Suppression of Background Count by Cargo Containers in Radiation Portal Monitor

被引:0
|
作者
Sim, Hayoung [1 ]
Seo, Hee [1 ]
Yoon, Seonkwang [2 ]
Choi, Hyeonjun [3 ]
Kim, Haneul [3 ]
Jang, Jaeho [3 ]
机构
[1] Jeonbuk Natl Univ, Dept Appl Plasma & Quantum Beam Engn, Jeonju 54896, South Korea
[2] Korea Atom Energy Res Inst, Adv Fuel Cycle Technol Dev Div, Daejeon 34057, South Korea
[3] Korea Inst Nucl Safety, Dept Radiat Monitoring Ports Entry, Daejeon 34142, South Korea
关键词
Background count suppression; cargo container; Monte Carlo simulation; plastic scintillator; radiation portal monitor (RPM); SYSTEM;
D O I
10.1109/TNS.2023.3333353
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
At domestic ports and airports, radiation portal monitors (RPMs) have been installed and operated for detection of illegal radioactive materials in cargo containers. In RPM operation, although the alarm level of the RPM is set based on the background count, measured before the cargo container passes through the RPM, suppression of the background count occurs due to shielding by the cargo container and its contents. In this study, we evaluated, using Monte Carlo simulations, background-count variations caused by various conditions of cargo containers and their contents. To that end, the experimental RPM at the Port of Busan in South Korea and a 40 ft cargo container, the most commonly used type in South Korea, were precisely modeled. In order to verify the simulation models, the simulated data on the background count for the empty container were compared with the measured data, as recorded at 0.2-s intervals during container passes through the RPM. When the empty container passed through the RPM, the average background count decreased by approximately 20%-30% with a consistent tendency. It was found that the degree and shape of background suppression varied depending on the cargo conditions. For example, for various cargoes (i.e., potassium chloride, slag powder, and zircon), as the vertical loading increased, the background count varied by approximately 50%-60% on average, and by up to 74% in comparison to the time before the container entered the RPM. The present findings will contribute to the optimization of site-specific alarm criteria for RPM by better enabling realistic estimation of background variation for various factors.
引用
收藏
页码:1026 / 1032
页数:7
相关论文
共 50 条
  • [31] BACKGROUND SUPPRESSION - A NEW GENERAL METHOD IN MEASUREMENT OF IONIZING RADIATION
    BRADLEY, JES
    MARKS, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1965, 10 (02): : 191 - &
  • [32] BACKGROUND RADIATION SUPPRESSION OF A THERMAL INFRARED HYPERSPECTRAL IMAGING SYSTEM
    Wang Jian-Yu
    Xu Wei-Ming
    Yuan Li-Yin
    Lin Ying
    He Zhi-Ping
    Liu Jun
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2010, 29 (06) : 419 - +
  • [33] BACKGROUND SUPPRESSION A NEW GENERAL METHOD IN MEASUREMENT OF IONIZING RADIATION
    BRADLEY, JES
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (02): : 321 - &
  • [34] Validation of energy-weighted algorithm for radiation portal monitor using plastic scintillator
    Lee, Hyun Cheol
    Shin, Wook-Geun
    Park, Hyo Jun
    Yoo, Do Hyun
    Choi, Chang-Il
    Park, Chang-Su
    Kim, Hong-Suk
    Min, Chul Hee
    APPLIED RADIATION AND ISOTOPES, 2016, 107 : 160 - 164
  • [35] Improving operational performance using machine learning analysis of Radiation Portal Monitor measurements
    Labov, Simon E.
    Nelson, Karl E.
    Mattoon, Caleb M.
    Mcferran, Noah J.
    Pham, Minh H.
    Her, Lisa
    Brzosko, Jan S.
    Ray, Saswati
    Howarth, Dan
    Dubrawski, Artur W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1072
  • [36] Feasibility of miniature radiation portal monitor for measurement of radioactivity contamination in flowing water in pipe
    Kim, J.
    Park, K.
    Joo, K.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [37] A WIDE-RANGE TEN DECADE RADIATION MONITOR USING TIME-TO-COUNT TECHNIQUE
    DIIANNI, E
    COOLEY, HJ
    HEALTH PHYSICS, 1985, 49 (01): : 174 - 175
  • [38] EFFECT OF DEPOSITED RADON DAUGHTER PRODUCTS ON BACKGROUND COUNT RATE OF A SENSITIVE WHOLE-BODY RADIOACTIVITY MONITOR
    PARTHASA.KS
    BURKINSH.L
    MARSHALL, DH
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (05): : 706 - &
  • [39] Development of a portal-crane servo-spraying suppression system to reduce dust production at bulk cargo wharf
    Wang, Wenchao
    Huang, Fayi
    Li, Xianzhong
    INTERNATIONAL JOURNAL OF SYSTEM ASSURANCE ENGINEERING AND MANAGEMENT, 2022, 13 (03) : 1151 - 1161
  • [40] Development of a portal-crane servo-spraying suppression system to reduce dust production at bulk cargo wharf
    Wenchao Wang
    Fayi Huang
    Xianzhong Li
    International Journal of System Assurance Engineering and Management, 2022, 13 : 1151 - 1161