Hemodynamic Study of Cerebral Arteriovenous Malformation: Newtonian and Non-Newtonian Blood Flow

被引:0
|
作者
Ganjkhanlou, Mohammad Reza [1 ]
Shahidian, Azadeh [1 ]
Shahmohammadi, Mohammad Reza [2 ]
机构
[1] KN Toosi Univ Technol, Shahid Beheshti Univ Med Sci, Dept Mech Engn, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Funct Neurosurg Res Ctr, Shohada Tajrish Comprehens Neurosurg Ctr Excellenc, Tehran, Iran
关键词
Angiographic images; Arteriovenous malformation; Draining veins; Embolization; Feeding artery;
D O I
10.1016/j.wneu.2024.01.159
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
- OBJECTIVE: Arteriovenous malformation is a disease of the vascular system that occurs mainly in the cerebral arteries and spine. Numerical simulation as a powerful method is used to investigate the Cerebral Arteriovenous Malformation hemodynamic after occlusion of the abnormality step by step by embolization.- METHODS: The computed tomography (CT) Angiographic imaging data of 2 patients are used and a geometric model is extracted by the Mimics software. Numerical simulation of blood flow is performed in both Newtonian and nonNewtonian models. The Navier eStokes and continuity governing equations are solved by a finite element method using the COMSOL Multiphysics software (the commercial computational fluid dynamics (CFD) simulation software). To validate the numerical results, the real data on blood flow rate in the feeding artery and draining veins are used, as well as angiographic images at different times.- RESULTS: Regarding the comparison of pressure contours for different occlusions of 0, 30, 50, and 90%, by increasing the amount of occlusion in the nidus, there is an increase in the blood pressure. Regarding the comparison of the blood flow velocity in the feeding artery, draining veins, and inside the AVM nidus for Newtonian and nonNewtonian models, there is a significant difference between these 2 simulations in vessels with smaller dimensions (such as vessels inside the nidus).- CONCLUSIONS: By increasing the amount of nidus occlusion, the blood pressure is increased, so the blood supply process is better. According to a significant difference between the Newtonian and non-Newtonian simulations in vessels with smaller dimensions (such as vessels inside the nidus), therefore, non-Newtonian simulation should be done for different occlusions of 30, 50, and 90%.
引用
收藏
页码:E317 / E341
页数:25
相关论文
共 50 条
  • [31] NON-NEWTONIAN FLOW IN ANNULI
    FREDRICKSON, AG
    BIRD, RB
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1958, 50 (03): : 347 - 352
  • [32] COMMENT ON NON-NEWTONIAN FLOW
    STEVERDING, B
    AIAA JOURNAL, 1964, 2 (12) : 2231 - 2232
  • [33] AN ANALOGUE FOR NON-NEWTONIAN FLOW
    SKINNER, RH
    INSTRUMENT PRACTICE, 1968, 22 (11): : 929 - &
  • [34] NON-NEWTONIAN FLOW - REPLY
    WELLS, CS
    AIAA JOURNAL, 1964, 2 (12) : 2232 - 2232
  • [35] Effects of stenoses on non-Newtonian flow of blood in blood vessels
    Prakash, Om
    Makinde, O. D.
    Singh, S. P.
    Jain, Nidhi
    Kumar, Devendra
    INTERNATIONAL JOURNAL OF BIOMATHEMATICS, 2015, 8 (01)
  • [36] Flow Analysis of Non-Newtonian Blood in a Magnetohydrodynamic Pump
    Shahidian, A.
    Ghassemi, M.
    Khorasanizade, S.
    Abdollahzade, A.
    Ahmadi, G.
    IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (06) : 2667 - 2670
  • [37] Study of Non-Newtonian Blood Flow of Jeffrey Fluid in an Elastic Tube
    Sreenadh, S.
    Sumalatha, B.
    Srinivas, A. N. S.
    JOURNAL OF APPLIED FLUID MECHANICS, 2020, 13 (06) : 1807 - 1817
  • [38] TRANSPORT IN NON-NEWTONIAN FLOW
    GREIF, R
    KAPPESSE.R
    CORNET, I
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1972, 119 (06) : 717 - &
  • [39] Flow of a non-Newtonian fluid
    Pridanov, V. G.
    Khonichev, V. I.
    TECHNICAL PHYSICS, 2012, 57 (11) : 1475 - 1478
  • [40] EFFECTS OF STENOSIS ON NON-NEWTONIAN FLOW OF THE BLOOD IN AN ARTERY
    SHUKLA, JB
    PARIHAR, RS
    RAO, BRP
    BULLETIN OF MATHEMATICAL BIOLOGY, 1980, 42 (03) : 283 - 294