten, Karl
    VACUUM, 2014, 109 : 385 - 396
  • [28] A class of exact solutions of the time-dependent Schrodinger equation with time-dependent mass
    Schulze-Halberg, A
    MODERN PHYSICS LETTERS A, 2001, 16 (40) : 2557 - 2566
  • [29] THE PROPAGATOR FOR A TIME-DEPENDENT MASS SUBJECT TO A HARMONIC POTENTIAL WITH A TIME-DEPENDENT FREQUENCY
    DESOUZA, CF
    DUTRA, AD
    PHYSICS LETTERS A, 1987, 123 (06) : 297 - 301
  • [30] Instantaneous flow rate measurement of ideal gases
    Kawashima, K
    Kagawa, T
    Fujita, T
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2000, 122 (01): : 174 - 178