Design method of a focusing dielectric lens antenna and temperature increment measurement at the focusing spot

被引:2
|
作者
Abd Rahman, Amirah [1 ]
Kamardin, Kamilia [1 ,2 ]
Yamada, Yoshihide [1 ]
Takahashi, Masaharu [3 ]
机构
[1] Univ Teknol Malaysia, Malaysia Japan Int Inst Technol, Dept Elect Syst Engn, Kuala Lumpur, Malaysia
[2] Univ Teknol Malaysia, Wireless Commun Ctr, Kuala Lumpur, Malaysia
[3] Chiba Univ, Ctr Frontier Med Engn, Chiba, Japan
关键词
Radio wave hyperthermia; Dielectric lens antenna; Small focal spot; Human body phantom; HYPERTHERMIA;
D O I
10.1016/j.heliyon.2024.e28061
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In radio wave hyperthermia therapy, array antenna configuration was mainly studied to generate a small spot at the diseased part. Array antennas have the flexibility in controlling radiation performance, such as spot positions, by using their numerous radiating elements. However, the flexibility is achieved at the expense of antenna structure complexity. On the other hand, a lens antenna can concentrate radio waves into a small spot by forming a lens shape. The simplicity of a lens antenna structure lends itself to easy handling in a practical application. Moreover, the frequency independence of the lens antenna allows for a more flexible selection of hyperthermia therapy frequencies. Therefore, the lens antenna is selected as a focusing antenna in this paper. The lens shaping method and the temperature increment measurement are the main contents of this paper. The designed lens has a diameter of 30 cm, a focusing distance of 30 cm, and a working frequency of 2.45 GHz. A thin lens design method is applied to reduce lens weight. Firstly, the focusing ability of the designed lens is ensured by comparing the spot size results of electromagnetic (EM) simulation with its theoretical value. A spot size of 1.77 cm is obtained in both cases. Next, the temperature increment is examined by EM simulations. The temperature at the 2 cm tumor was increased to 41 degrees C from the human body temperature of 37 degrees C by an input power of 10 Watts (W). For the temperature increment measurement, a tumor within human body phantom is utilized and the available input power is reduced to 4 W. The tumor temperature increased from 21.5 degrees C of room temperature to 24.4 degrees C, which was captured by a thermal imaging camera. As a result, the functionality of the lens antenna for hyperthermia therapy is verified.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] A Focusing Method of Liquid Lens Based on Capacitance Detection
    Zheng, Kang
    Huang, Xiang
    Wu, Mu-Han
    He, Gong-Han
    Wang, Ling-Yun
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2024, 36 (01) : 51 - 54
  • [42] FDTD Simulation for the Focusing Property of Extended Hemispherical Lens as Receiving Antenna
    W. B. Dou
    Edward K. N. Yung
    International Journal of Infrared and Millimeter Waves, 2000, 21 : 2077 - 2086
  • [44] Design of an antipodal vivaldi antenna focusing on constructional aspects
    Cabral D.S.
    Manera L.
    Zoccal L.B.
    Ferreira D.B.
    Prudenzano F.
    Journal of Microwaves, Optoelectronics and Electromagnetic Applications, 2021, 20 (04): : 777 - 789
  • [45] Subwavelength light focusing of plasmonic lens with dielectric filled nanoslits structures
    Wang, Hao
    Deng, Yongqiang
    He, Jiayu
    Gao, Ping
    Yao, Na
    Wang, Changtao
    Zhao, Zeyu
    Wang, Jiong
    Jiang, Bo
    Luo, Xiangang
    JOURNAL OF NANOPHOTONICS, 2014, 8
  • [46] Design of terahertz devices based on dielectric metasurface: beam deflector and focusing deflector meta-lens
    Li, Xiaotong
    Li, Qiushi
    Cai, Xiaodong
    Xiao, Shiyi
    2022 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY (ICMMT), 2022,
  • [47] Focusing system with distance measurement by reflecting energy and its overlap design method
    Feng, Huajun
    Guangdian Gongcheng/Opto-Electronic Engineering, 1998, 25 (02): : 48 - 53
  • [48] THE DESIGN OF ECHO SPOT AND OPTICAL FOCUSING IN AUTOMATIC LASER TRACKING
    YANG, YH
    OPTICS AND LASER TECHNOLOGY, 1986, 18 (02): : 75 - 79
  • [49] The error analysis of pattern measurement of certain phase array antenna by focusing method in near field
    Zhang, JW
    Wang, CY
    Wang, CC
    Jing, L
    Chu, YS
    ISTM/2001: 4TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2001, : 881 - 884
  • [50] Design on internal focusing optical system with zoom lens of freeform
    Jiang T.
    Feng H.
    Li Q.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2021, 50 (04):