Compression strength of aged built-up column with vanished lacing bars

被引:1
|
作者
Miyoshi, T. [1 ]
Nakakita, T. [1 ]
Iwatsubo, K. [2 ]
Takai, T. [3 ]
Tamada, K. [4 ]
机构
[1] Akashi Coll, Dept Civil Engn, Natl Inst Tech KOSEN, Akashi, Hyogo, Japan
[2] Kumamoto Coll, Prod Syst Engn Crs, Natl Inst Tech KOSEN, Yatsushiro, Kumamoto, Japan
[3] Kyushu Inst Tech, Dept Civil & Architecture Engn, Kitakyushu, Fukuoka, Japan
[4] Maizuru Coll, Dept Civil Engn & Arch, Natl Inst Tech KOSEN, Maizuru, Kyoto, Japan
关键词
D O I
10.1201/9781003348450-155
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Recently, Japanese aged built-up members have lost their lacing bars due to corrosion. However, remaining strength of the built-up column with vanished lacing bars has not been clarified yet. In addition, residual stress of channel shaped steel which consists built-up column has not made sufficiently clear. The authors measured residual stress distribution of channel shaped steel, which was removed from an aged steel truss bridge. Moreover, the authors numerically calculated ultimate behavior of the built-up column with vanished lacing bars using finite element method. As a result, it is found that residual stress magnitude of the channel shaped steel is small compared to that of welded member, vanishment of lacing bars does not cause significant reduction of the compression strength and column strength curve given in Japan Specifications for Highway Bridges can be used to estimate its remaining strength conservatively.
引用
收藏
页码:331 / 332
页数:2
相关论文
共 50 条
  • [41] Determination of Buckling Behavior of Web-Stiffened Cold-Formed Steel Built-Up Column under Axial Compression
    Mohan, Muthuraman
    Ramachandran, Anuradha
    Amran, Mugahed
    Borovkov, Aleksey
    MATERIALS, 2022, 15 (09)
  • [42] Nonlinear response of high-strength cold-formed steel built-up members subject to cyclic compression
    Kho, Shin Rui
    Ng, Adeline Ling Ying
    Looi, Daniel Ting Wee
    Lau, Hieng Ho
    Gad, Emad
    Roy, Krishanu
    THIN-WALLED STRUCTURES, 2025, 212
  • [43] Study of axial compression strength of cold-formed thin-walled built-up steel box columns
    Du, Zhaoyu (ivydzy@hotmail.com), 1600, Science Press (35):
  • [44] Experimental testing of cold-formed built-up members in pure compression
    Biggs, Kenneth A.
    Ramseyer, Chris
    Ree, Suhyun
    Kang, Thomas H. -K.
    STEEL AND COMPOSITE STRUCTURES, 2015, 18 (06): : 1331 - 1351
  • [45] Experimental investigation of built-up double-Z members in bending and compression
    Georgieva, Iveta
    Schueremans, Luc
    Pyl, Lincy
    Vandewalle, Lucie
    THIN-WALLED STRUCTURES, 2012, 53 : 48 - 57
  • [46] Numerical study of built-up double-Z members in bending and compression
    Georgieva, Iveta
    Schueremans, Luc
    Pyl, Lincy
    Vandewalle, Lucie
    THIN-WALLED STRUCTURES, 2012, 60 : 85 - 97
  • [47] Closed built-up cold-formed steel columns under compression
    Craveiro, Hélder D.
    Rahnavard, Rohola
    Santiago, Aldina
    Laím, Luís
    Simões, Rui
    ce/papers, 2023, 6 (3-4) : 1941 - 1946
  • [48] Slenderness ratio of main members between interconnectors of built-up compression members
    Temple, MC
    Elmahdy, GM
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1996, 23 (06) : 1295 - 1304
  • [49] Experimental Investigation into the Behaviour of CFS Built-Up Channels Subjected to Axial Compression
    Roy, Krishanu
    Ting, Tina Chui Huon
    Lau, Hieng Ho
    Lim, James B. P.
    ADVANCES IN TRANSPORTATION ENGINEERING, 2019, 34 : 89 - 105
  • [50] Flexural strength of cold-formed steel built-up box sections
    Xu, Lei
    Sultana, Papia
    Zhou, Xuhong
    THIN-WALLED STRUCTURES, 2009, 47 (6-7) : 807 - 815