Compression strength of aged built-up column with vanished lacing bars

被引:1
|
作者
Miyoshi, T. [1 ]
Nakakita, T. [1 ]
Iwatsubo, K. [2 ]
Takai, T. [3 ]
Tamada, K. [4 ]
机构
[1] Akashi Coll, Dept Civil Engn, Natl Inst Tech KOSEN, Akashi, Hyogo, Japan
[2] Kumamoto Coll, Prod Syst Engn Crs, Natl Inst Tech KOSEN, Yatsushiro, Kumamoto, Japan
[3] Kyushu Inst Tech, Dept Civil & Architecture Engn, Kitakyushu, Fukuoka, Japan
[4] Maizuru Coll, Dept Civil Engn & Arch, Natl Inst Tech KOSEN, Maizuru, Kyoto, Japan
关键词
D O I
10.1201/9781003348450-155
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Recently, Japanese aged built-up members have lost their lacing bars due to corrosion. However, remaining strength of the built-up column with vanished lacing bars has not been clarified yet. In addition, residual stress of channel shaped steel which consists built-up column has not made sufficiently clear. The authors measured residual stress distribution of channel shaped steel, which was removed from an aged steel truss bridge. Moreover, the authors numerically calculated ultimate behavior of the built-up column with vanished lacing bars using finite element method. As a result, it is found that residual stress magnitude of the channel shaped steel is small compared to that of welded member, vanishment of lacing bars does not cause significant reduction of the compression strength and column strength curve given in Japan Specifications for Highway Bridges can be used to estimate its remaining strength conservatively.
引用
收藏
页码:331 / 332
页数:2
相关论文
共 50 条
  • [1] Compression strength of aged built-up column with vanished lacing bars
    Miyoshi, T.
    Nakakita, T.
    Iwatsubo, K.
    Takai, T.
    Tamada, K.
    CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 950 - 955
  • [2] Global buckling strength of built-up cold-formed steel column under compression
    Kobashi, T.
    Shimizu, N.
    STABILITY AND DUCTILITY OF STEEL STRUCTURES 2019, 2019, : 605 - 613
  • [3] Numerical Analysis of the Load-carrying Capacity of Built-up Columns with Damaged or Missing Lacing Bars
    Takai, Toshikazu
    Furuichi, Taiyo
    Miyoshi, Takao
    Iwatsubo, Kaname
    Tamada, Kazuya
    Morimoto, Kenta
    PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY, 2025, 33 : 13 - 25
  • [4] AN ANALYTICAL CRITERION FOR BUCKLING STRENGTH OF BUILT-UP COMPRESSION MEMBERS
    ASLANI, F
    GOEL, SC
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1991, 28 (04): : 159 - 168
  • [5] Effect of compound buckling on compression strength of built-up members
    Duan, Lian
    Reno, Mark
    Uang, Chia-Ming
    Engineering Journal, 2002, 39 (01): : 30 - 37
  • [6] Effect of compound buckling on compression strength of built-up members
    Duan, L
    Reno, M
    Uang, CM
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 2002, 39 (01): : 30 - 37
  • [8] ANALYTICAL CRITERIA FOR STITCH STRENGTH OF BUILT-UP COMPRESSION MEMBERS
    ASLANI, F
    GOEL, SC
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1992, 29 (03): : 102 - 110
  • [9] Notes on Determining Required Connector Strength in Built-up Compression Members
    Geschwindner, Louis F.
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2020, 57 (03): : 215 - 220
  • [10] Notes on determining required connector strength in built-up compression members
    Geschwindner, Louis F.
    Engineering Journal, 2020, 57 (03): : 215 - 220