One-Shot Estimation of Epistemic Uncertainty in Deep Learning Image Formation with Application to High-Quality Cone-Beam CT Reconstruction

被引:0
|
作者
Liu, Stephen Z. [1 ]
Vagdargi, Prasad [2 ]
Jones, Craig K. [2 ]
Luciano, Mark [3 ]
Anderson, William S. [3 ]
Helm, Patrick A. [4 ]
Uneri, Ali [1 ]
Siewerdsen, Jeffrey H. [1 ,5 ]
Zbijewski, Wojciech [1 ]
Sisniega, Alejandro [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ Hosp, Dept Neurosurg, Baltimore, MD 21205 USA
[4] Medtronic Plc, Littleton, MA 01460 USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
deep learning; image synthesis; uncertainty; Monte Carlo dropout; moment propagation; image reconstruction cone-beam CT; artifact correction;
D O I
10.1117/12.3006934
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Purpose: Deep Learning (DL) image synthesis has gained increasing popularity for the reconstruction of CT and cone-beam CT (CBCT) images, especially in combination with physically-principled reconstruction algorithms. However, DL synthesis is challenged by the generalizability of training data and noise in the trained model. Epistemic uncertainty has proven as an efficient way of quantifying erroneous synthesis in the presence of out-of-domain features, but its estimation with Monte Carlo (MC) dropout requires a large number of inference runs, variable as a function of the particular uncertain feature. We propose a single-pass method - the Moment Propagation Model - which approximates the MC dropout by analytically propagating the statistical moments through the network layers, removing the need for multiple inferences and removing errors in estimations from insufficient dropout realizations. Methods: The proposed approach jointly computes the change of the expectation and the variance of the input (first two statistical moments) through each network layer, where each moment undergoes a different numerical transformation. The expectation is initialized as the network input; the variance is solely introduced at dropout layers, modeled as a Bernoulli process. The method was evaluated using a 3D Bayesian conditional generative adversarial network (GAN) for synthesis of high-quality head MDCT from low-quality intraoperative CBCT reconstructions. 20 pairs of measured MDCT volumes (120 kV, 400-550 mAs) depicting normal head anatomy, and simulated CBCT volumes (100-120 kV, 32-200 mAs) were used for training. Scatter, beam-hardening, detector lag and glare were added to the simulated CBCT and were corrected (assuming unknown) prior to reconstruction. Epistemic uncertainty was estimated for 30 heads (outside of the training set) containing simulated brain lesions using the proposed single-pass propagation model, and results were compared to the standard 200-pass dropout approach. Image quality and quantitative accuracy of the estimated uncertainty of lesions and other anatomical sites were further evaluated. Results: The proposed propagation model captured >2 HU increase in epistemic uncertainty caused by various hyper- and hypo-density lesions, with <0.31 HU error over the brain compared to the reference MC dropout result at 200 inferences and <0.1 HU difference to a converged MC dropout estimate at 100 inference passes. These findings indicate a potential 100-fold increase in computational efficiency of neural network uncertainty estimation. Conclusions: The proposed moment propagation model is able to achieve accurate quantification of epistemic uncertainty in a single network pass and is an efficient alternative to conventional MC dropout.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Task-based statistical image reconstruction for high-quality cone-beam CT
    Dang, Hao
    Stayman, J. Webster
    Xu, Jennifer
    Zbijewski, Wojciech
    Sisniega, Alejandro
    Mow, Michael
    Wang, Xiaohui
    Foos, David H.
    Aygun, Nafi
    Koliatsos, Vassilis E.
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (22): : 8693 - 8719
  • [2] Image Quality Improvement in Cone-Beam CT Using Deep Learning
    Lei, Yang
    Wang, Tonghe
    Harms, Joseph
    Shafai-Erfani, Ghazal
    Dong, Xue
    Zhou, Jun
    Patel, Pretesh
    Tang, Xiangyang
    Liu, Tian
    Curran, Walter J.
    Higgins, Kristin
    Yang, Xiaofeng
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [3] One-Shot Uncertainty Estimation for Deep Network Based Image Segmentation
    Min, Y.
    Ruan, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E433 - E433
  • [4] High-quality image reconstruction from exterior helical cone-beam CT data for NDE of industrial pipelines
    Guo, Jiqiang
    Zeng, Li
    Liu, Baodong
    INSIGHT, 2011, 53 (10) : 534 - 541
  • [5] Regularization Design for High-Quality Cone-Beam CT of Intracranial Hemorrhage using Statistical Reconstruction
    Dang, H.
    Stayman, J. W.
    Xu, J.
    Sisniega, A.
    Zbijewski, W.
    Wang, X.
    Foos, D. H.
    Aygun, N.
    Koliatsos, V. E.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [6] A New Reconstruction Algorithm for Improved Cone-Beam CT Image Quality
    Li, T.
    Li, X.
    Yang, Y.
    Heron, D.
    Huq, M.
    MEDICAL PHYSICS, 2009, 36 (06) : 2746 - +
  • [7] Statistical reconstruction for cone-beam CT with a post-artifact-correction noise model: application to high-quality head imaging
    Dang, H.
    Stayman, J. W.
    Sisniega, A.
    Xu, J.
    Zbijewski, W.
    Wang, X.
    Foos, D. H.
    Aygun, N.
    Koliatsos, V. E.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (16): : 6153 - 6175
  • [8] Novel Algorithms for High-Quality Diagnostic and On-Board Cone-Beam CT
    Sisniega, Alejandro
    Sisniega, A.
    Kachelriess, M.
    Wang, A.
    Rong, Y.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [9] Novel approximate approach for high-quality image reconstruction in helical cone beam CT at arbitrary pitch
    Schaller, S
    Stierstorfer, K
    Bruder, H
    Kachelriess, M
    Flohr, T
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 113 - 127
  • [10] Application of dual-energy techniques to helical, cone-beam CT image reconstruction
    Sidky, E
    Zou, Y
    Pan, X
    MEDICAL PHYSICS, 2003, 30 (06) : 1408 - 1408