One-Shot Estimation of Epistemic Uncertainty in Deep Learning Image Formation with Application to High-Quality Cone-Beam CT Reconstruction

被引:0
|
作者
Liu, Stephen Z. [1 ]
Vagdargi, Prasad [2 ]
Jones, Craig K. [2 ]
Luciano, Mark [3 ]
Anderson, William S. [3 ]
Helm, Patrick A. [4 ]
Uneri, Ali [1 ]
Siewerdsen, Jeffrey H. [1 ,5 ]
Zbijewski, Wojciech [1 ]
Sisniega, Alejandro [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ Hosp, Dept Neurosurg, Baltimore, MD 21205 USA
[4] Medtronic Plc, Littleton, MA 01460 USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
来源
MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1 | 2024年 / 12925卷
关键词
deep learning; image synthesis; uncertainty; Monte Carlo dropout; moment propagation; image reconstruction cone-beam CT; artifact correction;
D O I
10.1117/12.3006934
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Purpose: Deep Learning (DL) image synthesis has gained increasing popularity for the reconstruction of CT and cone-beam CT (CBCT) images, especially in combination with physically-principled reconstruction algorithms. However, DL synthesis is challenged by the generalizability of training data and noise in the trained model. Epistemic uncertainty has proven as an efficient way of quantifying erroneous synthesis in the presence of out-of-domain features, but its estimation with Monte Carlo (MC) dropout requires a large number of inference runs, variable as a function of the particular uncertain feature. We propose a single-pass method - the Moment Propagation Model - which approximates the MC dropout by analytically propagating the statistical moments through the network layers, removing the need for multiple inferences and removing errors in estimations from insufficient dropout realizations. Methods: The proposed approach jointly computes the change of the expectation and the variance of the input (first two statistical moments) through each network layer, where each moment undergoes a different numerical transformation. The expectation is initialized as the network input; the variance is solely introduced at dropout layers, modeled as a Bernoulli process. The method was evaluated using a 3D Bayesian conditional generative adversarial network (GAN) for synthesis of high-quality head MDCT from low-quality intraoperative CBCT reconstructions. 20 pairs of measured MDCT volumes (120 kV, 400-550 mAs) depicting normal head anatomy, and simulated CBCT volumes (100-120 kV, 32-200 mAs) were used for training. Scatter, beam-hardening, detector lag and glare were added to the simulated CBCT and were corrected (assuming unknown) prior to reconstruction. Epistemic uncertainty was estimated for 30 heads (outside of the training set) containing simulated brain lesions using the proposed single-pass propagation model, and results were compared to the standard 200-pass dropout approach. Image quality and quantitative accuracy of the estimated uncertainty of lesions and other anatomical sites were further evaluated. Results: The proposed propagation model captured >2 HU increase in epistemic uncertainty caused by various hyper- and hypo-density lesions, with <0.31 HU error over the brain compared to the reference MC dropout result at 200 inferences and <0.1 HU difference to a converged MC dropout estimate at 100 inference passes. These findings indicate a potential 100-fold increase in computational efficiency of neural network uncertainty estimation. Conclusions: The proposed moment propagation model is able to achieve accurate quantification of epistemic uncertainty in a single network pass and is an efficient alternative to conventional MC dropout.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Development and Clinical Translation of a Cone-Beam CT Scanner for High-Quality Imaging of Intracranial Hemorrhage
    Sisniega, A.
    Xu, J.
    Dang, H.
    Zbijewski, W.
    Stayman, J. W.
    Mow, M.
    Koliatsos, V. E.
    Aygun, N.
    Wang, X.
    Foos, D. H.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [22] GPU-based 3D cone-beam CT image reconstruction: application to micro CT
    Zhao, Xing
    Bian, Junguo
    Sidky, Emil Y.
    Cho, Seungryong
    Zhang, Peng
    Pan, Xiaochuan
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3922 - +
  • [23] Improve 3D cone-beam CT reconstruction by slice-wise deep learning
    Yang, Hongkai
    Liang, Kaichao
    Zhang, Li
    Kang, Kejun
    Xing, Yuxiang
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [24] Improved image quality and beam stability for a high contrast imaging beam line used for megavoltage cone-beam CT
    Wu, V.
    Faddegon, B. A.
    Bani-Hashemi, A.
    Gangadharan, B.
    Morin, O.
    Pouliot, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S633 - S633
  • [25] Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy
    Wu, T. -H.
    Liang, C. -H.
    Wu, J. -K.
    Lien, C. -Y.
    Yang, B. -H.
    Huang, Y. -H.
    Lee, J. J. S.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [26] Evaluation of image quality for different kV cone-beam CT acquisition and reconstruction methods in the head and neck region
    Elstrom, Ulrik V.
    Muren, Ludvig P.
    Petersen, Jorgen B. B.
    Grau, Cai
    ACTA ONCOLOGICA, 2011, 50 (06) : 908 - 917
  • [27] High Quality and Low Dose Cone-beam CT Imaging with Anisotropic Regularized FDK Reconstruction Algorithm
    Lee, H.
    Lee, R.
    Suh, T.
    Jeong, W.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S70 - S70
  • [28] Multi-resolution statistical image reconstruction for mitigation of truncation effects: application to cone-beam CT of the head
    Dang, Hao
    Stayman, J. Webster
    Sisniega, Alejandro
    Zbijewski, Wojciech
    Xu, Jennifer
    Wang, Xiaohui
    Foos, David H.
    Aygun, Nafi
    Koliatsos, Vassilis E.
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02): : 539 - 559
  • [29] Digital reconstruction of high-quality daily 4D cone-beam CT images using prior knowledge of anatomy and respiratory motion
    Zhang, Yongbin
    Yang, Jinzhong
    Zhang, Lifei
    Court, Laurence E.
    Gao, Song
    Balter, Peter A.
    Dong, Lei
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 40 : 30 - 38
  • [30] JUNIOR INVESTIGATOR WINNER - Low-Dose C-Arm Cone-Beam CT with Model-Based Image Reconstruction for High-Quality Guidance of Neurosurgical Intervention
    Wang, A.
    Stayman, J.
    Otake, Y.
    Gallia, G.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 526 - 526