Modification of Oximeter Ratio to Reduce Pigmentation Bias in Pulse Oximetry

被引:0
|
作者
Arefin, Mohammed Shahriar [1 ]
Shmuylovich, Leonid [2 ,3 ]
Patil, Chetan A. [1 ]
机构
[1] Temple Univ, Dept Bioengn, Philadelphia, PA 19122 USA
[2] Washington Univ, Dept Dermatol, St Louis, MO 14263 USA
[3] Washington Univ, Dept Radiol, St Louis, MO 14263 USA
来源
DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XVII | 2024年 / 12833卷
关键词
SKIN COLOR;
D O I
10.1117/12.3003274
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Pulse oximeters are widely used in healthcare systems to estimate blood oxygen saturation level (SpO2) using red and infrared light. Recent clinical and simulation studies reported that in darkly pigmented subjects oximeter over-estimates SpO2 which could lead to higher rates of occult hypoxemia in highly pigmented subjects. The probable solutions to solve this over-estimation bias could be modification of the current oximeter design, calibration enrollment or modification of oximeter ratio (R). In this study, a modification of the current oximeter ratio (R) was presented by using different combinations of currently estimated oximeter parameters. Simulation results showed that modified oximeter ratio reduces over-estimation bias in highly pigmented subjects compared to the conventional oximeter ratio. In the regions near hypoxemia threshold (90% oxygenation level), the over-estimation bias in the simulated test cohort could reduce from 1.36% to -0.01% if modified oximeter ratio is used. Results show that modification of oximeter ratio could be used in future to improve oximeter accuracy and produce pigmentation independent outcomes.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Is pulse oximetry an essential tool or just another distraction? The role of the pulse oximeter in modern anesthesia care
    Amit Shah
    Kirk H. Shelley
    Journal of Clinical Monitoring and Computing, 2013, 27 : 235 - 242
  • [22] Is pulse oximetry an essential tool or just another distraction? The role of the pulse oximeter in modern anesthesia care
    Shah, Amit
    Shelley, Kirk H.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2013, 27 (03) : 235 - 242
  • [23] Skin Pigmentation Effects on Pulse Oximetry Accuracy Need a Prospective Study
    Blike, George T.
    McGrath, Susan P.
    McGovern, Krystal
    JOURNAL OF PATIENT SAFETY, 2023, 19 (04) : 221 - 222
  • [24] Absence of Racial Bias In Pulse Oximetry Saturation Measurement
    Fleming, Neal W.
    Marlar, Audrey
    Knabe, Bradley
    Taghikhan, Yasamin
    Yusuf, Fatima
    Applegate, Richard L.
    ANESTHESIA AND ANALGESIA, 2022, 134 : 1167 - 1168
  • [25] Racial and Ethnic Bias in Pulse Oximetry and Clinical Outcomes
    Valbuena, Valeria S. M.
    Merchant, Raina M.
    Hough, Catherine L.
    JAMA INTERNAL MEDICINE, 2022, 182 (07) : 699 - 700
  • [26] Mitigating Risks for Racial Bias in Pulse Oximetry on Children
    Verma, Sourabh
    Bailey, Sean M.
    JAMA PEDIATRICS, 2023, 177 (09) : 982 - 982
  • [27] Pulse Oximetry and Skin Pigmentation-New Guidance From the FDA
    Lipnick, Michael S.
    Ehie, Odinakachukwu
    Igaga, Elizabeth N.
    Bicker, Philip
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2025,
  • [28] OCCULT HYPOXEMIA AND PULSE OXIMETRY PERFORMANCE ACROSS SKIN PIGMENTATION GROUPS
    Ajizian, Samuel
    McGonigle, Scott
    Dove, Jake
    Ting, Yu-Jung
    Sethi, Rakesh
    Milkes, David
    CRITICAL CARE MEDICINE, 2023, 51 (01) : 509 - 509
  • [29] PULSE OXIMETER ALARMS SET TO 85% MAY LEAD TO SUBSTANTIAL PERIODS OF HYPOXEMIA DESPITE CONTINUOUS PULSE OXIMETRY
    Hopf, H. W.
    Johnson, S.
    WOUND REPAIR AND REGENERATION, 2013, 21 (02) : A27 - A27
  • [30] Skin Pigmentation and Pulse Oximeter Accuracy in the Intensive Care Unit: A Pilot Prospective Study
    Fawzy, Ashraf
    Ali, Harith
    Dziedzic, Peter H.
    Potu, Niteesh
    Calvillo, Eusebia
    Golden, Sherita H.
    Iwashyna, Theodore J.
    Suarez, Jose I.
    Hager, David N.
    Garibaldi, Brian T.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 210 (03) : 355 - 358